7 Web page basics 7.1 Connecting to SM-Ethernet If you are using DHCP, all settings on the SM-Ethernet module will be configured by the network DHCP server, you can confirm this is working by checking the IP address has been correctly configured in parameters Pr MM.10 to Pr MM.13. In order to communicate, the PC must be on the same subnet as the drive or you must have a gateway specified for the host PC and the SM-Ethernet module. NOTE 7.1.1 If you are not using DHCP you will need to manually configure the address, subnet mask and default gateway (if you are connecting from a different subnet) see section 5.11 Setting the IP address on page 22. Making a connection To connect to SM-Ethernet, enter the address of the SM-Ethernet module (see section 5.11 Setting the IP address on page 22) into the browser window as follows: http://192.168.1.100 (this is the default address) Replacing the address (192.168.1.100) with the address of the SM-Ethernet module you wish to communicate with. NOTE 66 The default IP address when not using DHCP is 192.168.1.100. In order to communicate with this address your PC will need to be on the same subnet or have a gateway capable of reaching this address, additionally SM-Ethernet will also require a gateway configured to communicate with the PC in this case. www.controltechniques.com SM-Ethernet User Guide Issue: 6