Installation Signal bus cables to other SEW units - EtherCAT-based system bus 4 4.7 Signal bus cables to other SEW units - EtherCAT-based system bus [1] 0 1 0 1 0 1 [2] [3] [4] [5] [1] System bus connection cable [4] SEW stations with SEW EtherCAT interface [2] Output plug yellow [5] LAM switch • Switch setting 0: All axis modules except the last one • Switch setting 1: Last axis module in the system [3] Input plug green, RJ45 STOP Important: The DIP switch LAM [5] must be set to "1" at the last axis module in a system. At all other axis modules, it must be set to "0". The lengths of the pre-fabricated connection cables [1] are 0.75 m and 3 m. STOP Use only pre-fabricated cables from SEW-EURODRIVE (special assignment) for this connection. 72 Operating Instructions – MOVIAXIS® MX Multi-Axis Servo Inverter