Operating Basics Table 2-5: Case 3: Fixed points (including M period signal) Ouput Frequency = Display Frequency = Internal clock / Data points M period Example: Fixed point 16 (two period signal) minimum A example " maximum Display Frequency 0.01 Hz 32 kHz 1.0 MHz Output Frequency 0.02 Hz 64 kHz 2.0 MHz Internal Clock 0.16 Hz 512 kHz 16 MHz 0.02 Hz = 2 0.16 Hz/16 64 kHz = 2 512 kHz/16 1.0 MHz = 2 16 MHz/16 1 cycle = 32 kHz Internal Clock ( 2 MHz) Point 1 16 Figure 2-29: Fixed point (one period signal) User Waveform when Output Frequncy = Display Frequency = 32 kHz. 2 cycle = 32 kHz 1 cycle = 64 kHz 1 16 Figure 2-30: Fixed point User Waveform when (two period signal) Display Frequency = 32 kHz, (one period signal) Output Frequncy = 64 kHz. AFG310 and AFG320 User Manual 2-47