Download Operating instructions OSRAM OUTDOOR sensor
Transcript
Control principle (normal mode) Operation (cont.) Luminaire OFF Motion? no yes Artificial light required? no yes Luminaire ON Luminaire ON 5 s - 30 min Motion? no Luminaire OFF no Luminaire OFF yes ja Artificial light required? yes Setting the light switching theshold Setting of the light switching threshold at which the load is switched on or off as a function of the measured light value (default setting: 7 lux). If the light switching threshold is deactivated, the connected load is switched on whenever motion is detected, independent of the measured light value. Changing the light switching threshold Press button S1 briefly. The current light value measurement is stored as the light switching threshold. Confirmation: The LED flashes 1x. S1 S2 Deactivating/activating the light switching threshold Press button S1 for at least 2 s. Confirmation: The LED flashes 2x. When the light switching threshold is deactivated, the LED flashes briefly every 5 s. Setting the delay The switch-off delay time in normal mode when no motion is detected (default setting: 2 min). Press button S2 briefly. The LED begins flashing. Press button S2 again briefly after a delay of T (5 s – 30 min). The LED goes out. T is stored as the delay time. Page 2 of 4