4-37 MENU DESCRIPTIONS HARDLOCK Hard lock modifies actuator reaction while in manual mode. Normal manual posture removes all motor drive signals. In some applications, forces due to gravity or web tension can cause unwanted actuator movement when the motor is not driven. The hard lock option changes manual operation so actuator position is actively maintained to prevent movement from outside forces while in manual mode. Hard lock, if enabled is applied in all cases where manual posture is active such as when external lock from the digital inputs is active. Navigation: MANUAL SETUP Page forward HARDLOCK Enable Hardlock – Check this box to turn the hardlock feature on. Hardlock Polarity – Sets the hardlock correction polarity. Hardlock Gain – Sets the hardlock control loop gain. This can be changed with the slider control or with the arrow buttons for finer control. Press ACCEPT to save changes made to this screen. Press CANCEL to exit without saving any changes. www.maxcessintl.com FIFE-500 MI 2-262 1 C