4-44
MENU DESCRIPTIONS
Re-seek on ASC – Checking this option will cause the MCP-05 sensor
positioner to re-seek to obtain the web location each time the ASC
(Automatic Sensor Control) signal triggers. This can be useful in centerguiding applications to accommodate web width changes.
Seek timeout – An optional time value (in seconds) to cancel seek operations.
If the seek operation does not find the web within the specified time, the
systems enters the Servo Center state and the sensor(s) retract. Specify a
value of zero to disable seek timeouts.
Control Sources – Control for the external MCP-05 device requires two alarm
signals. The Control Sources setting allows the A and B alarm signals of the
MCP-05 to be mapped to any of the 4 available alarm outputs. The
configured output must be correctly connected to the MCP-05 input. When
the ‘Propagate Alarms’ option is enabled, the alarms selected here are
forwarded to the MCP-05 alarm outputs.
MCP-05 drive type – Specify the MCP-05 type. There are three MCP-05
configurations as shown here.
1 drive + 1 sensor
1 drive + 2 sensors
2 drives + 2 sensors