S T E K O P SA Manufacturing: ul. Mołdawska 9, 02-127 Warszawa kol. Porosły 52, 16-070 Choroszcz tel. 085 748 90 00, fax 085 748 90 38 e-mail: [email protected] 3. HF400 sensor functions. The basic function of HF400 sensor is to detect an intruder trespassing one of two detection zones. The sensor provides for defining the minimal body weight and the range of speeds of an intruder who would trigger an alarm. Additionally there is a possibility to define the acceptable speed of variation of received signal. In this way, it is possible do limit the influence of external disturbances (e.g. atmospheric discharges) on alarm signaling. HF400 sensor is equipped with an automatic adaptation to external conditions function (e.g. variations in soil conductivity provoked by rain) and with diagnostic functions. Automatic adjustment to environmental conditions includes correcting signal power level of the transmitter, amplification of the receiver circuits and adjustment of preprogrammed detection thresholds. The last correction is based on measurement of calibration impulse generated cyclically by the sensor. Device diagnostic functions comprise monitoring of operating parameters vital to intruder detection: i.e. power supply voltages in different circuits, signal power level of the transmitter, received signal level, amplification of the receiver circuits, integrity of active cables, internal temperature of the sensor. Based on the parameter divergence from the preprogrammed value, this new value is either interpreted as „sensor not ready” or a physical damage of the sensor components. Communications functions constitute the third group of sensor features. These enable to send messages about events, remotely control the sensor, real-time preview received signal level and all the stages of its processing (independently in amplitude and phase variation measuring circuits), to program operating parameters and to update the system software. The last group of sensor’s features comprises the functions enabling HF400 sensor to interface with other systems. The sensor is equipped with 8 general purpose programmed parametric inputs and 8 programmed relay outputs. The state of HF400 inputs can be previewed by its controller unit and the state of relay outputs depends on a preprogrammed configuration. They can be triggered by a defined event or their state can be entirely controlled by the system controller unit. • HF400 sensor function list: Intruder detection o Support up to 2 independent detection zone of maximal length of 200 m by each HF400 module. o Intruder detection based on simultaneous analysis of received signal amplitude and phase variations. o Detection of objects above a predefined body weight (value range between 20 and 100 kg). o Detection of objects moving with speed of 25 cm/s to 15 m/s (exact value range is programmed). o Intruder detection independently of his way of moving (i.e. running, walking, crawling etc.). o Detected intruder speed estimation. HF400 version 3.1 Installation manual Page 8 of 67