27 (70) User Manual M10 MultiController nvi_xDO_AlrmStop is 1, then the DO object is locked regardless of the value of nvi_xDO_AlrmStop. Locking Release Level Object locking release level. The value of this parameter defines the limit level for value field of nvi_xDO_AlrmStop variable, lower values releasing the object from standstill. To enable locking with value field, the state field of nvi_xDO_AlrmStop variable needs to be zero (0). 0...200 Invert This parameter inverts the state of the output network variable and the physical state of the object. Yes No NOTE! Object locking with nvi_xDO_AlrmStop variable functions also when the object is inverted. The state of the nvi_xDO_AlrmStop variable still needs to be zero for the object locking to work. Trigger Level (Value.State) The value field of nvi_xDO_Switch1/2 variable can be used to control the physical digital output by configuring this parameter with a desired trigger value, higher values changing the physical digital output into ON-state and lower into OFF-state. If the state field of this parameter is set to zero, then the object will be ON when the state of an nvi_xDO_Switch1/2 variable is 0 and OFF when the state is 1, and vice versa. Value 0…255 State 0…1 E.g. 200.01 = Value: 200, State: 1 Example: If the Trigger Level (value.state) parameter is set to 11.00, the DO will be in ON state whenever the value of an nvi_xDO_Switch1/2 is greater than 5.5, or the state of an nvi_xDO_Switch1/2 is 0. The object will be in OFF state when the value is less or equal to 5.5 and the state is 1. (AlarmStop ON) nvo_xDO_Switch value.active The influence of the object’s locking functionality on the output network variable. The value of this parameter is the value shown in nvo_xDO_Switch (state is 0) variable when the object is locked and this parameter is active (1). Value 0…200 Active 0…1 When this parameter is not active (0), the value of nvo_xDO_Switch follows that of the nvi_xDO_Switch1/2 variable (with a state of 0 if the object is locked). Example: If this parameter is set to 32.01 and the object is locked, then nvo_xDO_Switch will be 16.0 0. 4.4 PWM-Control (Normal) This function is mostly used in PWM-based heating and cooling control such as floor heating systems and cooling systems. The output capacity of the system is adjusted by altering the time the object is in ON-state during a configured duty cycle time. For example, a 40% output capacity is achieved with a 100 second duty cycle by keeping the object 40 seconds in ON-state and 60 seconds in OFF-state. LONIX LTD www.lonix.com Teollisuuskatu 33 FI-00510 Helsinki, Finland Tel. +358 9 349 9853 Fax +358 9 349 9863 VAT 1043054-9 Trade Reg.No. 678.356