Download hu

Transcript
Operation
Operating displays and errors of MXA axis module
6
6.4
Operating displays and errors of MXA axis module
Table of displays
Description
State
Comment / action
Displays during boot process
Unit passes through several
states when loading the firmware (boot) to get ready for
operation.
•
•
•
Status: not ready.
Output stage is blocked.
No communication possible.
•
•
Waiting for boot process to finish.
Unit stays in this condition: Unit defective.
Displays of diverse unit statuses
No DC link voltage.
Check mains.
Supply module not ready for
operation.
Check supply module.
Axis module 24 V or internal
switched-mode power supply
module of axis not ready for
operation.
24 V check or unit defective.
Axis module in safe stop.
Flashing
•
•
•
Status: not ready.
Output stage is blocked.
Communication is possible.
Safety function activated.
•
•
Synchronization with bus is
incorrect. Process data processing not available.
•
•
•
•
The encoder evaluation is not
ready.
Flashing
Check bus connection.
Check synchronization setting at unit and
control.
Check process data settings at unit and control.
Check missing of a PDO.
Encoders are initialized.
Unit stays in this condition:
• No encoder selected.
• "Source of actual speed" parameter
shows an encoder that does not exist.
Displays during initialization processes (parameters will be reset to default values)
Basic initialization.
Initialization delivery status.
Initialization factory setting.
•
•
•
Status: not ready.
Output stage is blocked.
Communication is possible.
Waiting for initialization to finish.
Initialization customer-specific
set 1.
Initialization customer-specific
set 2.
162
Operating Instructions – MOVIAXIS® MX Multi-Axis Servo Inverter