Download Esprit E55 : Reference & Installation Manual
Transcript
6.1.11 Instant Fire Zones Sections [001] to [032]: Zones 1 to 32, First Digits = 11 when a Instant Fire zone opens, whether it is armed or disarmed, the control panel will send the corresponding Alarm Report Code and the alarm is always audible regardless of other settings. Fire alarms generate an intermittent (pulsed) bell/siren output signal as shown in Figure 9. Figure 9: Bell/Siren Output during a Fire Alarm 6.1.12 Delayed Fire Zones Sections [001] to [032]: Zones 1 to 32, First Digits = 12 When a Delayed 24Hr. Fire zone opens, whether it is armed or disarmed, the control panel will react as shown in Figure 10. Delayed 24Hr. Fire zones are commonly used in residential homes where a smoke detector often generates false alarms (i.e., burning bread, etc.). Fire alarms generate an intermittent (pulsed) bell/siren output signal as shown in Figure 9. 6.1.13 Figure 10: Delayed 24Hr Fire Zone Instant Fire Silent Zones Sections [001] to [032]: Zones 1 to 32, First Digits = 13 When a Instant Fire Silent zone opens, whether it is armed or disarmed, the control panel will generate the following: The control panel can send the corresponding Alarm Report Code and the alarm will be silent regardless of other settings. 6.1.14 Delayed Fire Silent Zones Sections [001] to [032]: Zones 1 to 32, First Digits = 14 When a Delayed Fire zone opens, whether it is armed or disarmed, the control panel will react as shown in Figure 10. Delayed 24Hr. Fire zones are commonly used in residential homes where a smoke detector often generates false alarms (i.e., burning bread, etc.). The control panel can send the corresponding Alarm Report Code and the alarm will be silent regardless of other settings. 6.1.15 24 Hr. Buzzer Zones Sections [001] to [032]: Zones 1 to 32, First Digits = 15 When a 24Hr Buzzer Zone opens, whether the zone is armed or disarmed, the control panel sets off the keypad’s buzzers to indicate that the zone was breached. The control panel will report the alarm, but will not enable the bell/siren output. Enter any valid access code on the keypad to stop the buzzer. This zone definition is particularly useful when a user wishes to be notified when something such as a safe or locker within the home has been accessed (i.e. a child accessing a valuable collection). 6.1.16 24 Hr. Burglary Zones Sections [001] to [032]: Zones 1 to 32, First Digits = 16 when a 24Hr Burglary Zone opens, whether the system is armed or disarmed, the control panel will immediately generate an alarm. This alarm is defined by the alarm type, configured in Zone Programming under zone options [4] and [5]. See Alarm Types on page 20. Esprit E55 17