A.2 SMART-AG Specifications INPUT/OUTPUT CONNECTORS SMART-AG COM/PWR +8 to +36 V DC at 2.5 W (typical while logging) a For the cable pinouts and drawings, see Section A.2.1, SMART-AG Power/Communications Development Kit Cable (01018256) starting on Page 61 Serial Com Ports RS-232 F Compliant (Rx and Tx signals only) CAN SAE J1939/ ISO 11783/ ISO 11898 Compliant Emulated Radar Output High= Supply Voltage -0.5V Minimum Low= 0.5V Maximum Load= 3K Ohm Minimum PPS Output 3.3 V CMOS Logic Compatible MKI Input 3.3V CMOS Logic/ 5V Tolerant INPUT/ OUTPUT CONNECTOR PROTECTION Electrical Conducted/ Coupled disturbance tolerance ISO 7637:2002 (Survives all pulse types) LED INDICATORS More details can also be found in Section 2.2.2, Status Indicators starting on Page 25 PHYSICAL Size 155.3 x 66.8 x 155 mm b Weight 495 g maximum ENVIRONMENTAL Operating Temperature -40C to +75C Storage Temperature -55C to +90C Humidity Not to exceed 95% non-condensing Immersion MIL-STD-810F Method 512.4 Procedure 1 Vibration c Random Sinusoidal Shock MIL-STD-810F Method 514.5 C17 IEC 68-2-6 ASAE EP455, 5.15.2 Level 1 MIL-STD-810 F Method 516.5 a. When tracking GPS satellites. b. denotes diameter, here and in the Dimensions graphic on Page 60. c. See also the Notice section of this manual starting on Page 13. SMART-AG User Manual Rev 5 59