Download USER MANUAL - Security Dynamics
Transcript
TM X-SERIES USER MANUAL DVR RV-DOME RV-DOME UN-TERMINATED UN-TERMINATED PSU PSU RV-DOME TERMINATED RS 485 DAISY CHAIN PSU & ALARM MODULE TERMINATED (B) ) If the Camera and Alarm Module is NOT the last in line, the Camera should be terminated and the Alarm Module unTerminated. The Alarm Module takes over the termination from the Camera i.e. it (the Alarm Module) should be unterminated! RV-DOME UN-TERMINATED DVR RV-DOME TERMINATED RV-DOME UN-TERMINATED RV-DOME TERMINATED RS 485 END OF LINE DAISY CHAIN PSU & PSU 5 ALARM MODULE UN-TERMINATED PSU PSU WIRELESS ALARM CARD (WIRELESS PIR DETECTOR) WARRANTY & SAFETY NOTICE: DISCONNECT ALL POWER BEFORE OPENING OR WORKING ON THE POWER SUPPLY UNIT AND ALARM CARD. WIRELESS ALARM CARDS SHOULD NOT BE HOT SWAPPED OR INSTALLED WHILST THE POWER IS LIVE. INSTALLATION MUST BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON. 5.1 FACTORY FITTED WIRELESS CARD (RV-PSU-ALM16-W) The Redvision Wireless Card is compatible with the Redvision Wireless PIR, Luminite Genesis Range and the Redwall Wireless Transmitter Module Part Code WF434T, (wireless enables Redwall PIRs). This PSU is compatible with the following RVX SERIES PTZs: RVX18, RVX18-IR, RVX18-W, RVX18-IR-W, RVX28, RVX28-IR, RVX28-W, RVX28-IR-W. Refer to 4.2 for RVX-PSU INTERNAL CONNECTIONS & 4.3 for ALARM MODULE DIP SETTINGS. 5.1.1 CONFIGURING WIRELESS ALARM MODULE ALARM INPUTS The RVX-PSU-ALM16-W has 16 Alarm Inputs. These can either be used as either HARDWIRED or WIRELESS Alarm Inputs, or a combination of both, e.g. 8 HARDWIRED & 8 WIRELESS. 12