Download Goodman Mfg R-410A User's Manual
Transcript
TECHNICAL MANU AL MANUAL GPC 14 SEER R-410A Package Air Conditioners with R-410A • Refer to Service Manual RS6300011 (Horizontal) for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information. • Models listed on page 3. • Models qualify for the 2009 and 2010 Federal Tax Credits for Energy Efficiency** **Note that these tax credits are subject to specific requirements set forth in the American Recovery and Reinvestment Act of 2009 and in the Internal Revenue Code. Goodman recommends that consumers consult a tax professional if they have questions about the applicability of these credits. This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person. Copyright © 2009 Goodman Manufacturing Company, L.P. RT6322007r2 August 2009 PRODUCT IDENTIFICATION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. G P C 14 24 H 4 1 A VOLTAGE: 1: 208-230v 1ph/60Hz BRAND: G: Goodman® A MINOR REVISION: A: Initial Release PRODUCT FAMILY: C: Cooling Brand REFRIGERANT: 4: R-410A PRODUCT TYPE: Package Unit PRODUCT SERIES: SEER Rating CONFIGURATION: H: Horizontal MAJOR REVISION: A: Initial Release NOMINAL CAPACITY 24: 24,000 BTUH 30: 30,000 BTUH 36: 36,000 BTUH 42: 42,000 BTUH 48: 48,000 BTUH 60: 60,000 BTUH WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. Goodman will not be responsible for any injury or property damage arising from improper service or service procedures. If you install or perform service on this unit, you assume responsibility for any personal injury or property damage which may result. Many jurisdictions require a license to install or service heating and air conditioning equipment. WARNING 2 Installation and repair of this unit should be performed ONLY by individuals meeting the requirements of an "entry level technician" as specified by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI). Attempting to install or repair this unit without such background may result in product damage, personal injury or death. WARNING PRODUCT IDENTIFICATION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. GPC1424H41A* GPC1430H41A* GPC1436H41A* GPC1442H41A* GPC1448H41A* GPC1460H41A* Models qualify for the 2009 and 2010 Federal Tax Credits for Energy Efficiency** **Note that these tax credits are subject to specific requirements set forth in the American Recovery and Reinvestment Act of 2009 and in the Internal Revenue Code. Goodman recommends that consumers consult a tax professional if they have questions about the applicability of these credits. WARNING The United States Environmental Protection Agency (“EPA”) has issued various regulations regarding the introduction and disposal of refrigerants introduced into this unit. Failure to follow these regulations may harm the environment and can lead to the imposition of substantial fines. These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office. Do not connect or use any device that is not design certified by Goodman for use with this unit. Serious property damage, personal injury, reduced unit performance and/or hazardous conditions may result from the use of such non-approved devices. WARNING To prevent the risk of property damage, personal injury, or death, do not store combustible materials or use gasoline or other flammable liquids or vapors in the vicinity of this appliance. WARNING 3 PRODUCT DESIGN GPC Package Cooling Units are designed for outdoor installations only in either residential or light commercial applications. - Due to their design Scroll Compressors are inherently more tolerant of liquid refrigerant. NOTE: Even though the compressor section of a Scroll compressor is more tolerant of liquid refrigerant, continued floodback or flooded start conditions may wash oil from the bearing surfaces causing premature bearing failure. - Scroll Compressors use white oil which is compatible with 3GS oil which may be used if additional oil is required. - Operating pressures and amp draws may differ from standard reciprocating compressors. This information may be found in the "Cooling Performance Data" section. The connecting ductwork (Supply and Return) can be connected for either horizontal or vertical airflow. In the vertical application a matching Roof Curb is recommended. A return air filter must be installed behind the return air grille(s) or provision must be made for a filter in an accessible location within the return air duct. The minimum filter area should not be less than those sizes listed in the Specification Section. Under no circumstances should the unit be operated without return air filters. A 3/4” PVC pipe is provided for removal of condensate water from the indoor coil In order to provide proper condensate flow, a drain trap is supplied and shipped loose inside the unit for field installation. (Do not reduce the drain line size.) Refrigerant flow control is achieved by use of restrictor orifices. GPC units use the FasTest Access Fitting System with a saddle that is either soldered to the suction and liquid lines or is fastened with a locking nut to the access fitting box (core) and then screwed into the saddle. Do not remove the core from the saddle until the refrigerant charge has been removed. Failure to do so could result in property damage or personal injury. Location and Clearances NOTE: To ensure proper condensate drainage, unit must be installed in a level position. 10" 36" The single phase units use permanent split capacitor (PSC) design compressors. Starting components are therefore not required for these units. A low microfarad run capacitor assists the compressor to start and remains in the circuit during operation. WALL UNIT All GPC14 units have X-13 indoor blower motors that are energized by a 24V signal from the thermostat and are constant torque motors with very low power consumption. The X13 features an integral control module. Air for condensing (cooling cycle) is drawn through the outdoor coil by a propeller fan, and is discharged vertically out the top of the unit. The outdoor coil is designed for .0 static. No additional restriction (ductwork) shall be applied. Conditioned air is drawn through the filter(s), field installed, across the coil and back into the conditioned space by the indoor blower. GPC1424-30H41* use Copeland Reciprocating Compressors. GPC1436-60H41* use Copeland Scroll Compressors. There are a number of design characteristics which are different from the traditional reciprocating compressor. 4 36" 36" Outside Slab Installation - Horizontal (H) Minimum clearances are required to avoid air recirculation and keep the unit operating at peak efficiency. PRODUCT DESIGN In installations where the unit is installed above ground level and not serviceable from the ground (Example: Roof Top installations), the installer must provide service platform for service person with rails or guards in accordance with local codes or ordinances or in their absence with the latest edition of the Uniform Mechanical Code Section 305. 36" UN I T NOTE: Unit can also use roof curb. PL EN UM 24" PL AT F OR RB CU M 36" Rooftop Installation - Horizontal (H) WARNING TO PREVENT POSSIBLE PROPERTY DAMAGE, THE UNIT SHOULD REMAIN IN AN UPRIGHT POSITION DURING ALL RIGGING AND MOVING OPERATIONS. TO FACILITATE LIFTING AND MOVING IF A CRANE IS USED, PLACE THE UNIT IN AN ADEQUATE CABLE SLING. Refer to Roof Curb Installation Instructions for proper curb installation. Curbing must be installed in compliance with the National Roofing Contractors Association Manual. 