FX3U Series Programmable Controllers 4 Specifications, External Dimensions and Terminal Layout (Main Units) User’s Manual - Hardware Edition 1 Product life of relay contacts The standard life of the contact used for conductive AC loads, such as contactors and solenoid valves, is 500,000 times at 20 VA. The following table shows the approximate life of the relay based on the results of our life test. Test condition: 1 sec. ON / 1 sec.OFF Example of applicable loads (Magnetic switch manufactured by our company) 0.2 A / 100V AC 20 VA 0.1 A / 200V AC 3,000,000 times S-K10 to S-K95 0.35 A / 100V AC 0.17 A / 200V AC 1,000,000 times S-K100 to S-K150 200,000 times S-K180,S-K400 0.8 A / 100V AC 80 VA 0.4 A / 200V AC 3 Product Introduction 35 VA If rush overcurrent is shut off even under the above condition, the life of the relay contact is considerably decreased. Transistor output (sink type) The output numbers in the table indicate the main unit terminal numbers. "Y010 or more" means the numbers from Y010 to the largest number that the main unit has. (The output numbers of FX3U-16MT/ S are Y000 to Y007.) FX3U-16MT/ S FX3U-32MT/ S FX3U-48MT/ S FX3U-64MT/ S FX3U-80MT/ S FX3U-128MT/ES 8 points Connecting type Fixed terminal block (M3 screw) 16 points Output type/form 24 points 32 points 40 points 64 points 6 Removable terminal block (M3 screw) System Configuration Number of output points Transistor/sink output External power supply 5 to 30V DC Installation 0.1 mA or less/30V DC ON voltage 1.5 V or less − Min. load OFF→ON Y000 to Y002:5 µs or less/10 mA or more (5 to 24V DC) Y003 or more:0.2 ms or less/200 mA or more (at 24V DC) ON→OFF Y000 to Y002:5 µs or less/10 mA or more (5 to 24V DC) Y003 or more:0.2 ms or less/200 mA or more (at 24V DC) Circuit insulation Photocoupler insulation Display of output operation LED on panel lights when photocoupler is driven. 9 Preparation and Power Supply Wiring Response time 8 12W/24V DC Open circuit leakage current 7 Input/Output Nos., Unit Nos. 0.5A / point The total load current of resistance loads per common terminal should be the following value. → For details on the common terminal for each model, Resistance refer to the terminal block layout. load • 1 output point/common terminal: 0.5 A or less Max. load • 4 output points/common terminal: 0.8 A or less • 8 output points/common terminal: 1.6 A or less Inductive load 5 Version and Peripheral Devices Item Transistor output (sink) specifications 4 Specifications 4.4.3 2 Features and Part Names Contact life Load capacity Introduction 4.4.2 4.4 Output Specifications 10 Input Wiring 53