Troubleshooting Table 4-3 provides a detailed description of the warning messages and solutions. Table 4-3 Warning Messages Warning Number Message Warning Type W0 FET1 over-temp. Check airflow around it. W1 Cause Solution Automatic FET1 Over Temperature Warning Ensure adequate ventilation around the MS2000. Reduce the AC loads. FET2 over-temp. Check airflow around it. Automatic FET2 Over Temperature Warning Ensure adequate ventilation around the MS2000. Reduce the AC loads. W2 Bulk cap. over-temp. Check airflow around it. Automatic DC Bulk Capacitor Over Temperature Warning Ensure adequate ventilation around the MS2000. Reduce the AC loads. W3 Transf’r over-temp. Check airflow around it. Automatic Transformer Over Temperature Warning Ensure adequate ventilation around the MS2000. Reduce the AC loads. W4 Battery over-temp. Check battery settings. Automatic Battery Over Temperature Warning Check battery voltage and battery cable connections. Stop charging, if necessary. Check for excessive ambient temperature and adequate ventilation in the battery compartment W5 Over-temperature. Check airflow around it. Automatic Ambient Over Temperature Warning Ensure adequate ventilation around the MS2000. Reduce charge rate or AC load. W6 Too many AC loads. Turn some off. Automatic AC Overload Warning (AC OUPUT) Turn off some AC loads. W7 You have enabled system restart after faults. Automatic Auto Restart After Fault Feature Enabled. (This parameter is not accessible through the System Control Panel. In the future, this feature may be configurable with advanced panels.) If in invert mode, the unit may start up unexpectedly. W8 You have enabled battery equalization. See manual. Automatic Equalization Enabled Warning Make sure voltage sensitive loads are disconnected from batteries. 975-0125-02-01 4–7