5 PRODUCT DESIGN GPC14[24-60]H41A* HKR ELECTRICAL DATA Circuit #1 Model and Heat Kit Usage GPH1424H41A* HKR05*,C* HKR08*,C* HKR10*,C* GPH1430H41A* HKR05*,C* HKR08*,C* HKR10*,C* HKR15*,C* GPH1436H41A* HKR05*,C* HKR08*,C* HKR10*,C* HKR15*,C* GPH1442H41A* HKR05*,C* HKR08*,C* HKR10*,C* HKR15*,C* HKR20*,C* GPH1448H41A* HKR05*,C* HKR08*,C* HKR10*,C* HKR15*,C* HKR20*,C* GPH1460H41A* HKR05*,C* HKR08*,C* HKR10*,C* HKR15*,C* HKR20*,C* Circuit #2 Minimum Circuit Ampacity at 208 / 240V Maximum Overcurrent Protection (amps) at 208 / 240V Minimum Circuit Ampacity at 208 / 240V Maximum Overcurrent Protection (amps) at 208 / 240V Actual kW & BTU at 240V 24 / 27 33 / 28 45 / 51 30 / 30 40 / 40 60 / 60 ---------- ---------- 4.75 / 16,200 7.00 / 23,800 9.50 / 32,400 24 / 27 30 / 30 ---- ---- 4.75 / 16,200 34 / 39 45 / 52 45 / 52 40 / 40 60 / 60 60 / 60 ------22 / 25 ------30 / 30 7.00 / 23,800 9.50 / 32,400 14.25 / 48,600 24 / 34 / 45 / 45 / 27 39 52 52 30 / 30 40 / 40 60 / 60 60 / 60 ---------22 / 25 ---------30 / 30 4.75 / 16,200 7.00 / 23,800 9.50 / 32,400 14.25 / 48,600 25 / 27 34 / 39 30 / 30 40 / 40 ------- ------- 4.75 / 16,200 7.00 / 23,800 46 / 52 46 / 52 46 / 52 60 / 60 60 / 60 60 / 60 ---22 / 25 43 / 49 ---30 / 30 60 / 60 9.50 / 32,400 14.25 / 48,600 19.50 / 66,500 25 / 34 / 46 / 46 / 46 / 28 40 53 52 52 30 / 30 40 / 40 60 / 60 60 / 60 60 / 60 ---------22 / 25 43 / 49 ---------30 / 30 60 / 60 4.75 / 16,200 7.00 / 23,800 9.50 / 32,400 14.25 / 48,600 19.50 / 66,500 26 / 30 36 / 40 48 / 54 30 / 30 40 / 40 60 / 60 ---------- ---------- 4.75 / 16,200 7.00 / 23,800 9.50 / 32,400 48 / 54 48 / 54 60 / 60 60 / 60 22 / 25 43 / 49 30 / 30 60 / 60 14.25 / 48,600 19.50 / 66,500 IMPORTANT NOTE: A separate power supply is required for the HKR heater kit. WARNING 6 All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent protection during refrigeration cycle. PRODUCT DIMENSIONS GPC14[24-60]H41A* A 14.000 4.512 4.500 14.000 SUPPLY 6.500 14.000 RETURN BACK VIEW (DUCT OPENINGS) 66.542 B 34.075 Chassis Small Model A B GPC1424 33 30½ GPC1430 33 30½ GPC1436 33 35½ GPC1442 33 35½ GPC1448 33 38½ GPC1460 33 38½ Medium Large Dimensions in inches 7 PACKAGE COOLING SPECIFICATIONS COOLING COOLING CAPACITY, BTUH CAPACITY SEER / EER UNIT VOLTAGE (NAMEPLATE) ELECTRICAL SPECIFICATION GPC14[24-36]H41A* GPC1424H41* GPC1430H41* GPC1436H41* 24,600 28,400 35,600 14.5 / 12.1 14.0 / 12.0 14.0 / 12.0 208-230/1/60 208-230/1/60 208-230/1/60 AMPS (TOTAL) 10.5 13.16 20.06 MINIMUM CIRCUIT AMPACITY 12.5 15.6 24.2 20 25 40 MAXIMUM OVERCURRENT PROTECTION (1) RECIP RECIP SCROLL RATED LOAD AMPS 7.9 9.8 16.7 LOCKED ROTOR AMPS 41 55 79 CONDENSER HORSEPOWER 1/6 1/4 1/4 FAN MOTOR RPM 815 830 830 FULL LOAD AMPS 1.1 1.5 1.5 COMPRESSOR TYPE LOCKED ROTOR AMPS CONDENSER FAN BLADE DIAMETER (INCHES) / NUMBER OF BLADES CONDENSER FACE AREA - SQ. FT. COIL NUMBER OF ROWS FINS PER INCH 1.7 3.0 3.0 22 / 3 22 / 3 22 / 3 13.4 13.4 13.4 1 1 1 24 24 24 1/2 - 5 1/2 - 5 1/2 - 5 FULL LOAD AMPS 1.5 1.86 1.86 LOCKED ROTOR AMPS NA NA NA EVAPORATOR HORSEPOWER - NO. OF SPEEDS BLOWER MOTOR MOTOR SPEED TAP - COOLING RPM T2 T2 T2 1050 1050 1050 EVAPORATOR DIAMETER X W IDTH (INCHES) 10 X 8 10 X 8 10 X 8 BLOWER HI EFFICIENCY COOLING CFM 850 1,050 1,200 5 TON NOMINAL COOLING CFM NA NA NA FAN ONLY COOLING CFM 800 950 1,100 MAX EXTERNAL STATIC PRESS ("w.c.) 0.5 0.5 0.5 EVAPORATOR FACE AREA - SQ. FT. 5.25 4.67 5.2 COIL NUMBER OF ROWS 3 4 3 FINS PER INCH 16 16 14 GENERAL FILTER SIZE - SQ. FT. * 20 x 20 x 1 20 x 25 x 1 25 x 25 x 1 INFORMATION DRAIN SIZE (INCHES) 3/4" 3/4" 3/4" EXPANSION DEVICE ORIFICE (0.057) ORIFICE (0.060) ORIFICE (0.065) 83 78 80 REFRIGERANT CHARGE R-410A (Oz.) 3/4, 1, 1-1/4 3/4, 1, 1-1/4 3/4, 1, 1-1/4 LOW VOLTAGE CONDUIT KNOCKOUT SIZE (INCHES) 1/2 1/2 1/2 SHIPPING WEIGHT LBS. 310 310 370 OPERATING WEIGHT LBS. 300 300 360 POWER SUPPLY CONDUIT KNOCKOUT SIZE (INCHES) (1) * Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. Calculated external filter size based on air velocity of 300 ft/min. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information. IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters. WARNING 8 All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent protection during refrigeration cycle. PACKAGE COOLING SPECIFICATIONS GPC14[42-60]H41* GPC1442H41* GPC1448H41* GPC1460H41* 40,500 46,500 57,500 COOLING COOLING CAPACITY, BTUH CAPACITY SEER / EER UNIT VOLTAGE (NAMEPLATE) ELECTRICAL AMPS (TOTAL) 22.2 24.2 30.7 SPECIFICATION MINIMUM CIRCUIT AMPACITY 26.6 29.1 37.3 MAXIMUM OVERCURRENT PROTECTION (1) COMPRESSOR 14.5 / 12.0 14.5 / 12.1 14.2 / 12.0 208-230/1/60 208-230/1/60 208-230/1/60 40 45 60 SCROLL SCROLL SCROLL RATED LOAD AMPS 17.9 19.9 26.4 LOCKED ROTOR AMPS 112 109 134 TYPE CONDENSER HORSEPOWER FAN MOTOR RPM FULL LOAD AMPS LOCKED ROTOR AMPS CONDENSER FAN BLADE DIAMETER (INCHES) / NUMBER OF BLADES CONDENSER FACE AREA - SQ. FT. COIL NUMBER OF ROWS FINS PER INCH 1/4 1/4 1/4 1075 1075 1075 1.4 1.4 1.4 2.9 2.9 2.9 22 / 4 22 / 4 22 / 4 17.0 19.1 19.1 1 1 2 24 21 16 1/2 - 5 3/4 - 5 3/4 - 5 FULL LOAD AMPS 2.9 2.9 2.9 LOCKED ROTOR AMPS NA NA NA EVAPORATOR HORSEPOWER - NO. OF SPEEDS BLOWER MOTOR MOTOR SPEED TAP - COOLING T2 T2 T2 RPM 1050 1050 1050 EVAPORATOR DIAMETER X W IDTH (INCHES) 10 x 8 10 x 8 11 x 8 BLOWER HI EFFICIENCY COOLING CFM 1,300 1,600 1,600 5 TON NOMINAL COOLING CFM NA NA 1,800 1,200 1,400 1,600 MAX EXTERNAL STATIC PRESS ("w.c.) 0.5 0.5 0.5 EVAPORATOR FACE AREA - SQ. FT. 6.2 6.2 7.0 COIL NUMBER OF ROWS 4 4 4 FAN ONLY COOLING CFM FINS PER INCH 14 14 14 (2) 20 x 20 x 1 (2) 20 x 20 x 1 (2) 20 x 25 x 1 GENERAL FILTER SIZE - SQ. FT. * INFORM ATION DRAIN SIZE (INCHES) 3/4" 3/4" 3/4" EXPANSION DEVICE ORIFICE (0.072) ORIFICE (0.076) ORIFICE (0.088) REFRIGERANT CHARGE R-410A (Oz.) POWER SUPPLY CONDUIT KNOCKOUT SIZE (INCHES) 118 123 188 3/4, 1, 1-1/4 3/4, 1, 1-1/4 3/4, 1, 1-1/4 LOW VOLTAGE CONDUIT KNOCKOUT SIZE (INCHES) 1/2 1/2 1/2 SHIPPING WEIGHT LBS. 370 400 400 OPERATING WEIGHT LBS. 360 390 390 (1) * Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. Calculated external filter size based on air velocity of 300 ft/min. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information. IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters. WARNING All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent protection during refrigeration cycle. 