5.2 Troubleshooting Guide (2) TSW clock down Error Code 1100 : TSW clock down Possible cause of the malfunction 1. TSW card connexion error 2. TSW card clock link failure Countermeasures After confirming the TSW card connexion, press the RESET button. Is the trouble registered in the Error Log ? Yes No ls an Extension/CO call possible? Yes No Replace the TSW card. No change in condition OK Replace the Shelf. End Note If the TSW clock malfunction occurs: 1. Calling becomes impossible. 2. Power Failure Transfer will be activated. Troubleshooting 289