6.1.3 Entry Delay 1 (Full Arm) Zones Sections [001] to [032]: Zones 1 to 32, First Digits = 03 Upon regular arming, the zone is Entry Delay 1 (see Entry Delay 1 Zones on page 15). Upon Stay/Sleep arming, the zone is bypassed by the system. See Zone Definition Status on page 19 for any exceptions. 6.1.4 Entry Delay 2 (Full Arm) Zones Sections [001] to [032]: Zones 1 to 32, First Digits = 04 Upon regular arming, the zone is Entry Delay 2 (see Entry Delay 2 Zones on page 15). Upon Stay/Sleep arming, the zone is bypassed by the system. See Zone Definition Status on page 19 for any exceptions. 6.1.5 Follow Zones Sections [001] to [032]: Zones 1 to 32, First Digits = 05 When a Regular, Stay, or Sleep armed Follow Zone opens, the control panel will immediately generate an alarm, unless an entry delay zone opens first: • • If a Regular/Stay/Sleep armed Follow Zone opens after an entry delay zone opens, the control panel waits until the entry delay timer has elapsed before generating an alarm. If a Regular/Stay/Sleep armed Follow Zone opens after more than one entry delay zone opens, the control panel will wait until the entry delay timer of the zone that opened first has elapsed. This feature is commonly used when a motion detector is protecting the area occupied by the entry point keypad. This will prevent the motion detector from causing an alarm when a user enters through the entry point to disarm the system. See Zone Definition Status on page 19 for any exceptions. 6.1.6 Follow (Sleep / Full Arm) Zones Sections [001] to [032]: Zones 1 to 32, First Digits = 06 Upon regular arming or sleep arming, the zone is Follow. Upon Stay arming, the zone is bypassed by the system. See Zone Definition Status on page 19 for any exceptions. 6.1.7 Follow (Full Arm) Zones Sections [001] to [032]: Zones 1 to 32, First Digits = 07 Upon regular arming, the zone is Follow (see Follow Zones on page 16). Upon Stay or Sleep arming, the zone is bypassed by the system. See Zone Definition Status on page 19 for any exceptions. 6.1.8 Instant Zones Sections [001] to [032]: Zones 1 to 32, First Digits = 08 When an armed Instant Zone opens, the control panel immediately generates an alarm. Instant Zones are commonly used for windows, patio doors, skylights and other perimeter type zones. See Zone Definition Status on page 19 for any exceptions. 6.1.9 Instant (Sleep / Full Arm) Zones Sections [001] to [032]: Zones 1 to 32, First Digits = 09 All zones defined as Instant/Stay zones become Instant zones when the system is Regular armed. All zones defined as Instant/Stay zones become bypassed when the system is Stay armed. See Zone Definition Status on page 19 for any exceptions. 6.1.10 Instant (Full Arm) Zones Sections [001] to [032]: Zones 1 to 32, First Digits = 10 All zones defined as Instant/Stay/Sleep zones become Instant zones when the system is Regular armed. All zones defined as Instant/Stay/Sleep zones become bypassed when the system is Stay or Sleep armed. See Zone Definition Status on page 19 for any exceptions. 16 Reference & Installation Manual