9 GPC14[24-60]H41A* ACCESSORIES ACCESSORIES - GPC/GPH****H UNITS Part Number Description OT18-60A Outdoor Thermostat Kit w/Lockout Stat OT/EHR18-60 Emergency Heat Relay Kit HKR Electric Heat Kit PCCP101-103 Roof Curb PCP101-103 Downflow Plenum Kit PCP101-103R8 Downflow Plenum Kit w/ R-8 Insulation PCEC101-103 Downflow Economizer for GPC-(H) A/C - To Be Used With PCP101-103 PCEH101-103 Downflow Economizer for GPH-(H) Heat Pump - To Be Used With PCP101-103 PCMD101-103 Manual Damper - To Be Used With PCP101-103 PCMDM101-103 Motorized Damper - To Be Used With PCP101-103 GPHMD101-103 Manual Damper for Horizontal Applications SQRPCH101 Square to Round Adapters 16"&14" SQRPCH102-103 Square to Round Adapters 18"&14" SQRPC101 Square to Round Adapter - For Use With PCCP101-103 Curb 16" Rounds SQRPC102-103 Square to Round Adapter For Use With PCCP101-103 Curb 18" Rounds PCFR101-103 External Horizontal Filter Rack PCEF101-103 Elbow & Flashing w/ R-8 Liner CDK36 Flush Mount Concentric Duct Kit CDK36515 Flush Mount Concentric Duct Kit w/ Filter CDK36530 Step Down Concentric Duct Kit CDK36535 Step Down Concentric Duct Kit w/ Filter CDK4872 Flush Mount Concentric Duct Kit CDK4872515 Flush Mount Concentric Duct Kit w/ Filter CDK4872530 Step Down Concentric Duct Kit CDK4872535 Step Down Concentric Duct Kit w/ Filter 10 GPC14[24-60]H41A* BLOWER PERFORMANCE DATA Dry Coil Data GPC1460H41** GPC1448H41** GPC1442H41** GPC1436H41** GPC1430H41** GPC1424H41** Model Speed T1 Volts 230 T2,T3 230 T4, T5 230 T1 230 T2,T3 230 T4, T5 230 T1 T2,T3 T4, T5 T1 T2,T3 T4, T5 T1 T2,T3 T4, T5 T1, T2, T3 T4, T5 230 230 230 230 230 230 230 230 230 230 230 E.S.P (In. of H2O) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM 934 759 755 638 581 489 - - WATTS 95 77 76 73 83 90 - - CFM 990 837 801 744 696 652 601 - WATTS 107 94 105 110 119 133 142 - CFM 1061 989 947 925 876 - - - WATTS 126 134 146 158 169 - - - CFM 1022 929 894 829 797 748 695 643 WATTS 116 114 126 134 144 156 168 173 CFM 1103 1063 1012 962 937 - - - WATTS 142 154 165 173 185 - - - CFM 1285 1240 1202 1163 1124 1076 1046 1003 WATTS 205 218 231 244 257 268 280 288 CFM 1234 1111 1071 1024 933 922 - - WATTS 144 140 152 164 179 183 - - CFM 1287 1232 1186 1133 1099 1053 - - WATTS 162 175 187 201 213 221 - - CFM 1381 1325 1277 1233 1181 1144 - - WATTS 195 203 217 233 247 258 - - CFM 1272 1197 1145 1106 1055 998 947 906 WATTS 160 168 183 191 211 220 230 243 CFM 1357 1297 1244 1194 1147 1099 1049 1008 WATTS 188 202 213 228 245 255 267 284 CFM 1537 1478 1431 1386 1336 1293 1253 1208 WATTS 244 258 274 288 303 317 329 341 CFM 1418 1383 1349 1312 1275 1228 1178 1141 WATTS 242 258 273 282 299 308 320 338 CFM 1175 1635 1645 1515 1510 1450 1430 1400 WATTS 395 420 435 445 455 465 470 475 CFM 1845 1790 1715 1685 1590 1580 1530 1500 WATTS 490 505 520 535 550 560 570 575 CFM 1775 1635 1645 1515 1510 1450 1430 1400 WATTS 395 420 435 445 455 465 470 475 CFM 2025 1900 1840 1780 1725 1650 1620 1580 WATTS 575 595 620 630 645 655 660 670 NOTES: 1. Data shown is dry coil. Wet coil pressure drop is approx. 2. 0.1" H2 O, for 2 row indoor coil; 0.2” H2O, for 3 row indoor coil; and 0.3” H2 O, for 4 row indoor coil. 3. Data shown does not include filter pressure drop, approx. 0.08” H2 O. 4. Reduce airflow by 2% for 208V operation. 11 12 10 20 30 40 50 60 70 30 80 90 100 40 50 60 700 600 CFM 90 100 2000 2200 2400 CFM 1800 1600 1400 OUTPUT BTU/HR x 1000 80 1200 1100 1000 900 70 800 FORMULAS 110 120 130 140 BTU OUTPUT = CFM x 1.08 x RISE BTU OUTPUT RISE = ÷ CFM 1.08 BTU OUTPUT vs TEMPERATURE RISE CHART 150 BLOWER PERFORMANCE DATA TEMPERATURE RISE EXPANDED PERFORMANCE DATA 21.6 0.68 18 1.52 6.4 224 107 24.5 0.84 20 1.58 6.7 236 112 23.8 0.81 21 1.57 6.6 233 111 22.0 0.78 21 1.53 6.5 226 108 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 850 745 955 850 745 22.6 0.69 19 1.56 6.6 244 115 24.5 0.72 19 1.60 6.8 251 118 25.2 0.76 18 1.62 6.8 254 120 22.4 0.57 16 1.55 6.6 241 114 24.3 0.59 16 1.59 6.7 249 117 24.5 0.53 16 1.61 6.8 257 125 26.5 0.55 16 1.66 7.0 265 129 27.3 0.57 15 1.67 7.1 268 131 24.5 0.40 12 1.60 6.8 255 124 26.6 0.41 12 1.64 6.9 263 128 26.3 0.34 11 1.67 7.1 268 134 28.5 0.35 11 1.71 7.2 277 138 29.3 0.37 10 1.73 7.3 279 139 - - 21.5 0.81 21 1.65 7.0 254 114 23.2 0.83 21 1.70 7.1 262 118 23.9 0.88 20 1.71 7.2 265 119 21.1 0.71 18 1.64 6.9 252 113 22.9 0.73 18 1.68 7.1 259 116 22.1 0.72 20 1.69 7.1 273 121 23.9 0.75 19 1.73 7.3 282 125 24.7 0.78 19 1.75 7.4 285 126 21.9 0.59 16 1.68 7.1 271 120 23.7 0.61 16 1.72 7.2 279 124 * IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction access fittings. 75 70 23.4 0.71 18 1.56 6.6 231 110 MBh S/T Delta T KW AMPS HI PR LO PR 25.7 0.35 11 1.81 7.6 301 141 27.8 0.36 11 1.85 7.8 310 145 28.6 0.38 11 1.87 7.9 314 147 - - 20.9 0.83 21 1.76 7.5 289 119 22.7 0.86 21 1.81 7.7 298 122 23.4 0.90 20 1.82 7.8 301 123 20.6 0.73 18 1.75 7.5 286 117 22.3 0.75 18 1.79 7.7 295 121 21.6 0.74 20 1.80 7.7 311 126 23.4 0.77 19 1.85 7.9 321 130 24.1 0.80 19 1.87 8.0 324 131 21.3 0.61 16 1.79 7.6 308 125 23.1 0.63 16 1.83 7.8 317 129 23.3 0.56 16 1.86 7.9 328 138 25.3 0.58 16 1.91 8.1 339 142 26.0 0.61 15 1.93 8.2 342 143 23.4 0.42 12 1.85 7.9 325 136 25.3 0.44 12 1.90 8.1 335 141 25.1 0.36 11 1.93 8.2 343 147 27.1 0.37 11 1.98 8.4 353 151 28.0 0.39 11 2.00 8.5 357 153 - - 20.4 0.85 21 1.86 8.0 329 125 22.1 0.88 21 1.91 8.2 339 128 22.8 0.93 20 1.92 8.3 343 130 20.1 0.75 19 1.84 7.9 326 123 21.8 0.78 18 1.89 8.1 336 127 NOTE: Shaded area is ACCA (TVA) conditions 23.9 0.55 16 1.75 7.3 289 133 25.9 0.57 16 1.79 7.5 298 137 26.7 0.59 15 1.81 7.6 301 138 24.0 0.41 12 1.73 7.3 286 131 26.0 0.42 12 1.78 7.5 295 135 21.0 0.76 20 1.90 8.2 354 133 22.8 0.58 16 1.97 8.4 374 145 24.7 0.60 16 2.02 8.7 386 149 25.4 0.63 15 2.04 8.7 389 151 23.5 0.83 19 1.97 8.5 369 138 22.8 0.79 19 1.95 8.4 365 137 22.8 0.43 12 1.95 8.4 370 143 24.7 0.45 12 2.00 8.6 382 148 20.8 0.63 16 1.88 8.1 351 131 22.6 0.65 16 1.93 8.3 361 135 24.4 0.37 11 2.03 8.7 390 154 26.5 0.38 11 2.09 9.0 402 159 27.3 0.40 11 2.11 9.1 406 160 - - 19.4 0.88 21 1.94 8.5 370 131 21.0 0.92 21 1.99 8.7 382 135 21.7 0.96 20 2.01 8.8 386 136 19.1 0.78 18 1.92 8.4 367 129 20.7 0.81 18 1.97 8.6 378 133 20.0 0.79 20 1.98 8.7 398 139 21.7 0.82 19 2.04 8.9 411 143 22.3 0.86 18 2.06 9.0 415 145 19.8 0.65 16 1.97 8.6 394 137 21.4 0.67 16 2.02 8.8 407 142 21.6 0.60 16 2.05 9.0 421 152 23.4 0.62 16 2.11 9.2 434 156 24.1 0.65 15 2.13 9.3 438 158 21.7 0.45 12 2.03 8.9 417 150 23.5 0.47 12 2.09 9.1 429 155 23.2 0.39 11 2.12 9.3 439 161 25.2 0.40 11 2.18 9.5 452 166 25.9 0.42 10 2.20 9.6 457 168 - - 18.0 0.89 20 2.01 9.0 409 135 19.5 0.92 19 2.06 9.2 422 139 20.1 0.97 19 2.08 9.3 426 141 17.7 0.78 17 1.99 8.9 405 134 19.2 0.81 17 2.05 9.1 418 138 18.5 0.80 18 2.06 9.2 440 144 20.1 0.83 18 2.11 9.4 454 148 20.7 0.87 17 2.13 9.5 458 150 18.3 0.66 15 2.04 9.1 436 142 19.9 0.68 15 2.09 9.3 449 147 63 20.5 0.71 14 2.11 9.4 454 148 20.0 0.60 15 2.13 9.5 465 157 21.7 0.63 15 2.19 9.7 479 162 22.4 0.66 14 2.20 9.8 484 163 20.1 0.45 11 2.11 9.4 460 155 21.8 0.47 11 2.17 9.6 474 160 67 22.4 0.49 11 2.19 9.7 479 162 115 21.5 0.39 10 2.20 9.8 485 167 23.3 0.40 10 2.26 10.1 500 172 24.0 0.42 10 2.28 10.2 505 174 - - 71 - COOLING OPERATION Design Subcooling, 9 ± 2°F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 5 ± 2°F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MBh 24.1 25.0 27.4 23.5 24.4 26.7 23.0 23.8 26.1 22.4 23.2 25.5 21.3 22.1 24.2 19.7 S/T 0.74 0.62 0.43 0.77 0.64 0.45 0.79 0.66 0.46 0.82 0.68 0.47 0.85 0.71 0.49 0.85 Delta T 17 15 11 17 15 11 17 15 11 18 15 12 17 15 11 16 955 KW 1.57 1.60 1.66 1.70 1.73 1.79 1.81 1.85 1.91 1.91 1.95 2.02 1.99 2.04 2.11 2.06 AMPS 6.6 6.8 7.0 7.1 7.3 7.5 7.7 7.9 8.1 8.2 8.4 8.7 8.7 8.9 9.2 9.2 HI PR 233 251 265 262 282 298 298 321 338 339 365 386 382 411 434 422 LO PR 111 118 129 118 125 137 122 130 142 128 137 149 135 143 156 139 MODEL: GPC1424H41A* COOLING PERFORMANCE DATA GPC1424H41A* 13 14 EXPANDED PERFORMANCE DATA 85 80 22.4 0.85 24 1.54 6.5 229 109 25.4 0.97 24 1.61 6.8 241 115 24.6 0.93 25 1.60 6.8 238 114 22.7 0.89 25 1.56 6.6 231 110 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 850 745 955 850 745 23.2 0.86 25 1.59 6.7 249 117 25.1 0.89 24 1.63 6.9 256 121 25.9 