Download JNEye User Guide
Transcript
2-132 UG-1146 2015.05.04 JNEye Channel Designer • • • • • Ideal transmission line Via model based on composite transmission line blocks Shunt and series capacitance Series inductance S-parameter model A channel design can include one or multiple channel components. JNEye Channel Designer can combine and generate Touchstone S-parameter models that can be used in link simulations. JNEye Channel Designer provides user friendly and integrated interfaces. The channel components and resulting channel models can be observed and analyzed using embedded plot functions or the JNEye Channel Viewer. In the 15.0 JNEye release, a 2-port single-ended channel model will be generated internally for all of the above components except the S-parameter model. After the single-ended model is generated, JNEye Channel Designer converts it into a 4-port differentialpair format by assuming that these two single-ended channels are uncoupled. Channel cascading of all channel components, which include S-parameter channel components, are done in the 4-port level. Starting the JNEye Channel Designer You can start JNEye Channel Designer in two ways: • Double-click JNEye_Channel_Designer.exe • Click Channel Designer in the JNEye Control Module The JNEye Channel Designer’s graphical user interface is shown in the following figure. Altera Corporation Functional Description Send Feedback