Time 1 - Door Time On Stop (P681/P691)
Door open time on stop, internal/external buttons.
Time 2 - Door Time at Photocell Activation and Overload (P682/P692)
Door open time at overload. Normal protection in door opening - photocells, momentary arm etc.
Time 3 uses same value as Time 2.
Door Time 4 - Door Time at Loading (P683/P693)
Door open time at loading.
Changetime (P684/P694)
Time between opening and closing and between closing and opening. The time is provided so that
there is time between the opening contactor switching and the closing contactor engaging and vice
versa.
Maxtime open/close (P685/P695)
Controls the maximum close time or maximum cycle time from full open to full close. Set the active
time for open/close.
Input 1 (DOLA1) (P686/P696)
See Section Door I/O Ports below.
Input 4 (DOLA4) (P687/P697)
See Section Door I/O Ports below.
Door opening on arrival at floor (P688/P698)
Controlshowthedoorwillopenwhentheliftarriveatafloor.Offdisablesautomaticopening,at
stopopensdoorwhenlifthasreachedthefloorandstopped,earlyopensthedoorbeforethelift
has reached full stop (early is only available if the lift has zone system).
Parameters Side A/B
13.3.4
680/690
Type
Swingdoor, Telescopic, Telescopic/
Tunnel
681/691
Time 1
Stopping for Internal/External calls
682/692
Time 2
Overload of Photocells in Car Door
Opening
683/693
Door time 4
684/694
Changetime
685/695
Maxtime o/c
686/696
Input 1
Monostable, Bistable
687/697
Input 4
Monostable, Bistable, DOLs1 delayed
688/698
O. at arrival
Off, At stop, Early
Cabindoor
Door Opening (P700)
Controls the door opening of the car. Time limited door opening for door control with two inputs.
Continuous for door controls with one input.
Opening Time (P701)
Sets the opening time for P700. Only valid for Time Limited door opening.