0.94 23 1.64 7.0 259 122 22.8 0.80 23 1.58 6.7 246 116 24.8 0.83 22 1.62 6.8 254 120 24.3 0.78 23 1.64 6.9 263 128 26.3 0.81 23 1.69 7.1 271 132 27.1 0.85 22 1.70 7.2 273 133 24.4 0.65 20 1.63 6.9 260 127 26.4 0.67 19 1.67 7.1 268 131 25.9 0.63 20 1.70 7.2 274 136 28.1 0.65 20 1.74 7.4 282 140 28.9 0.69 19 1.76 7.4 285 142 26.1 0.49 16 1.68 7.1 271 135 28.3 0.50 15 1.73 7.3 279 139 22.2 0.93 25 1.68 7.1 259 116 24.1 0.96 25 1.72 7.3 267 120 24.8 1.00 24 1.74 7.3 270 121 21.8 0.88 24 1.67 7.0 257 115 23.7 0.92 23 1.71 7.2 265 119 22.6 0.89 25 1.72 7.2 279 124 24.5 0.93 25 1.76 7.4 288 128 25.3 0.97 24 1.78 7.5 290 129 22.3 0.83 23 1.70 7.2 276 123 24.2 0.86 22 1.75 7.4 285 126 23.7 0.81 24 1.78 7.5 295 135 25.7 0.84 23 1.82 7.7 304 139 26.5 0.88 22 1.84 7.7 307 141 23.8 0.67 20 1.76 7.4 292 134 25.8 0.70 20 1.81 7.6 301 138 25.3 0.65 20 1.84 7.7 307 144 27.4 0.68 20 1.89 7.9 317 148 28.2 0.71 19 1.90 8.0 320 150 25.5 0.50 16 1.82 7.7 304 143 27.6 0.52 16 1.87 7.9 314 147 21.7 0.95 25 1.79 7.7 295 121 23.5 0.98 25 1.84 7.9 304 125 24.2 1.00 23 1.86 7.9 307 126 21.3 0.91 24 1.78 7.6 292 120 23.1 0.94 23 1.82 7.8 301 123 22.1 0.92 25 1.83 7.8 317 129 24.0 0.95 25 1.88 8.0 327 133 24.7 1.00 24 1.90 8.1 330 134 21.8 0.85 23 1.82 7.8 314 127 NOTE: 23.6 0.88 22 1.87 8.0 324 131 27.0 0.54 16 2.00 8.5 357 153 22.5 0.97 24 1.92 8.3 343 130 23.0 0.91 23 1.97 8.5 369 138 24.6 0.74 20 2.04 8.8 390 151 26.3 0.55 16 2.11 9.1 406 160 23.2 0.83 24 1.90 8.1 335 141 25.1 0.86 23 1.95 8.3 345 145 25.8 0.90 22 1.96 8.4 349 146 24.7 0.67 20 1.96 8.4 349 150 26.8 0.70 20 2.01 8.6 360 154 27.6 0.73 19 2.03 8.7 364 156 21.2 0.98 26 1.89 8.1 336 127 22.9 1.00 25 1.94 8.4 346 131 23.6 1.00 23 1.96 8.4 350 132 21.6 0.95 25 1.93 8.3 361 135 23.4 0.98 25 1.99 8.6 373 139 24.1 1.00 23 2.00 8.6 376 141 22.6 0.85 24 2.00 8.6 382 148 24.5 0.88 23 2.05 8.8 393 152 25.2 0.93 23 2.07 8.9 397 154 24.1 0.69 21 2.07 8.9 398 157 26.1 0.72 20 2.13 9.1 410 162 26.9 0.75 19 2.14 9.2 414 164 23.3 24.9 20.8 21.3 22.7 24.3 0.69 0.52 0.93 0.88 0.71 0.53 20 16 24 23 20 16 1.88 1.94 1.87 1.92 1.98 2.05 8.0 8.3 8.1 8.3 8.5 8.8 332 346 332 358 378 394 139 148 126 134 146 156 Shaded area reflects AHRI rating conditions 25.2 0.72 20 1.93 8.2 342 143 20.1 1.00 25 1.97 8.6 378 133 21.8 1.00 24 2.03 8.9 389 137 22.4 1.00 22 2.04 8.9 393 139 19.8 0.97 24 1.96 8.6 374 132 21.4 1.00 23 2.01 8.8 386 136 20.5 0.98 25 2.02 8.8 407 142 22.2 1.00 24 2.07 9.1 419 146 22.9 1.00 22 2.09 9.2 423 148 20.2 0.91 23 2.00 8.8 403 140 21.9 0.94 22 2.06 9.0 415 145 21.5 0.89 23 2.09 9.1 429 155 23.3 0.92 23 2.15 9.4 443 159 24.0 0.96 22 2.16 9.5 447 161 21.6 0.74 20 2.07 9.0 425 153 23.4 0.77 19 2.13 9.3 438 158 * NOTE: Shaded area is AHRI Rating Conditions IDB: Entering Indoor Dry Bulb Temperature KW = Total system power High and low pressures are measured at the liquid and suction access fittings. AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 24.2 0.88 23 1.58 6.7 236 112 MBh S/T Delta T KW AMPS HI PR LO PR 22.9 0.72 20 2.16 9.4 448 165 24.8 0.75 20 2.22 9.7 462 170 25.6 0.78 19 2.24 9.8 466 172 23.1 0.55 16 2.14 9.4 443 163 25.0 0.57 16 2.20 9.6 457 168 18.6 1.00 23 2.05 9.1 417 138 20.2 1.00 22 2.10 9.4 430 142 20.8 1.00 20 2.12 9.5 435 143 18.3 0.98 22 2.03 9.0 413 136 19.8 1.00 21 2.08 9.3 426 141 19.0 0.99 23 2.09 9.3 449 147 20.6 1.00 22 2.15 9.6 463 151 21.2 1.00 20 2.17 9.7 468 153 18.7 0.92 21 2.07 9.3 445 145 20.3 0.95 21 2.13 9.5 458 150 63 20.9 1.00 20 2.15 9.6 463 151 19.9 0.89 22 2.17 9.6 474 160 21.5 0.93 22 2.22 9.9 489 165 22.2 0.97 21 2.24 10.0 494 167 20.0 0.75 18 2.15 9.6 470 158 21.6 0.77 18 2.21 9.8 484 163 67 22.3 0.81 17 2.22 9.9 489 165 115 21.2 0.72 19 2.24 10.0 495 170 23.0 0.75 19 2.30 10.3 510 176 23.7 0.79 18 2.32 10.4 515 177 21.4 0.56 15 2.22 9.9 490 169 23.1 0.58 14 2.28 10.2 505 174 71 23.8 0.61 14 2.30 10.3 510 176 COOLING OPERATION Design Subcooling, 9 ± 2°F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 5 ± 2°F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MBh 25.0 25.5 27.2 29.1 24.4 24.9 26.6 28.4 23.8 24.3 26.0 27.8 23.2 23.7 25.3 27.1 22.0 22.5 24.1 25.7 20.4 S/T 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 1.00 0.92 0.75 0.56 1.00 0.95 0.78 0.58 1.00 1.00 0.81 0.60 1.00 Delta T 22 21 19 15 23 22 19 15 23 22 19 15 22 22 19 15 21 22 19 15 20 955 KW 1.60 1.63 1.69 1.74 1.72 1.76 1.82 1.89 1.84 1.88 1.95 2.01 1.94 1.99 2.05 2.13 2.03 2.07 2.15 2.22 2.10 AMPS 6.8 6.9 7.1 7.4 7.3 7.4 7.7 7.9 7.9 8.0 8.3 8.6 8.4 8.6 8.8 9.1 8.9 9.1 9.4 9.7 9.4 HI PR 238 256 271 282 267 288 304 317 304 327 345 360 346 373 393 410 389 419 443 462 430 LO PR 114 121 132 140 120 128 139 148 125 133 145 154 131 139 152 162 137 146 159 170 142 MODEL: GPC1424H41A* COOLING PERFORMANCE DATA GPC1424H41A* EXPANDED PERFORMANCE DATA 27.5 0.82 20 1.86 7.7 240 111 25.4 0.79 20 1.81 7.5 232 108 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1180 920 1050 28.3 0.86 19 1.88 7.8 242 113 MBh S/T Delta T KW AMPS HI PR LO PR 920 28.3 0.74 18 1.90 7.9 258 119 26.1 0.71 19 1.85 7.7 250 115 29.1 0.77 18 1.92 7.9 260 120 25.8 0.58 15 1.84 7.6 248 114 30.6 0.56 15 1.96 8.1 272 129 28.3 0.54 15 1.92 7.9 264 126 31.5 0.58 14 1.98 8.2 275 131 28.3 0.40 11 1.90 7.8 261 124 32.9 0.36 10 2.03 8.4 284 138 30.3 0.35 10 1.98 8.2 275 134 33.9 0.38 10 2.05 8.5 287 139 - 26.8 0.85 20 2.01 8.3 269 118 24.8 0.82 20 1.96 8.1 261 114 27.6 0.90 19 2.03 8.3 272 119 24.4 0.72 18 1.94 8.0 258 113 27.6 0.76 18 2.06 8.5 289 125 25.5 0.74 19 2.00 8.2 281 121 28.5 0.80 18 2.07 8.5 292 126 25.2 0.61 15 1.99 8.2 278 120 * IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction access fittings. 75 24.9 0.70 17 1.80 7.4 230 107 MBh S/T Delta T KW AMPS HI PR LO PR 32.1 0.37 10 2.20 9.0 319 146 29.6 0.36 11 2.14 8.8 309 141 33.1 0.39 10 2.22 9.1 322 147 - 26.2 0.88 20 2.14 8.9 306 122 24.2 0.84 20 2.09 8.7 297 119 27.0 0.92 19 2.16 9.0 309 124 23.8 0.74 18 2.07 8.6 294 117 27.0 0.78 19 2.19 9.1 329 130 24.9 0.76 19 2.14 8.9 319 126 27.8 0.82 18 2.21 9.2 332 131 24.6 0.62 15 2.12 8.8 316 125 29.2 0.59 15 2.27 9.4 347 142 26.9 0.57 15 2.21 9.2 337 138 30.1 0.62 15 2.29 9.5 351 143 27.0 0.43 12 2.19 9.1 334 136 31.3 0.38 10 2.34 9.8 362 151 28.9 0.37 11 2.28 9.5 351 147 32.3 0.40 10 2.36 9.8 366 153 - 25.6 0.90 20 2.26 9.5 348 128 23.6 0.87 21 2.20 9.3 338 125 26.3 0.95 19 2.28 9.6 352 130 23.2 0.77 18 2.18 9.2 334 123 NOTE: Shaded area is ACCA (TVA) conditions 29.9 0.58 15 2.12 8.7 305 137 27.6 0.56 15 2.07 8.5 296 133 30.8 0.61 15 2.14 8.8 309 138 27.7 0.42 12 2.05 8.4 293 131 28.5 0.61 15 2.39 10.0 396 149 26.3 0.59 16 2.33 9.8 384 145 29.3 0.64 15 2.41 10.1 400 151 27.1 0.85 18 2.33 9.8 378 138 26.3 0.81 19 2.31 9.7 375 137 24.3 0.78 19 2.25 9.5 363 133 26.3 0.44 12 2.31 9.7 380 143 24.0 0.64 15 2.23 9.4 360 131 30.6 0.39 11 2.47 10.4 413 159 28.2 0.38 11 2.41 10.1 400 154 31.5 0.41 10 2.49 10.5 417 161 - 24.3 0.94 20 2.36 10.1 392 135 22.4 0.90 20 2.30 9.8 380 131 25.0 0.98 19 2.38 10.2 396 136 22.0 0.80 18 2.28 9.7 376 129 25.0 0.84 18 2.41 10.3 422 143 23.1 0.81 19 2.35 10.1 409 139 25.8 0.88 18 2.43 10.4 426 145 22.8 0.66 15 2.33 10.0 405 138 27.1 0.64 15 2.50 10.7 445 156 25.0 0.61 15 2.43 10.4 432 152 27.9 0.67 14 2.52 10.7 450 158 25.0 0.46 12 2.41 10.3 427 150 29.0 0.41 10 2.58 11.0 464 167 26.8 0.39 11 2.52 10.7 450 162 29.9 0.43 10 2.61 11.1 469 168 - 22.5 0.95 19 2.44 10.7 433 139 20.8 