Transcript
SMA Solar Technology AG 14 Technical Data Protective Devices DC reverse polarity protection Protection against module reverse currents Input-side disconnection device DC overvoltage protection Short-circuit diode, electronic string fuse Electronic string fuse Electronic Solar Switch, SUNCLIX DC connector Thermally monitored varistors optional: surge arrester type II AC short-circuit current capability Grid monitoring Maximum permissible fuse protection Earth fault monitoring Current control SMA Grid Guard 4 50.0 A Insulation monitoring Riso > 687.5 k Ω All-pole sensitive residual-current monitoring unit available String-failure detection available General Data Width x height x depth with Electronic Solar Switch Weight Length x width x height of packaging 665 mm x 690 mm x 265 mm 59 kg 780 mm x 380 mm x 790 mm Transport weight 65 kg Climatic class as per IEC 60721-2-1 4K4H Operating temperature range Maximum permissible value for relative humidity, non-condensing Maximum operating altitude above MSL Power loss in night operation Topology − 25°C … +60°C 100% 3,000 m <1W transformerless Cooling concept OptiCool: temperature-controlled fan Fan connection designed for safe disconnection according to DIN EN 50178:1998-04 Degree of protection according to IEC 60529 Protection class (according to IEC 62103) Installation Manual IP65 I STP8-17TL-IA-en-31 97