Download VARISPEED V7 USER'S MANUAL
Transcript
Example for 200 V Class Motors Cooling Effect General-purpose Effective when operated at 50/60 Hz from commercial power supply Torque Characteristics 60 s Short-term Continuous rating Torque (%) Electronic Thermal Overload An error (motor overload protection) occurs when continuously operated at 50/ 60 Hz or less at 100% load. 50 Operation Frequency (Hz) Base Frequency 60 Hz (V/f for 50 Hz, 220 V Input Voltage) For low-speed operation, torque must be limited in order to stop motor temperature rise. Inverter Motor Effective even when operated at low speed (approx. 6 Hz) 60 s Short-term Continuous rating Torque (%) 50 Operation Frequency (Hz) Base Frequency 60 Hz (V/f for 50 Hz, 220 V Input Voltage) Use an Inverter motor for continuous operation at low speed. 130 Electronic thermal overload protection is not activated even for continuous operation at 50/60 Hz or less at a 100% load.