0.91 19 2.38 10.4 420 135 23.2 0.99 18 2.47 10.8 437 141 20.4 0.80 16 2.36 10.3 416 134 23.2 0.85 17 2.50 10.9 466 148 21.4 0.82 17 2.44 10.6 452 144 23.9 0.89 16 2.52 11.0 470 150 21.2 0.67 14 2.41 10.5 447 142 63 23.6 0.73 13 2.50 10.9 466 148 22.9 0.70 14 2.48 10.8 461 147 25.1 0.64 14 2.59 11.3 492 162 23.1 0.62 14 2.52 11.0 477 157 25.8 0.67 14 2.61 11.4 497 163 23.2 0.46 11 2.50 10.9 472 155 67 25.9 0.50 10 2.59 11.3 492 162 25.1 0.48 11 2.56 11.2 487 160 115 26.9 0.41 10 2.68 11.7 513 172 24.8 0.40 10 2.61 11.4 498 167 27.7 0.43 9 2.70 11.8 518 174 - 71 - COOLING OPERATION Design Subcooling, 10 ± 2 °F @ the liquid access fitting connection ARI 95 test conditions. Design Superheat 10 ± 2 °F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MBh 27.8 28.8 31.6 27.2 28.2 30.9 26.5 27.5 30.1 25.9 26.8 29.4 24.6 25.5 27.9 22.8 S/T 0.76 0.63 0.44 0.79 0.66 0.46 0.81 0.67 0.47 0.83 0.70 0.48 0.87 0.72 0.50 0.87 Delta T 16 14 11 17 14 11 17 14 11 17 15 11 17 14 11 15 1180 KW 1.86 1.90 1.96 2.01 2.06 2.12 2.14 2.19 2.27 2.26 2.31 2.39 2.36 2.41 2.50 2.44 AMPS 7.7 7.9 8.1 8.3 8.5 8.7 8.9 9.1 9.4 9.5 9.7 10.0 10.1 10.3 10.7 10.7 HI PR 240 258 272 269 289 305 306 329 347 348 375 396 392 421 445 433 LO PR 111 119 129 118 125 137 122 130 142 128 137 149 135 143 156 139 MBh 27.0 28.0 30.7 26.4 27.4 30.0 25.8 26.7 29.3 25.1 26.1 28.5 23.9 24.7 27.1 22.1 S/T 0.73 0.61 0.42 0.75 0.63 0.43 0.77 0.64 0.45 0.80 0.66 0.46 0.83 0.69 0.48 0.83 Delta T 17 15 11 17 15 11 17 15 11 18 15 11 17 15 11 16 70 1050 KW 1.84 1.89 1.95 1.99 2.04 2.11 2.12 2.17 2.25 2.24 2.29 2.37 2.34 2.39 2.47 2.42 AMPS 7.6 7.8 8.0 8.2 8.4 8.6 8.9 9.1 9.3 9.4 9.6 10.0 10.0 10.2 10.6 10.6 HI PR 237 255 269 266 286 302 303 326 344 345 371 392 388 417 441 428 LO PR 110 117 128 117 124 135 121 129 141 127 135 148 133 142 155 138 MODEL: GPC1430H41A* COOLING PERFORMANCE DATA GPC1430H41A* 15 16 EXPANDED PERFORMANCE DATA 85 80 25.8 0.87 22 1.83 7.6 235 109 29.3 0.99 23 1.91 7.9 247 115 28.5 0.95 24 1.89 7.8 244 114 26.3 0.91 24 1.84 7.6 237 110 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1050 920 1180 1050 920 26.8 0.88 24 1.89 7.8 255 117 29.0 0.91 23 1.93 8.0 263 121 29.9 0.96 22 1.95 8.1 266 122 26.4 0.82 22 1.87 7.7 253 116 28.6 0.85 21 1.92 7.9 260 120 28.0 0.80 22 1.95 8.0 269 128 30.4 0.83 22 2.00 8.2 278 132 31.3 0.87 21 2.01 8.3 281 133 28.2 0.67 19 1.93 8.0 267 127 30.5 0.69 18 1.98 8.2 275 131 29.9 0.65 19 2.01 8.3 281 136 32.4 0.67 19 2.07 8.5 290 141 33.4 0.70 18 2.08 8.6 293 142 30.1 0.50 15 2.00 8.2 278 135 32.6 0.52 15 2.05 8.5 287 139 25.7 0.95 24 1.99 8.2 266 116 27.8 0.98 24 2.04 8.4 274 120 28.6 1.00 22 2.06 8.5 277 121 25.2 0.90 23 1.98 8.1 263 115 27.3 0.94 22 2.03 8.3 272 119 26.1 0.91 24 2.04 8.4 286 124 28.3 0.95 24 2.09 8.6 295 128 29.2 0.99 23 2.11 8.7 298 129 25.8 0.85 22 2.02 8.3 283 123 27.9 0.88 21 2.07 8.5 292 126 27.4 0.82 23 2.11 8.6 302 135 29.7 0.86 22 2.16 8.9 312 139 30.6 0.90 21 2.18 8.9 315 141 27.5 0.69 19 2.09 8.6 299 134 29.8 0.72 19 2.14 8.8 309 138 29.2 0.67 20 2.18 8.9 315 144 31.7 0.69 19 2.23 9.2 325 149 32.6 0.73 18 2.25 9.3 328 150 29.4 0.52 15 2.16 8.9 312 143 31.9 0.53 15 2.22 9.1 322 147 25.0 0.97 24 2.12 8.9 303 121 27.1 1.00 24 2.18 9.1 312 125 27.9 1.00 22 2.20 9.2 315 126 24.6 0.93 23 2.11 8.8 300 120 26.7 0.96 22 2.16 9.0 309 124 25.5 0.94 24 2.17 9.1 326 129 27.7 0.97 24 2.23 9.3 336 133 28.5 1.00 22 2.25 9.4 339 134 25.1 0.87 22 2.15 9.0 322 128 NOTE: 27.2 0.90 21 2.21 9.2 332 131 31.1 0.55 15 2.36 9.8 366 153 26.0 0.99 23 2.28 9.6 352 130 26.6 0.93 22 2.33 9.8 379 138 28.4 0.76 19 2.41 10.1 400 151 30.4 0.57 15 2.49 10.5 417 161 26.7 0.85 23 2.25 9.3 344 141 29.0 0.88 22 2.30 9.6 354 145 29.8 0.92 21 2.32 9.7 358 146 28.5 0.69 20 2.32 9.7 359 150 30.9 0.71 19 2.38 9.9 370 154 31.8 0.75 18 2.41 10.0 373 156 24.4 1.00 24 2.24 9.4 345 127 26.5 1.00 23 2.30 9.7 355 131 27.3 1.00 21 2.32 9.8 359 132 24.9 0.97 24 2.29 9.6 371 135 27.0 1.00 24 2.35 9.9 382 139 27.8 1.00 22 2.37 10.0 386 141 26.1 0.87 23 2.37 10.0 392 148 28.3 0.91 22 2.43 10.2 404 152 29.1 0.95 22 2.45 10.3 408 154 27.8 0.71 20 2.45 10.3 408 157 30.1 0.73 19 2.52 10.6 421 162 31.1 0.77 19 2.54 10.7 425 164 26.9 28.7 24.0 24.5 26.2 28.0 0.71 0.53 0.96 0.90 0.73 0.55 19 15 23 22 19 15 2.23 2.30 2.22 2.27 2.35 2.43 9.3 9.6 9.3 9.6 9.9 10.2 340 355 341 367 388 404 139 148 126 134 146 156 Shaded area reflects AHRI rating conditions 29.1 0.73 19 2.29 9.5 351 144 23.2 1.00 23 2.34 10.0 388 133 25.1 1.00 22 2.40 10.3 400 137 25.9 1.00 20 2.42 10.4 404 139 22.8 0.99 23 2.32 9.9 384 132 24.7 1.00 22 2.38 10.2 396 136 23.7 1.00 24 2.39 10.2 417 142 25.6 1.00 22 2.46 10.5 430 146 26.4 1.00 21 2.48 10.6 434 148 23.3 0.93 22 2.37 10.1 413 140 25.3 0.97 21 2.43 10.4 426 145 24.8 0.91 22 2.47 10.6 441 155 26.8 0.94 22 2.54 10.8 454 160 27.7 0.99 21 2.56 10.9 459 161 24.9 0.76 19 2.45 10.5 436 153 27.0 0.79 19 2.52 10.7 450 158 * NOTE: Shaded area is AHRI Rating Conditions IDB: Entering Indoor Dry Bulb Temperature KW = Total system power High and low pressures are measured at the liquid and suction access fittings. AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 28.0 0.90 22 1.88 7.8 242 113 MBh S/T Delta T KW AMPS HI PR LO PR 26.4 0.73 19 2.56 10.9 459 165 28.6 0.76 19 2.63 11.2 474 170 29.5 0.80 18 2.65 11.3 478 172 26.6 0.57 15 2.54 10.8 455 163 28.8 0.59 15 2.61 11.1 469 168 21.5 1.00 21 2.42 10.6 428 138 23.3 1.00 20 2.49 10.9 442 142 24.0 1.00 19 2.51 10.9 446 144 21.1 1.00 21 2.40 10.5 424 136 22.9 1.00 20 2.47 10.8 437 141 21.9 1.00 22 2.48 10.8 461 147 23.7 1.00 21 2.55 11.1 475 151 24.5 1.00 19 2.57 11.2 480 153 21.6 0.94 20 2.46 10.7 456 145 23.4 0.97 20 2.52 11.0 470 150 63 24.1 1.00 19 2.55 11.1 475 151 23.0 0.91 21 2.56 11.2 487 160 24.9 0.95 21 2.63 11.5 502 165 25.6 0.99 20 2.66 11.6 507 167 23.1 0.76 18 2.54 11.1 482 159 25.0 0.79 17 2.61 11.4 497 163 67 25.7 0.83 17 2.63 11.5 502 165 115 24.5 0.74 18 2.65 11.6 508 171 26.5 0.77 18 2.73 11.9 523 176 27.3 0.81 17 2.75 12.0 529 178 24.7 0.57 14 2.63 11.5 503 169 26.7 0.59 14 2.70 11.8 518 174 71 27.5 0.62 13 2.73 11.9 523 176 COOLING OPERATION Design Subcooling, 10 ± 2 °F @ the liquid access fitting connection ARI 95 test conditions. Design Superheat 10 ± 2 °F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MBh 28.8 29.4 31.4 33.6 28.1 28.7 30.7 32.8 27.5 28.1 30.0 32.1 26.8 27.4 29.3 31.3 25.5 26.0 27.8 29.7 23.6 S/T 0.95 0.89 0.72 0.54 1.00 0.92 0.75 0.56 1.00 0.94 0.77 0.57 1.00 1.00 0.79 0.59 1.00 1.00 0.82 0.62 1.00 Delta T 21 20 18 14 22 21 18 14 21 21 18 14 21 21 18 14 20 20 18 14 18 1180 KW 1.89 1.93 2.00 2.07 2.04 2.09 2.16 2.23 2.18 2.23 2.30 2.38 2.30 2.35 2.43 2.52 2.40 2.46 2.54 2.63 2.49 AMPS 7.8 8.0 8.2 8.5 8.4 8.6 8.9 9.2 9.1 9.3 9.6 9.9 9.7 9.9 10.2 10.6 10.3 10.5 10.8 11.2 10.9 HI PR 244 263 278 290 274 295 312 325 312 336 354 370 355 382 404 421 400 430 454 474 442 LO PR 114 121 132 141 120 128 139 149 125 133 145 154 131 139 152 162 137 146 160 170 142 MODEL: GPC1430H41A* COOLING PERFORMANCE DATA GPC1430H41A* EXPANDED PERFORMANCE DATA 34.4 0.83 22 2.33 10.5 238 107 31.8 0.80 22 2.27 10.3 231 104 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1349 1052 1200 35.5 0.87 21 2.35 10.6 241 109 MBh S/T Delta T KW AMPS HI PR LO PR 1052 35.5 0.74 20 2.38 10.8 256 114 32.7 0.71 20 2.32 10.5 249 111 36.5 0.77 19 2.40 10.8 259 116 32.4 0.58 17 2.30 10.4 246 110 38.4 0.56 16 2.45 11.0 271 125 35.4 0.54 17 2.39 10.8 263 121 39.5 0.59 16 2.47 11.1 273 126 35.5 0.41 13 2.37 10.7 260 120 41.2 0.36 11 2.54 11.4 282 133 38.0 0.35 12 2.47 11.1 274 129 42.4 0.38 11 2.56 11.5 285 134 - 33.6 0.86 22 2.51 11.3 267 114 31.1 0.83 22 2.45 11.0 259 110 34.7 0.90 21 2.53 11.3 270 115 30.5 0.73 19 2.43 10.9 257 109 34.6 0.77 20 2.57 11.5 288 121 32.0 0.74 21 2.50 11.2 279 117 35.7 0.80 20 2.59 11.6 290 122 31.6 0.61 17 2.48 11.1 276 116 * IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction access fittings. 