Transmission start Message transmission command Local node Message=11 bytes Another node Message+response=12 bytes Re-transmission Re-transmission Local node Message=11 bytes Message=11 bytes Figure 6-18 Maximum NOACK Interrupt Generation 6.11 Response Transmission Standby Error Interrupt (NRSP) This flag is set when an IFR type 3 message was received, but the response data length (address 14H) has not been written. If the response data length is written before the “EOD” bit of the received message, the response transmission error flag is not set. Once the response data length is written, the IFR type 3 response transmission standby status is held until the IFR type 3 message is received and an IFR type 3 response is sent. Even if a message, other than an IFR type 3, is received or transmitted after the response data length is written, it is not necessary to write the response data length again. The written response data length is reset by an RES terminal input. Interrupt generation timing is shown below. LAN bus Message EOD 42.5msec INT Figure 6-19 NRSP Interrupt Generation Timing 6-15