Measurement 11 heat regenerated drier) the temperature compensation may lag behind, which may result in significant measurement errors. 5.4 Totalizer The totalizer keeps track of the total consumed amount of compressed air in normal cubic meters, or in scf depending on which unit you choose to read out. The refresh interval is 1 second, actual measurement data will be available on the display and by Modbus. For back up reasons, the totalizer value is written to it's internal memory with an interval of 15 minutes. A power down might result in maximum 15 minutes of totalizer data loss. In bi-directional operation, negative flow is subtracted from the totalizer. The totalizer will count backwards as the compressed air is delivered back to the supply side. The totalizer can only be reset to zero. It's not possible to set it to a different value. © 2015 Van Putten Instruments BV | MAN-VP-SPRO-UK | Revision:1502 | Date:11-06-2015