Transcript
ENG Hot gas safety procedure for Slave offline (parameter A13) Type HF alarms In a Master/Slave network the multiplexed hot gas defrost is always synchronized by the Master. The safety procedure switches the Slave OFF if it is offline (no longer by the Master across the tLAN). The type HF HACCP alarm is generated following a power failure for an extended time (> 1 minute), if when power returns the temperature read by probe set for parameter AA exceeds the AH high temperature threshold. HFn indicates the number of type HF alarms activated. Par. A13 Description Hot gas safety procedure for Slave offline 0 = not enabled; 1 = enabled Def 0 Min 0 Max 1 UoM - Par. Description HFn Number of type HF alarms HF to HF2 Type HF HACCP alarms activated (press Set) y__ Alarm 1 to 3 - Year M__ Alarm 1 to 3 - Month d__ Alarm 1 to 3 – Day of the month h__ Alarm 1 to 3 – Hours n__ Alarm 1 to 3 – Minutes --Alarm 1 to 3 – Duration Tab. 9.g Alarm log (parameters HS0 to HS9) The alarm log can be displayed by accessing parameters HS0 to HS9, rather than using the procedure described in paragraph 9.3. Par. HS0 to 9 --h__ n__ --- Description Alarm 0 to 9 (press Set) Alarm 0 to 9 - Code Alarm 0 to 9 - Hours Alarm 0 to 9 – Minutes Alarm 0 to 9 - Duration Def 0 0 0 Min 0 0 0 Max 23 59 999 UoM hour min min Def 0 - Min 0 - Max 15 - UoM - 0 0 0 0 0 0 0 1 1 0 0 0 99 12 31 23 59 240 year month day hour minute minute Tab. 9.j Tab. 9.h AH S St 9.6 HACCP alarm parameters and activating monitoring t ON ALARM OFF t Type HA alarms black out The alarm queue can be displayed by accessing parameters HA to HA2, rather than using the procedure described in paragraph 9.4. The type HA alarm is generated if during normal operation the temperature read by the probe set for parameter AA exceeds the high temperature threshold for the time Ad+Htd. Consequently, compared to the normal high temperature alarm already signalled by the controller, the type HA HACCP alarm is delayed by a further time Htd specifically for HACCP recording. The order of alarms listed is progressive, HA is the most recent alarm. A maximum of 3 errors are saved, in a FIFO list (HA to HA2). HAn indicates the number of type HA alarms activated. Par. Ht0 HAn HA to HA2 y__ M__ d__ h__ n__ --Htd Description Def HACCP alarms present 0 Number of type HA alarms 0 Type HA HACCP alarms activated (press Set) Alarm 1 to 3 - Year Alarm 1 to 3 - Month Alarm 1 to 3 – Day of the month Alarm 1 to 3 – Hour Alarm 1 to 3 – Minutes Alarm 1 to 3 – Duration HACCP alarm delay 0 = monitoring disabled 0 0 0 0 0 0 0 Min 0 0 - Max 1 15 - UoM - 0 1 1 0 0 0 0 99 12 31 23 59 240 240 year month day hour minute minute Fig. 9.d Key S St AH Tab. 9.i AH S St t ON ALARM OFF t Ad Htd Fig. 9.c Key S St AH ALARM Ad Htd t Measurement probe Set point High temperature alarm threshold Type HA HACCP alarm Delay time for high and low temperature alarms HACCP alarm delay 0 = monitoring disabled Time MPXPRO - +0300055EN rel. 1.4 - 16.07.15 62 Measurement probe Set point High temperature alarm threshold ALARM t Type HF HACCP alarm Time