Download Xantrex MS2000 User's Manual
Transcript
Configuration Charger Configurable setting This setting lets you enable or disable the operation of the main charger. When the main charger is enabled and AC is connected to the input, the house battery bank will charge. The Echo Charger will charge if it is enabled separately in the Echo Charger menu. See “Echo Chg” on page 3–18. Important: Both the main charger and the Echo Charger must be set to enabled for the Echo Charger to operate. The Disabled setting of this item will disable the main charger and can be disabled at any time during the charge cycle. If the charger is enabled and the AC is not qualified as good, then the charger will not operate until AC qualifies as good. The charger can be enabled or disabled from the front panel of the MS2000 or from the System Control Panel (SCP). In the example shown, the charger is enabled. Charger [Enabled] Value Default Enabled Enabled Disabled Outcome Use the default Enabled setting to ensure batteries are always being charged when connected to an AC source. Disabling the charger will turn off the charge function. Then the next time qualified AC power is connected, the charger is automatically enabled and charging will begin, if Force Charge is enabled. If Force Charge is not enabled, charging will not occur until the Charger setting is changed from disabled to enabled. See “Force Charge” on page 3–24 for more information on this feature. 975-0125-02-01 3–11