17.4.1
Status
System information such as temperature, voltage, back-up condenser, external 24 V, processor
utilisation and phase monitor.
Options
17.4.2
Temperature
Temperature in the shaft
Vcc
CPU voltage after the PTC resistor
Unreg.
CPU voltage before the PTC resistor
Backup C
Capacitor voltage for backup memory
External 24V
Voltage for I/O
Utilization
Processor load
Phasedet.
Status of the phase detection relays
Angle
Status of the angle
Voltage
Status of the 3-phase voltage
Floor Count
Informationonfloorcounterandflagcounterorpositioninmm,absoluteandrelativetothenearest
floor.
Options
17.4.3
Floor
Floor number
Counter
On/Off
Down counter
Down Counter in mm
Up counter
Up Counter in mm
Landings
Information on lifts in the group. Lift status, position, direction, whether parked and side (for lifts
with tunnel).
Figure 17.1 Landings
Displays lift information.
Symbols used:
P = Parked
A = Side A
B = Side B
X = Lift Out of Service
Flashing arrow = Moving direction of lift
Static arrow = Possible directions of lift
17.5
Tools
17.5.1
Auto Tuning
Engages output relays for control of frequency converters so auto tuning can be run on frequency
converter. Shows which relays should be engaged during start value. Activate function with
active. Stop function with stop.
Options
Start value
Activate
Stop
S3 Control Unit User Guide
51
Rev B2 - May 2009