75 31.3 0.70 19 2.25 10.2 229 103 MBh S/T Delta T KW AMPS HI PR LO PR 40.2 0.37 11 2.74 12.2 317 140 37.1 0.36 12 2.67 11.9 307 136 41.4 0.39 11 2.76 12.3 320 142 - 32.8 0.88 22 2.67 12.1 304 118 30.3 0.85 22 2.60 11.8 295 114 33.8 0.92 21 2.69 12.2 307 119 29.8 0.74 19 2.58 11.7 292 113 33.8 0.78 20 2.73 12.3 327 126 31.2 0.76 21 2.66 12.0 317 122 34.8 0.82 20 2.75 12.4 330 127 30.9 0.62 17 2.64 11.9 314 121 36.6 0.59 17 2.82 12.7 345 137 33.8 0.57 17 2.75 12.4 335 133 37.7 0.62 16 2.84 12.8 349 138 33.8 0.43 13 2.73 12.3 332 132 39.3 0.38 11 2.92 13.1 360 146 36.3 0.37 12 2.84 12.8 349 142 40.5 0.40 11 2.94 13.2 364 147 - 32.0 0.91 22 2.81 12.8 346 124 29.6 0.87 23 2.74 12.5 336 120 33.0 0.95 21 2.84 12.9 350 125 29.1 0.77 20 2.72 12.4 332 119 NOTE: Shaded area is ACCA (TVA) conditions 37.5 0.58 17 2.65 11.8 304 132 34.6 0.56 17 2.58 11.5 295 128 38.6 0.61 16 2.67 11.9 307 133 34.7 0.42 13 2.56 11.4 292 127 35.7 0.61 17 2.97 13.4 393 144 33.0 0.59 17 2.90 13.1 382 140 36.8 0.64 16 3.00 13.5 397 145 34.0 0.85 20 2.90 13.2 376 133 33.0 0.81 20 2.88 13.1 373 132 30.4 0.78 21 2.80 12.7 361 128 33.0 0.44 13 2.87 13.0 378 138 30.1 0.64 17 2.78 12.6 358 127 38.3 0.39 12 3.07 13.9 410 153 35.4 0.38 12 2.99 13.5 398 149 39.5 0.41 11 3.10 14.0 414 155 - 30.4 0.94 22 2.93 13.5 389 130 28.1 0.91 22 2.86 13.2 378 126 31.4 0.99 21 2.96 13.6 393 131 27.6 0.80 19 2.84 13.1 374 125 31.3 0.84 20 3.00 13.8 419 138 28.9 0.81 21 2.92 13.4 407 134 32.3 0.88 19 3.03 13.9 423 140 28.6 0.67 17 2.90 13.3 402 133 33.9 0.64 17 3.10 14.2 443 151 31.3 0.61 17 3.02 13.8 429 146 34.9 0.67 16 3.13 14.3 447 152 31.4 0.46 13 3.00 13.7 425 145 36.4 0.41 11 3.21 14.7 462 161 33.6 0.39 12 3.12 14.3 448 156 37.5 0.43 11 3.24 14.8 466 162 - 28.2 0.95 20 3.04 14.2 430 134 26.0 0.91 21 2.96 13.8 417 130 29.0 0.99 20 3.06 14.3 435 136 25.6 0.80 18 2.94 13.7 413 129 29.0 0.85 19 3.11 14.5 463 143 26.8 0.82 19 3.03 14.1 449 139 29.9 0.89 18 3.13 14.6 468 144 26.5 0.67 16 3.00 14.0 445 137 63 29.6 0.73 15 3.11 14.5 463 143 28.7 0.70 15 3.08 14.4 458 142 31.4 0.64 15 3.21 14.9 489 156 29.0 0.62 16 3.13 14.6 474 151 32.4 0.67 15 3.24 15.1 494 158 29.1 0.47 12 3.10 14.4 470 150 67 32.4 0.51 11 3.21 14.9 489 156 31.5 0.48 12 3.18 14.8 484 155 115 33.7 0.41 11 3.32 15.4 510 166 31.1 0.40 11 3.24 15.0 495 161 34.7 0.43 10 3.35 15.6 515 168 - 71 - COOLING OPERATION Design Subcooling, 10 ±2 °F @ the liquid access fitting connection ARI 95 test conditions. Design Superheat 9 ±2 °F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MBh 34.9 36.2 39.6 34.1 35.3 38.7 33.3 34.5 37.8 32.5 33.6 36.9 30.8 32.0 35.0 28.6 S/T 0.76 0.64 0.44 0.79 0.66 0.46 0.81 0.68 0.47 0.84 0.70 0.48 0.87 0.72 0.50 0.87 Delta T 18 16 12 18 16 12 18 16 12 18 16 12 18 16 12 17 1349 KW 2.33 2.38 2.45 2.51 2.57 2.65 2.67 2.73 2.82 2.81 2.88 2.97 2.93 3.00 3.10 3.04 AMPS 10.5 10.8 11.0 11.3 11.5 11.8 12.1 12.3 12.7 12.8 13.1 13.4 13.5 13.8 14.2 14.2 HI PR 238 256 271 267 288 304 304 327 345 346 372 393 389 419 442 430 LO PR 107 114 125 114 121 132 118 126 137 124 132 144 130 138 151 134 MBh 33.9 35.1 38.5 33.1 34.3 37.6 32.3 33.5 36.7 31.5 32.7 35.8 29.9 31.0 34.0 27.7 S/T 0.73 0.61 0.42 0.75 0.63 0.44 0.77 0.64 0.45 0.80 0.67 0.46 0.83 0.69 0.48 0.83 Delta T 19 16 12 19 17 13 19 17 13 19 17 13 19 16 12 18 70 1200 KW 2.31 2.36 2.43 2.49 2.54 2.63 2.65 2.71 2.80 2.79 2.85 2.95 2.91 2.97 3.07 3.01 AMPS 10.5 10.7 11.0 11.2 11.4 11.7 12.0 12.2 12.6 12.7 12.9 13.3 13.4 13.7 14.1 14.1 HI PR 236 254 268 265 285 301 301 324 342 343 369 389 386 415 438 426 LO PR 106 113 124 112 120 131 117 124 136 123 131 143 129 137 149 133 MODEL: GPC1436H41A* COOLING PERFORMANCE DATA GPC1436H41A* 17 18 EXPANDED PERFORMANCE DATA 85 80 32.4 0.87 25 2.29 10.4 233 105 36.7 1.00 25 2.39 10.8 245 111 35.7 0.95 26 2.37 10.7 243 110 32.9 0.92 26 2.31 10.5 236 106 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1200 1052 1349 1200 1052 33.6 0.88 26 2.36 10.7 254 113 36.4 0.92 26 2.42 10.9 261 117 37.4 0.96 25 2.44 11.0 264 118 33.1 0.82 24 2.34 10.6 251 112 35.8 0.85 23 2.40 10.8 259 116 35.1 0.80 24 2.43 11.0 268 124 38.1 0.83 24 2.50 11.2 276 127 39.2 0.87 23 2.52 11.3 279 129 35.3 0.67 21 2.41 10.9 265 122 38.3 0.69 20 2.48 11.1 273 126 37.5 0.65 21 2.51 11.3 279 132 40.6 0.67 21 2.58 11.6 288 136 41.8 0.70 20 2.60 11.7 291 137 37.8 0.50 16 2.49 11.2 277 130 40.9 0.52 16 2.56 11.5 285 134 32.2 0.95 27 2.49 11.2 264 112 34.8 0.98 26 2.55 11.4 273 116 35.9 1.00 24 2.57 11.5 275 117 31.6 0.90 25 2.47 11.1 262 111 34.2 0.94 25 2.53 11.3 270 115 32.8 0.92 26 2.54 11.4 285 120 35.5 0.95 26 2.61 11.7 293 123 36.6 1.00 25 2.63 11.8 296 124 32.3 0.85 24 2.52 11.3 282 118 35.0 0.88 24 2.59 11.6 290 122 34.3 0.83 25 2.63 11.7 301 131 37.2 0.86 24 2.69 12.0 310 135 38.3 0.90 23 2.72 12.1 313 136 34.5 0.69 21 2.60 11.6 298 129 37.4 0.72 21 2.67 11.9 307 133 36.6 0.67 21 2.71 12.1 313 139 39.7 0.70 21 2.78 12.4 323 143 40.9 0.73 20 2.81 12.5 326 145 36.9 0.52 17 2.69 12.0 310 138 40.0 0.54 16 2.76 12.3 320 142 31.4 0.97 27 2.65 12.0 301 117 34.0 1.00 26 2.72 12.3 310 120 35.0 1.00 24 2.74 12.4 313 122 30.9 0.93 25 2.63 11.9 298 116 33.4 0.96 25 2.69 12.2 307 119 32.0 0.94 26 2.71 12.2 324 124 34.7 0.97 26 2.78 12.5 334 128 35.7 1.00 24 2.80 12.6 337 129 31.5 0.87 24 2.68 12.1 320 123 NOTE: 34.2 0.90 24 2.75 12.4 330 127 39.0 0.55 16 2.94 13.2 364 147 32.6 0.99 25 2.84 12.9 350 125 33.3 0.93 24 2.90 13.2 376 133 35.6 0.76 21 3.00 13.5 397 145 38.1 0.57 17 3.10 14.0 414 155 33.5 0.85 25 2.80 12.6 342 136 36.3 0.88 24 2.87 12.9 352 140 37.4 0.92 23 2.89 13.0 356 141 35.8 0.69 21 2.89 13.0 356 144 38.7 0.71 21 2.97 13.3 368 149 39.9 0.75 20 2.99 13.4 371 150 30.6 1.00 27 2.79 12.7 343 123 33.2 1.00 25 2.86 13.0 353 126 34.2 1.00 23 2.89 13.1 357 128 31.2 0.97 26 2.85 12.9 369 131 33.8 1.00 26 2.93 13.3 380 135 34.8 1.00 24 2.95 13.4 384 136 32.7 0.87 25 2.95 13.3 389 142 35.4 0.91 25 3.02 13.6 401 147 36.5 0.95 24 3.05 13.8 405 148 34.9 0.71 22 3.05 13.8 406 152 37.8 0.74 21 3.13 14.1 419 156 38.9 0.77 20 3.15 14.2 423 158 33.7 36.0 30.1 30.8 32.9 35.1 0.71 0.53 0.96 0.90 0.73 0.55 21 17 25 24 21 17 2.77 2.87 2.77 2.83 2.92 3.02 12.5 12.9 12.6 12.8 13.2 13.6 338 353 339 365 385 402 134 143 121 129 141 150 Shaded area reflects AHRI rating conditions 36.5 0.73 21 2.84 12.8 349 138 29.1 1.00 25 2.91 13.4 385 129 31.5 1.00 24 2.98 13.7 397 133 32.5 1.00 22 3.01 13.8 401 134 28.6 0.99 25 2.88 13.3 382 127 31.0 1.00 24 2.96 13.6 393 131 29.7 1.00 26 2.97 13.7 415 137 32.1 1.00 25 3.05 14.0 428 141 33.1 1.00 23 3.08 14.1 432 142 29.2 0.93 24 2.95 13.6 411 135 31.7 0.97 23 3.03 13.9 423 140 31.1 0.91 25 3.07 14.1 438 149 33.7 0.94 24 3.15 14.4 451 154 34.7 0.99 23 3.18 14.5 456 155 31.2 0.76 21 3.05 14.0 434 148 33.8 0.79 20 3.13 14.3 447 152 * NOTE: Shaded areas is AHRI Rating Conditions IDB: Entering Indoor Dry Bulb Temperature KW = Total system power High and low pressures are measured at the liquid and suction access fittings. AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 35.1 0.91 24 2.35 10.6 241 109 MBh S/T Delta T KW AMPS HI PR LO PR 33.1 0.74 21 3.18 14.5 457 159 35.9 0.76 21 3.26 14.9 471 164 37.0 0.80 20 3.29 15.0 476 166 33.4 0.57 17 3.15 14.4 452 157 36.2 0.59 16 3.24 14.8 466 162 26.9 1.00 24 3.01 14.1 426 133 29.2 1.00 22 3.09 14.4 439 137 30.1 1.00 21 3.12 14.5 443 138 26.5 1.00 23 2.99 14.0 422 132 28.7 1.00 22 3.06 14.3 435 136 27.5 1.00 24 3.08 14.4 458 141 29.8 1.00 23 3.16 14.7 472 146 30.7 1.00 21 3.19 14.9 477 147 27.1 0.94 22 3.05 14.3 454 140 29.3 0.97 22 3.13 14.6 468 144 63 30.2 1.00 21 3.16 14.7 472 146 28.8 0.92 23 3.18 14.8 484 154 31.2 0.95 23 3.27 15.2 499 159 32.1 1.00 22 3.30 15.3 504 161 28.9 0.77 19 3.16 14.7 479 153 31.3 0.79 19 3.24 15.1 494 158 67 32.3 0.83 18 3.27 15.2 499 159 115 30.7 0.74 20 3.29 15.3 505 165 33.3 0.77 20 3.38 15.7 520 170 34.3 0.81 19 3.41 15.8 525 171 30.9 0.57 15 3.26 15.2 500 163 33.5 0.59 15 3.35 15.6 515 168 71 34.5 0.62 15 3.38 15.7 520 170 COOLING OPERATION Design Subcooling, 10 ±2 °F @ the liquid access fitting connection ARI 95 test conditions. Design Superheat 9 ±2 °F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MBh 36.1 36.9 39.4 42.1 35.3 36.0 38.5 41.2 34.4 35.2 37.6 40.2 33.6 34.3 36.7 39.2 31.9 32.6 34.8 37.2 29.6 S/T 0.95 0.89 0.72 0.54 1.00 0.92 0.75 0.56 1.00 0.95 0.77 0.58 1.00 1.00 0.80 0.59 1.00 1.00 0.83 0.62 1.00 Delta T 23 22 19 16 24 23 20 16 23 23 20 16 23 23 20 16 22 22 20 16 20 1349 KW 2.37 2.42 2.50 2.58 2.55 2.61 2.69 2.78 2.72 2.78 2.87 2.97 2.86 2.93 3.02 3.13 2.98 3.05 3.15 3.26 3.09 AMPS 10.7 10.9 11.2 11.6 11.4 11.7 12.0 12.4 12.3 12.5 12.9 13.3 13.0 13.3 13.6 14.1 13.7 14.0 14.4 14.9 14.4 HI PR 243 261 276 288 273 293 310 323 310 334 352 368 353 380 401 419 397 428 451 471 439 LO PR 110 117 127 136 116 123 135 143 120 128 140 149 126 135 147 156 133 141 154 164 137 MODEL: GPC1436H41A* COOLING PERFORMANCE DATA GPC1436H41A* EXPANDED PERFORMANCE DATA 39.2 0.81 23 2.54 11.6 236 110 36.2 0.79 23 2.48 11.3 229 106 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1461 1139 1300 40.4 0.85 22 2.56 11.7 238 111 MBh S/T Delta T KW AMPS HI PR LO PR 1139 40.3 0.73 21 2.60 11.8 254 117 37.2 0.70 21 2.53 11.5 246 113 41.6 0.76 20 2.62 11.9 257 118 36.9 0.58 17 2.51 11.4 244 112 43.7 0.55 17 2.68 12.1 268 127 40.3 0.53 17 2.62 11.9 260 123 45.0 0.58 16 2.70 12.2 271 128 40.4 0.40 13 2.59 11.8 258 122 46.9 0.35 12 2.77 12.5 280 135 43.3 0.34 12 2.70 12.2 271 131 48.3 0.37 11 2.79 12.6 283 137 - 38.3 0.84 23 2.74 12.4 265 116 35.3 0.81 23 2.67 12.1 257 112 39.4 0.88 22 2.77 12.5 268 117 34.7 0.72 20 2.65 12.0 254 111 39.4 0.75 21 2.80 12.6 285 123 36.4 0.73 21 2.73 12.3 277 119 40.6 0.79 20 2.83 12.7 288 124 36.0 0.60 17 2.71 12.2 274 118 * IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction access fittings. 75 35.6 0.69 20 2.46 11.2 227 105 MBh S/T Delta T KW AMPS HI PR LO PR 45.8 0.37 12 2.99 13.4 314 143 42.3 0.35 12 2.92 13.1 305 139 47.2 0.39 11 3.02 13.5 317 145 - 37.4 0.87 23 2.92 13.3 301 120 34.5 0.83 23 2.85 13.0 292 117 38.5 0.91 22 2.94 13.4 304 121 33.9 0.73 20 2.82 12.9 289 115 38.5 0.77 21 2.98 13.6 324 128 35.5 0.75 21 2.91 13.3 314 124 39.6 0.81 20 3.01 13.7 327 129 35.1 0.61 17 2.88 13.2 311 123 41.6 0.59 17 3.08 14.0 342 140 38.4 0.56 18 3.00 13.7 332 135 42.9 0.61 17 3.11 14.1 346 141 38.5 0.42 13 2.98 13.5 329 134 44.7 0.38 12 3.19 14.5 357 149 41.2 0.36 12 3.11 14.1 346 144 46.0 0.40 11 3.21 14.6 361 150 - 36.5 0.89 23 3.07 14.1 343 126 33.6 0.86 23 3.00 13.8 333 123 37.5 0.94 22 3.10 14.2 347 128 33.1 0.76 20 2.97 13.7 329 121 NOTE: Shaded area is ACCA (TVA) conditions 42.7 0.57 17 2.89 13.0 301 134 39.4 0.55 18 2.82 12.7 292 130 43.9 0.60 17 2.92 13.1 304 136 39.4 0.41 13 2.80 12.6 289 129 40.6 0.60 17 3.25 14.9 390 147 37.5 0.58 18 3.17 14.5 378 142 41.8 0.63 17 3.28 15.0 394 148 38.7 0.84 20 3.17 14.5 373 136 37.5 0.80 21 3.14 14.4 369 134 34.6 0.77 22 3.06 14.1 358 130 37.6 0.44 13 3.14 14.4 374 141 34.3 0.63 18 3.04 14.0 355 129 43.6 0.39 12 3.36 15.4 407 156 40.2 0.38 12 3.27 15.0 394 152 44.9 0.41 12 3.39 15.5 411 158 - 34.6 0.93 23 3.21 14.9 386 132 32.0 0.89 23 3.13 14.6 374 128 35.7 0.97 22 3.23 15.1 390 134 31.4 0.79 20 3.10 14.4 371 127 35.7 0.83 21 3.28 15.3 415 141 32.9 0.80 21 3.20 14.9 403 137 36.7 0.87 20 3.31 15.4 420 142 32.6 0.66 17 3.17 14.8 399 135 38.6 0.63 17 3.39 15.7 439 154 35.6 0.61 17 3.30 15.3 425 149 39.7 0.66 16 3.42 15.8 443 155 35.7 0.46 13 3.27 15.2 421 148 41.4 0.40 12 3.51 16.3 458 164 38.2 0.39 12 3.42 15.8 444 159 42.7 0.42 11 3.54 16.4 462 165 - 32.1 0.93 21 3.32 15.7 427 137 29.6 0.90 22 3.24 15.3 414 133 33.0 0.98 20 3.35 15.9 431 138 29.1 0.79 19 3.21 15.2 410 131 33.0 0.84 20 3.40 16.1 459 146 30.5 0.81 20 3.31 15.7 445 141 34.0 0.88 19 3.43 16.2 464 147 30.2 0.66 16 3.28 15.5 441 140 63 33.7 0.72 15 3.40 16.1 459 146 32.7 0.69 16 3.37 15.9 454 144 35.7 0.63 16 3.51 16.6 485 159 33.0 0.61 16 3.42 16.1 470 154 36.8 0.66 15 3.54 16.7 490 161 33.1 0.46 12 3.39 16.0 465 153 67 36.9 0.50 12 3.51 16.6 485 159 35.8 0.48 12 3.48 16.4 480 157 115 38.4 0.41 11 3.63 17.1 506 169 35.4 0.39 11 3.54 16.7 490 164 39.5 0.43 11 3.66 17.3 511 171 - 71 - COOLING OPERATION Design Subcooling, 8 ± 2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 8 ± 2 °F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MBh 39.7 41.1 45.1 38.8 40.2 44.0 37.8 39.2 43.0 36.9 38.3 41.9 35.1 36.4 39.8 32.5 S/T 0.75 0.63 0.43 0.78 0.65 0.45 0.80 0.67 0.46 0.82 0.69 0.48 0.86 0.71 0.49 0.86 Delta T 19 16 12 19 16 12 19 16 12 19 17 13 19 16 12 18 1461 KW 2.54 2.60 2.68 2.74 2.80 2.89 2.92 2.98 3.08 3.07 3.14 3.25 3.21 3.28 3.39 3.32 AMPS 11.6 11.8 12.1 12.4 12.6 13.0 13.3 13.6 14.0 14.1 14.4 14.9 14.9 15.3 15.7 15.7 HI PR 236 254 268 265 285 301 301 324 342 343 369 390 386 415 439 426 LO PR 110 116 127 116 123 134 120 128 140 126 134 147 132 141 154 137 MBh 38.5 39.9 43.8 37.6 39.0 42.7 36.7 38.1 41.7 35.8 37.1 40.7 34.1 35.3 38.7 31.5 S/T 0.72 0.60 0.41 0.74 0.62 0.43 0.76 0.64 0.44 0.79 0.66 0.45 0.82 0.68 0.47 0.82 Delta T 20 17 13 20 17 13 20 17 13 20 17 13 20 17 13 18 70 1300 KW 2.52 2.58 2.66 2.72 2.78 2.87 2.89 2.96 3.06 3.05 3.12 3.22 3.18 3.25 3.36 3.29 AMPS 11.5 11.7 12.0 12.3 12.5 12.9 13.2 13.5 13.9 14.0 14.3 14.7 14.8 15.1 15.6 15.6 HI PR 234 251 266 262 282 298 298 321 339 340 366 386 382 411 434 422 LO PR 108 115 126 115 122 133 119 127 138 125 133 145 131 139 152 136 MODEL: GPC1442H41A* COOLING PERFORMANCE DATA GPC1442H41A* 19 20 EXPANDED PERFORMANCE DATA 85 80 36.8 0.86 26 2.50 11.4 231 107 41.8 0.98 26 2.61 11.8 243 113 40.6 0.94 27 2.58 11.8 241 112 37.5 0.90 27 2.52 11.5 234 108 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1300 1139 1461 1300 1139 38.2 0.87 27 2.58 11.7 251 115 41.4 0.90 26 2.64 12.0 259 119 42.6 0.95 25 2.66 12.1 262 120 37.6 0.81 25 2.56 11.6 249 114 40.8 0.84 24 2.62 11.9 257 118 40.0 0.79 25 2.66 12.0 265 126 43.3 0.82 25 2.73 12.3 274 130 44.6 0.85 24 2.75 12.4 276 131 40.2 0.66 21 2.64 12.0 263 125 43.5 0.68 21 2.70 12.2 271 128 42.7 0.64 22 2.75 12.4 277 134 46.2 0.66 22 2.82 12.7 285 138 47.6 0.69 21 2.84 12.8 288 140 43.0 0.49 17 2.72 12.3 274 133 46.5 0.51 17 2.79 12.6 283 137 36.6 0.94 28 2.72 12.3 262 115 39.6 0.97 27 2.79 12.6 270 118 40.8 1.00 26 2.81 12.7 273 119 