Download M22 / M23 / M23G AT Command User Guide
Transcript
<Value 0>, <Value 1>, …<Value 30>: 0 - 65535 The FIR coefficient value. Informative examples -Initial the HyperTerminal -Initial the MS -AT Command AT$AUPATH=3,1 $AUPATH: 1 OK /* Set FIR coefficient */ AT$AUFIR=65514, 65424, 65381, 65389, 65399, 194, 713, 593, 444, 1416, 1206, 65526, 1481, 4031, 63490, 16384, 63490, 4031, 1481, 65526, 1206, 1416, 444, 593, 713, 194, 65399, 65389, 65381, 65424, 65514 OK 2.6.9 Audio Uplink FIR $UPFIR Table: $UPFIR parameter command syntax Command $UPFIR =<value 0>, <value 1>, <value 30> $UPFIR=? Possible response(s) …., OK $UPFIR: (list of supported < value >) OK $UPFIR? $UPFIR: <value 0>, <value 1>, <value 30> …., OK Description This command is used to configure the FIR filter coefficient which the uplink (audio microphone) signal is be filtered. Note that this command has to be used after audio path is configured by AT$AUPATH. ©2006 BenQ Corporation. AT Command User Manual Confidential Property 252 Version: 1.7.7 20/09/2006