5.2 Troubleshooting Guide (7) Calendar IC Stop Error Code 1110 : Calendar IC R/W stop 1111 : Calendar IC stop Possible cause of the malfunction 1. Count up of the calendar IC is stopped. 2. Calendar IC of the CPU card failure Countermeasures Confirm the time displayed on the PT. No Is the displayed time correct? Yes Is the time counting up? Yes No Set the time from PT, maintenance terminal. Is the time set correctly and count ing up correctly? Yes No Replace the CPU card.* End Note 294 *It is recommended to have a current copy of the programme on disc to facilitate accurate and rapid recovery. Troubleshooting