Download Installation / Troubleshooting Manual
Transcript
TROUBLESHOOTING Series 7500/7600 8500/8600 9500/9600 Multifunction Instrument BEFORE CALLING FOR ASSISTANCE, COMPLETE THESE TROUBLESHOOTING CHECKS AND RECORD YOUR FINDINGS. TECHNICAL SUPPORT REQUIRES THIS INFORMATION BEFORE A RETURN AUTHORIZATION WILL BE ISSUED. IT TAKES ABOUT 20 MINUTES AND IS VERY IMPORTANT IN ANALYZING SYSTEM PROBLEMS. Before starting, record Instrument model number and switch settings. MODEL # ________________________ 0 0 BLACK RED F 0 1 A 16 15 14 13 12 UPPER BLACK________ RED________ GREEN________ 7 6 5 BLACK RED 0 4 GREEN 0 2 3 4 5 D C B 8 0 GREEN E SERIAL # ________________________ 0 0 9 8 7 6 11 10 9 3 2 1 BACK OF INSTRUMENT LOWER BLACK SWITCH 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 BACK OF INSTRUMENT LOWER BLACK or RECESSED ARROW________ FAULT PROBABLE CAUSE SEE SECTION: Blank LCD Display No Back-Lighting High or Low Totalizer reading. Over 10%. Wiring Wiring Calibration Incorrect flow sensor Incorrect switch settings Vacuum leak Vacuum leak / Pulsations Wiring Sensor orientation Wiring Calibration Continuity In-synch with engine or Glen Denning cable whip Wiring /Instrument failure Sensor Failure Vacuum Leak Incorrect switch settings Sensor orientation Sections II, III Sections III Calibration sheet Operations sheet Calibration sheet Section IX Sections VIII, IX, X Sections II, V, VI Installation sheet, Section IV Installation sheet, Section II Calibration sheet Section VI Fluctuating GPH Readings No GPH or Totalizer Readings High, Low or No Tachometer Reading No Forward or Return Sensor Readings High Forward or Return Sensor Readings Section VII Sections I, II, IV, V, VI Section I, IV Section IX Calibration sheet Section XI I. DIAGNOSTIC TEST: 1. Start engine(s). For 2 seconds after powering up, the Instrument will show all 8s. During this time, quickly cycle the TotalizerReset Switch from its’ run position to reset and back at least twice. This puts the Instrument into Show Switches Mode for 20 seconds. Record these readings below. HOURS: ____________:_____________ RPM: ____________________ GPH: ________________________ GALLONS: _______________ After 20 seconds, the Instrument automatically goes into diagnostic mode. A minus sign (--) in the GALLONS window indicates when this occurs. The Instrument remains in diagnostic mode until power is secured. 1/17/2002 FloScan Instrument Company, Inc. 3016 NE Blakeley Street, Seattle, WA 98105 7000-074-00C Tel: (206) 524-6625 Fax: (206) 523-4961 email: [email protected] http://www.floscan.com