Download Installation Manual

Transcript
SMA Solar Technology AG
14 Technical Data
Features
DC connection
SUNCLIX DC connector
AC connection
spring clamp terminal
Display
Bluetooth
LC graphic display
as standard
RS485, galvanically isolated
optional
Speedwire
optional
Speedwire with Webconnect function
optional
Multi-function relay
optional
Power Control Module
optional
Electronic Solar Switch
Electrical endurance in the event of a short
circuit, at nominal current of 33 A
at least 50 switching processes
Maximum switching current
33.0 A
Maximum switching voltage
1,000 V
Maximum PV power
20 kW
Degree of protection when plugged in
IP65
Degree of protection when not plugged in
IP21
Torques
Upper enclosure lid screws
6.0 Nm
Lower enclosure lid screws
2.0 Nm
DC lid screws
3.5 Nm
Additional earth terminal
6.0 Nm
Cheese-head screws (M5x10) for securing the
enclosure to the rear panel
3.5 Nm
SUNCLIX swivel nut
2.0 Nm
RS485 communication connection
1.5 Nm
Terminal for multi-function relay
0.5 Nm
Installation Manual
STP8-17TL-IA-en-31
105