This can generate EEDEAD, EECRC or EEBAD errors. Diag\Test\Moto This runs the tests for the Motor drive circuitry and then exits the test. No keys are used. This test is also run at power up. This can generate MOTPWM, MOTCUR or REVERSED errors. Diag\Test\Flas This checks the CRC checksum in each of the 8 pages of the Flash device used to store code then exits the test. No keys are used. This test is also run at power up. This can generate the FLASH fatal error. Diag\Test\Ram This checks the RAM device then exits the test. No keys are used. This test is also run at power up. This can generate the RAM fatal error. Diag\Test\Volt This checks that the 5v and 24v supplies are within tolerance. No keys are used. This test is also run at power up. This can generate the VLO or VHI errors. Diag\Ee These submenus are used to clear or check the EEPROM non volatile memory contents. Diag\Ee\Clr This clears the EEPROM and sets all the variables back to their factory defaults. Diag\Ee\Chk This checks that all the variables in the EEPROM are within their allowed range. If not, an ERRCHECK or MENUCHECK error is generated and the EEPROM is set with factory defaults. Diag\Rst This resets the unit the same as if it was power cycled. Menu Notes Any changed values are automatically saved into EEPROM when the SELECT key is pressed. PALS96 - User Manual Notes Page 21 of 26