5–4
PARAMETERS
Password
Parameter #
P.00
Description
Range
Password
{0, 9999}
When the DTR-65 is locked the display will show "====" for
this parameter until the [+] or [-] button is pressed. Enter in the
password to unlock the parameters.
When the DTR-65 is not locked, the display will show "0000" for
this parameter. Enter in a new password to lock the parameters.
When the DTR-65 is locked, all parameters will be viewable but
cannot be changed and no calibrations will be performed.
Miscellaneous
Parameter #
P.19
Description
Default
Tension number format
0
Tells whether tension display is 3-digit with no fixed right-hand
zero or 3-digit with fixed right-hand zero.
0=
Auto Select between formats. (Based on value in
Maximum Tension C1.3 or C2.5).
P.20
1=
3-digit with no fixed right-hand zero.
2=
3-digit with fixed right-hand zero.
Tension polarity
+1
Set to -1 to show positive tension when the force is acting in
the direction opposite the force direction arrow on the load
cells. Set automatically by Precision calibration.
P.21
DP position
0
Set the decimal point position to show when displaying tension
0=
0000
1=
0000.
2=
000.0
3=
00.00
4=
0.000
P.22
Firmware Version. Displays the firmware version.
P.23
Exit from menu and return to displaying tension
www.maxcessintl.com
MAGPOWR DTR-65
MI 850A349 1