Download User's Manual
Transcript
APPLIED OPERATIONS/Image Acquisition 1 Setting the Z-direction scanning range While acquiring image, move the Z stage according to the range of the multiple sections to be observed (Z-direction scanning range). From the panel page tabs shown on the bottom right of the [Acquire] panel, select the [Z Stage] sub-panel. <Go> button Moves to the set scanning stop position. Use this button to check the scanning stop position. [Stop Z] text box Shows the scan stop position in the range of the observed cross-section (Zdirection scanning range). <Set> button Sets the current stage position as the scanning stop position of the range of the observed cross-section (Z-direction scanning range). <Z stage coarse adjustment> buttons Displaces the Z stage on a large scale. <Z stage fine adjustment> buttons [Current Pos] text box Displaces the Z stage on a fine scale. Shows the current position of the stage. <Set Zero> button [Start Z] text box Sets the current stage position as the home position. Pressing this button also clears the [Stop Z] and [Start Z] values. Shows the scan start position in the range of the observed cross-section (Zdirection scanning range). <Set> button [Step Size] text box Sets the current stage position as the scanning start position of the range of the observed cross-section (Z-direction scanning range). Set the number of steps using the < > or < > button. This number can also be input directly from the keyboard. Recommended step size <Go> button Shows the number of steps calculated by the system so that the scale of depth in the Z-direction of the acquired image is identical to the scale of the plane in the X- and Y-directions. Moves to the set scan start position. Use this button to check the scan start position. [Slices] text box Shows the number of images acquired. This number can also be input directly from the keyboard. TIP [Locked] check box Fig. 2-18 [Z Stage] Sub-panel Enables the Z-Motor operation. The moving amount assigned to the <Z stage fine adjustment> and <Z stage coarse adjustment> buttons can be changed. See section 1-3 in MAINTENANCE, “Setting the System Configuration” for detailed operations. 1. Check the [Locked] check box in the [Z Stage] sub-panel. Do not turn the fine focus adjustment knob while the [Locked] check box is checked, for this may damage the Z motor. 2-56 Page
Related documents
Brother P-touch MW-145BT User`s guide
Olympus FV300 User's Manual
Olympus Fluoview FV1000 User's Manual
Imaging Station for Life Science
Emergency-Call System - Alpha Communications
Emergency-Call System - Alpha Communications
Brother P-touch 9800PCN User`s guide
Andor iQ USER GUIDE
Promotion sur les Produits de soudage & travail des métaux
A COVER.FM - ASP Cleaning Products
User`s Manual
General Accessories