Download Operating Instructions - CROUSE
Transcript
6. Type configuration Std. Catalog No. NSSFMVSY150/**** Lamp T Class (Gas) Watt (W) Type Shape 150 HPS T/E NSSFMVMY150/**** 150 MH T/E NSSFMVSY250/**** 250 HPS T/E NSSFMVMY250/**** 250 MH T/E NSSFMVSY400/**** 400 HPS T/E NSSFMVMY400/**** 400 MH T/E NSSFMVMY400H/**** 400 MH T/E 7. Installation 7.1 General The respective national regulations IEC/EN 60079-14 as well as the general rules of engineering which apply to the installation and operation of explosion protected apparatus will have to be observed! IM0086. Revision 2 08/12 Voltage 220V 230V 240V 220V 230V 240V 50Hz 50Hz 50Hz 60Hz 60Hz 60Hz T (Dust) +40ºC +50ºC +55ºC +40ºC +50ºC +55ºC Weight (Kg) T4 T3 T3 125 135 140 12 T4 T3 T3 125 135 140 12 T3 T3 T3 160 170 175 13 T3 T3 T3 160 170 175 13 T3 T2 / 195 205 / 15 T3 T2 / 195 205 / 15 T3 T2 / 195 205 / 15 Note: HPS=high pressure sodium vapour lamp MH=high pressure metal halide T=Tube shape E=Bulb shape The improper installation and operation may If the cable glands included in the scope of delivery are replaced with other cable glands, the result in the explosion protection and “nR” properties must be checked before putting invalidation of the guarantee. into operation. 7.2 Mounting the floodlight Restricted breathing test may be carried out 7.2.1 Mounting the bracket as per section 11. Only use the accompanying mounting bracket! Use M12 bolts, plain washer and spring washer 7.4 Opening/closing the floodlight 7.4.1 General to securely fasten the Trunnion bracket to a suitable base with sufficient load-bearing The opening of floodlight always shall be capacity. See Fig.1 and Fig.2 for detail. without voltage! All gasket seals must be clean and 7.2.2 Pole mounting undamaged before closing the floodlight. The pole adapter is not included in the lamp's Make sure the floodlight is well closed before scope of delivery and is available as an accessory. Screw the floodlight mounting bracket operation! Unscrew all screws in the glass frame and lift to the pole adapter as shown in Fig.1. The pole adapter can be mounted onto a 2” pipe. the protective glass to one side. Secure the pole adapter using the four clamping Unscrew the terminal compartment cover and remove the terminal compartment cover. screws (62Nm,see Fig.2). Carry out the steps in reverse order to close the The connection cable may not be damaged in floodlight and Check all screws to ensure a the process. An explosion protected cable gland(not included in the scope of delivery)can secure fit (Torque for screws: 2.5 Nm). be screwed into the pole adapter, enabling the 7.5 Electrical connection pole to be used for cable routing (see Fig.2). The electrical connection of the lamp must The connection cable must not be damaged only be established by qualified electricians. in the process. Make sure the supply voltage is the same as 7.2.3 Wall bracket mounting the luminaire voltage! The wall bracket is not included in the lamp's Use proper supply wiring as specified on the scope of delivery and is available as an nameplate of the luminaire and in this accessory. instructions! Use appropriate screws, spring washers and Excessive tightening may affect or damage grommets to secure the wall bracket to a suitable wall at the four drilled holes (see Fig.3). the connection. Only heat resistant cable according to the data Slide the floodlight with the pole adapter onto the pipe of the wall bracket and secure with the on the type label may be used for the electrical installation! four clamping screws (max.62Nm). Connect cable according to the terminal 7.2.4 Vertical adjustment of floodlight numbering and circuit diagram. Loosen the two pivot bolts on the floodlight yoke The conductors shall be connected with special to position floodlight at the desired tilt angle care in order to maintain the explosion category. (within the acceptable aiming range limits). See Leads connected to the terminals shall be Fig.4. Re-tighten the adjustment screws(26Nm). insulated for the appropriate voltage and this The lamp must not be illuminated when at a insulation shall extend to within 1mm of the metal distance of less than 0.5m from inflammable of the terminal throat. The conductor itself shall not be damaged. The connectible min. and max. material. conductor cross-sections shall be observed (see 7.3 Cable entries/blanking plugs technical data). All terminal screws, used and unused, shall be tightened down (Torque for The “restricted breathing(Ex nR)" properties terminal screws: 1.2~2 Nm for MK/6). must be preserved when, for example, using cables and wires of sufficient diameter(see also Main connection: See wiring diagram. IEC/EN 60079-14). Unused holes shall be 7.6 Lamp mounting closed with certified blanking plug in order to Only must be mounting appropriated lamps establish the protection category. The cable for the supplied floodlight see indications on glands and blanking plugs must be used in compliance with IEC 60079-31. The authoritative the nameplate of the floodlight and in this instructions! mounting guideline for the cable glands used must be observed. Mounting the selected cable See section 7.4 for notes on opening and closing entries(cable glands) acc. type and dimensions the lamp. The lamp must be screwed tightly into of the main connection cable and following their the lampholder. manufacturer instructions. The cable glands and Ensure it is screwed in fully so that no sparks or blanking plugs should be at least Ex nR certified, other unauthorized operating states may occur. Protect the glass on the lamp from breaking and should be also Ex tb certified if the whole when screwing in. product is Ex tb certified also. Cooper Electronic Technologies (Shanghai) Co., Ltd. Page 2 of 3