Download User Guide - Antech Sales, Inc
Transcript
100/180 mm paperless GRAPHIC RECORDER: USER GUIDE 3.3.1 Access to Configuration 1 2 3 4 5 As shown in figure 3.3.1a, once the recorder has initialised, touch the current access level key Touch the ‘Logged out’ field and then touch ‘Engineer’ from the resulting picklist. Touch the blank Password area to call the keyboard display (see figure 3.3.1b). Touch <Numeric><1><0><0><OK> to enter the password ‘100’. The screen reverts to the ‘Home’ page. Operation of the Root key followed by a touch on the Operator key calls the top level page allowing access to the Archive, Save/Restore, Config, Security, Network and System areas described in section 4 below. 1 Touch Current access level key Group name Logged out Channel 1 0.2000 0.0000 11:52:59 05/04/05 0.4000 0.6000 0.8000 Login Select the required access level and enter the password if required. User Logged out Logged out Operator Engineer 3 0.0237V 1.0000 11:52:04 05/04/05 2 Touch 'logged out' area... ...then touch access level required. Service 11:49:24 05/04/05 Touch the password window when it appears, and enter the password. The Engineer level password is '100' when the unit is despatched from the factory. Passwords can be edited in 'Security' as described in section 4.4.1. The screen reverts to the home page, with the new access level displayed in the 'Current access level' key 11:46:44 05/04/05 Close Figure 3.3.1a Access to configuration Notes: 1. For units which have the Auditor 21CFR11 Option enabled, the default Operator password is ‘100’. Otherwise no password is required for default Operator level access. In either case the Operator access level password can be edited in ‘Security’ configuration. (Section 4.4.1.) 2. The login screen, above, can also be called by operating the Root menu, then ‘Operator’ then ‘Security’, then ‘Login’. In such a case, the screen reverts to the ‘Operator’ page rather than returning to the home page once login has been achieved. 3. Figure 3.3.1a shows ‘Login by user list’ which is the default method. If either Auditor option and/or the Security management option is enabled, an alternative procedure is possible where each user has to enter a name and associated password - i.e. there is no list of users/access levels to choose from. See section 4.4.2 (Management) for details. 4. For Active Directory users, a password expiry warning message (below) pops up on log-in, stating how many days remain before the password expires (configured at the Active Directory server). Warning Fred password expires in 2 days Ok User Guide Page 32 HA028910 Issue 8 Oct 10
Related documents
User Guide - The Online Instrumentation Company
Zebra Stripe Technical information
100 and 180 mm paperless graphic recorders User guide
180 mm secure graphic recorders User guide
100 mm graphics recorder User guide
Model 5100e 100 mm graphics recorder User guide - E
100 mm graphics recorder User guide
5100/5180 100 and 180 mm video-graphics recorders User guide
EUROTHERM - Enregistreurs dans papier 100mm
Sapphire PURE CrossFireX 890GX Motherboard User Manual
(RoHS) - AR Comunicación integral
TECHNICAL MANUAL Of VIA VX900H Chipset