14.5
Off Node Process
Depending on the application, some units may not be used for LAN construction. The following
is an example of how to process a unit which is not used (off node process).
If Unit D is not used in the following LAN configuration, the power of Unit D is usually shut off, but
the electric current path from the LAN bus to the off node unit still exists.
When BUS (+) becomes dominant status (BUS (+)=5V), electric current flows from the bus driver
of the unit, which made BUS (+) dominant status, to the internal protective diode of MSM6636.
This is one such electric current path. Another path is the path from pull-up resistance of BUS
(–) to BI– terminal input pull-up resistance on-board MSM6636 of the off node. Figure 14-17 shows
these electric current paths.
To prevent this electric current from flowing, be certain to shut the unit power OFF, and to
disconnect the unit from the LAN bus.
14-12