Download Omron C200HS User's Manual
Transcript
Section 10-6 Host Link Errors 10-6 Host Link Errors These error codes are received as the response code (end code) when a command received by the C200HS from a host computer cannot be processed. The error code format is as shown below. @ X X Node no. X X Header code X X End code X X FCS : ↵ Terminator The header code will vary according to the command and can contain a subcode (for composite commands). End code Contents Probable cause Corrective measures 00 Normal completion --- 01 Not executable in RUN mode The command that was sent cannot be executed when the PC is in RUN mode. 02 Not executable in MONITOR mode The command that was sent cannot be executed when the PC is in MONITOR mode. 0B Not executable in PROGRAM mode The command that was sent cannot be executed when the PC is in PROGRAM mode. This code is not presently being used. 13 FCS error The FCS is wrong. Either the FCS calculation is mistaken or there is adverse influence from noise. Check the FCS calculation method. If there was influence from noise, transfer the command again. 14 Format error The command format is wrong. Check the format and transfer the command again. 15 Entry number data error The areas for reading and writing are wrong. Correct the areas and transfer the command again. 16 Command not supported The specified command does not exist. Check the command code. 18 Frame length error The maximum frame length was exceeded. Divide the command into multiple frames. 19 Not executable Items to read not registered for composite command (QQ). Execute QQ to register items to read before attempting batch read. 23 User memory write-protected A3 Aborted due to FCS error in transmit data A4 Aborted due to format error in transmit data Pin 1 on C200HS DIP switch is ON. Turn OFF pin 1 to execute. The error was generated while a Check the command data and try command extending the transfer again. g over more g th one frame f b i executhan was being ted. A5 Aborted due to entry number data error in transmit data A8 Aborted due to frame length error in transmit data Other --- Power Interruptions --Check the relation between the command and the PC mode. Note: thatt point has N t The Th data d t up tto th i th already been written to the appropriate area of the CPU CPU. Influence from noise was received. Transfer the command again. The following responses may be received from the C200HS if a power interruption occurs, including momentary interruptions. If any of these responses are received during or after a power interruption, repeat the command. Undefined Command Response @00IC4A*↵ No Response If no response is received, abort the last command and resend. 399
Related documents
Emerson Universal-R Technical data
C200HX/HG/HE Manuel d`utilisation - Support
SYSMAC PROGRAMMABLE CONTROLLERS C200H (CPU01
Selectron LD-007 Programming instructions
sysmac cqm1 automate programmable manuel de
IDSC-C1DR/C1DT-AE ID Controller User's Manual
sysmac c200hx/c200hg/c200he automates programmables
Avaya Activity Reporter Client Version User's Manual
From C200H to CS1
Replacement Guide From CJ1M/CJ1G to CJ2M
ESET Mail Security for Microsoft Exchange Server
Using BIOS