36.0 0.89 26 2.70 12.2 260 113 39.0 0.93 25 2.77 12.5 268 117 37.3 0.90 27 2.78 12.5 282 122 40.4 0.94 27 2.85 12.8 291 126 41.6 0.98 26 2.87 12.9 294 127 36.7 0.84 25 2.76 12.4 279 121 39.8 0.87 24 2.83 12.7 288 124 39.1 0.81 26 2.87 12.9 298 133 42.3 0.85 25 2.94 13.2 307 137 43.6 0.89 24 2.97 13.3 310 138 39.3 0.68 22 2.85 12.8 295 132 42.5 0.71 21 2.92 13.1 304 136 41.7 0.66 22 2.97 13.3 311 142 45.1 0.69 22 3.04 13.6 320 146 46.5 0.72 21 3.07 13.8 324 147 42.0 0.51 17 2.94 13.2 308 140 45.5 0.53 17 3.02 13.5 317 145 35.7 0.96 28 2.89 13.2 298 119 38.7 1.00 27 2.97 13.5 307 123 39.9 1.00 25 2.99 13.6 310 124 35.1 0.92 26 2.87 13.1 295 118 38.0 0.95 26 2.94 13.4 304 121 36.4 0.93 27 2.96 13.5 321 127 39.4 0.96 27 3.03 13.8 331 131 40.6 1.00 26 3.06 13.9 334 132 35.9 0.86 25 2.93 13.4 318 125 NOTE: 38.9 0.89 24 3.01 13.7 327 129 44.4 0.54 17 3.21 14.6 361 150 37.1 0.98 26 3.10 14.2 347 128 37.9 0.92 25 3.17 14.5 373 136 40.5 0.75 21 3.28 15.0 394 148 43.3 0.56 17 3.39 15.5 411 158 38.1 0.84 26 3.06 13.9 339 138 41.3 0.87 25 3.14 14.2 349 142 42.5 0.91 24 3.16 14.3 353 144 40.7 0.68 22 3.16 14.3 353 147 44.1 0.70 22 3.24 14.7 364 152 45.4 0.74 21 3.27 14.8 368 153 34.8 0.99 28 3.05 14.0 340 125 37.7 1.00 27 3.13 14.4 350 129 38.9 1.00 24 3.15 14.5 354 130 35.5 0.96 27 3.12 14.3 365 133 38.5 0.99 27 3.20 14.7 377 137 39.6 1.00 25 3.22 14.8 380 138 37.2 0.86 26 3.22 14.7 386 145 40.3 0.89 25 3.30 15.1 398 150 41.5 0.94 24 3.33 15.2 402 151 39.7 0.70 22 3.33 15.2 402 155 43.0 0.73 22 3.42 15.6 415 159 44.3 0.76 21 3.45 15.7 419 161 38.3 41.0 34.2 35.0 37.4 40.0 0.70 0.52 0.94 0.89 0.72 0.54 22 17 26 25 22 17 3.03 3.13 3.02 3.09 3.19 3.30 13.8 14.2 13.9 14.2 14.6 15.1 335 350 336 362 382 398 137 146 124 132 144 153 Shaded area reflects AHRI rating conditions 41.5 0.72 21 3.11 14.1 346 141 33.1 1.00 27 3.18 14.8 382 131 35.9 1.00 25 3.26 15.2 394 135 36.9 1.00 23 3.29 15.3 398 136 32.5 0.98 26 3.15 14.7 378 130 35.2 1.00 25 3.23 15.1 390 134 33.7 0.99 27 3.25 15.1 411 139 36.6 1.00 26 3.34 15.5 424 144 37.6 1.00 24 3.36 15.6 428 145 33.2 0.92 25 3.22 15.0 407 138 36.0 0.95 24 3.31 15.4 420 142 35.3 0.90 26 3.36 15.6 434 152 38.3 0.93 25 3.45 16.0 448 157 39.4 0.97 24 3.48 16.1 452 158 35.5 0.75 21 3.33 15.4 430 151 38.5 0.78 21 3.42 15.8 443 155 * NOTE: Shaded areas is AHRI Rating Conditions IDB: Entering Indoor Dry Bulb Temperature KW = Total system power High and low pressures are measured at the liquid and suction access fittings. AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 39.9 0.89 25 2.56 11.7 238 111 MBh S/T Delta T KW AMPS HI PR LO PR 37.7 0.73 22 3.48 16.1 453 162 40.8 0.75 22 3.57 16.5 467 167 42.1 0.79 21 3.60 16.7 471 169 38.0 0.56 17 3.45 16.0 448 160 41.1 0.58 17 3.54 16.4 462 165 30.7 1.00 25 3.29 15.6 422 136 33.2 1.00 23 3.38 16.0 435 140 34.2 1.00 22 3.41 16.1 439 141 30.1 0.99 24 3.26 15.5 418 134 32.6 1.00 23 3.35 15.9 431 138 31.3 1.00 25 3.37 15.9 454 144 33.9 1.00 24 3.46 16.3 468 149 34.9 1.00 22 3.49 16.5 473 150 30.8 0.93 23 3.34 15.8 450 143 33.4 0.96 23 3.43 16.2 464 147 63 34.4 1.00 22 3.46 16.3 468 149 32.7 0.90 24 3.48 16.4 480 157 35.5 0.94 23 3.57 16.8 494 162 36.5 0.98 23 3.60 17.0 499 164 32.9 0.75 20 3.45 16.3 475 156 35.6 0.78 20 3.54 16.7 490 161 67 36.7 0.82 19 3.57 16.8 494 162 115 34.9 0.73 21 3.60 17.0 500 168 37.8 0.76 20 3.70 17.4 516 173 39.0 0.80 20 3.73 17.6 521 175 35.2 0.56 16 3.57 16.8 495 166 38.1 0.59 16 3.67 17.3 511 171 71 39.2 0.61 15 3.70 17.4 516 173 COOLING OPERATION Design Subcooling, 8 ± 2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 8 ± 2 °F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MBh 41.1 42.0 44.8 47.9 40.1 41.0 43.8 46.8 39.2 40.0 42.8 45.7 38.2 39.0 41.7 44.6 36.3 37.1 39.6 42.4 33.6 S/T 0.94 0.88 0.71 0.53 0.97 0.91 0.74 0.55 1.00 0.93 0.76 0.57 1.00 0.96 0.78 0.59 1.00 1.00 0.81 0.61 1.00 Delta T 24 23 20 16 25 23 20 16 25 24 20 16 24 24 21 16 23 23 20 16 21 1461 KW 2.58 2.64 2.73 2.82 2.79 2.85 2.94 3.04 2.97 3.03 3.14 3.24 3.13 3.20 3.30 3.42 3.26 3.34 3.45 3.57 3.38 AMPS 11.8 12.0 12.3 12.7 12.6 12.8 13.2 13.6 13.5 13.8 14.2 14.7 14.4 14.7 15.1 15.6 15.2 15.5 16.0 16.5 16.0 HI PR 241 259 274 285 270 291 307 320 307 331 349 364 350 377 398 415 394 424 448 467 435 LO PR 112 119 130 138 118 126 137 146 123 131 142 152 129 137 150 159 135 144 157 167 140 MODEL: GPC1442H41A* COOLING PERFORMANCE DATA GPC1442H41A* EXPANDED PERFORMANCE DATA 45.0 0.83 21 2.94 12.7 236 110 41.5 0.80 22 2.87 12.4 229 107 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1800 1400 1600 46.3 0.87 21 2.97 12.8 238 112 MBh S/T Delta T KW AMPS HI PR LO PR 1400 46.3 0.74 20 3.01 13.0 254 118 42.8 0.71 20 2.93 12.7 246 114 47.7 0.78 19 3.03 13.1 256 119 42.3 0.59 16 2.91 12.6 243 113 50.1 0.56 16 3.10 13.4 268 128 46.3 0.54 16 3.03 13.1 260 124 51.6 0.59 15 3.13 13.5 270 130 46.4 0.41 12 3.00 13.0 257 123 53.8 0.36 11 3.20 13.8 279 137 49.7 0.35 11 3.12 13.5 271 133 55.4 0.38 11 3.23 14.0 282 138 - 43.9 0.86 22 3.17 13.7 264 117 40.6 0.83 22 3.09 13.3 256 113 45.3 0.90 21 3.20 13.8 267 118 39.9 0.73 19 3.07 13.2 254 112 45.2 0.77 20 3.24 14.0 285 124 41.8 0.74 20 3.16 13.6 276 120 46.6 0.80 19 3.27 14.1 287 125 41.3 0.61 16 3.13 13.5 273 119 * IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction access fittings. 75 40.8 0.70 19 2.85 12.3 226 106 MBh S/T Delta T KW AMPS HI PR LO PR 52.6 0.37 11 3.45 14.9 313 144 48.5 0.36 11 3.37 14.5 304 140 54.1 0.39 11 3.48 15.0 317 146 - 42.9 0.88 22 3.37 14.7 301 121 39.6 0.85 22 3.29 14.4 292 118 44.2 0.92 21 3.40 14.8 304 122 38.9 0.75 19 3.26 14.2 289 116 44.2 0.79 20 3.44 15.0 324 129 40.8 0.76 20 3.36 14.7 314 125 45.5 0.82 19 3.47 15.2 327 130 40.4 0.62 16 3.33 14.5 311 124 47.8 0.59 16 3.56 15.5 342 141 44.1 0.57 17 3.47 15.1 331 137 49.2 0.62 16 3.59 15.6 345 142 44.2 0.43 13 3.44 15.0 328 135 51.3 0.38 11 3.68 16.0 356 150 47.4 0.37 11 3.58 15.6 346 146 52.8 0.40 11 3.71 16.2 360 152 - 41.9 0.91 22 3.55 15.6 343 127 38.6 0.87 22 3.46 15.2 332 124 43.1 0.95 21 3.58 15.8 346 129 38.0 0.77 19 3.43 15.1 329 122 NOTE: Shaded area is ACCA (TVA) conditions 49.0 0.58 16 3.34 14.4 300 136 45.2 0.56 17 3.26 14.0 291 131 50.4 0.61 16 3.37 14.5 303 137 45.3 0.42 13 3.23 13.9 289 130 46.6 0.61 16 3.75 16.5 389 148 43.0 0.59 17 3.65 16.1 378 144 48.0 0.64 16 3.78 16.6 393 149 44.4 0.85 19 3.66 16.1 372 137 43.1 0.81 20 3.63 16.0 369 136 39.8 0.78 20 3.54 15.6 358 131 43.1 0.45 13 3.62 15.9 374 142 39.4 0.64 17 3.51 15.5 354 130 50.1 0.40 11 3.87 17.0 406 158 46.2 0.38 12 3.77 16.6 394 153 51.6 0.41 11 3.90 17.2 410 159 - 39.8 0.94 22 3.70 16.6 385 134 36.7 0.91 22 3.61 16.1 374 129 41.0 0.99 21 3.73 16.7 389 135 36.1 0.80 19 3.57 16.0 370 128 40.9 0.84 20 3.78 16.9 415 142 37.8 0.81 20 3.69 16.5 402 138 42.2 0.88 19 3.81 17.1 419 143 37.4 0.67 16 3.65 16.4 398 136 44.3 0.64 16 3.91 17.4 438 155 40.9 0.61 17 3.81 17.0 425 150 45.6 0.67 16 3.94 17.6 442 157 41.0 0.46 12 3.78 16.9 420 149 47.6 0.41 11 4.04 18.1 457 165 43.9 0.40 11 3.94 17.6 443 160 49.0 0.43 11 4.07 18.2 461 167 - 36.8 0.95 20 3.83 17.5 426 138 34.0 0.92 20 3.73 17.0 413 134 37.9 1.00 19 3.86 17.6 430 139 33.4 0.81 18 3.70 16.9 409 133 37.9 0.85 18 3.91 17.9 458 147 35.0 0.82 19 3.81 17.4 444 143 39.1 0.89 18 3.95 18.0 463 148 34.6 0.67 15 3.78 17.2 440 141 63 38.7 0.73 14 3.91 17.9 458 147 37.5 0.70 15 3.88 17.7 454 145 41.0 0.64 15 4.05 18.4 484 160 37.9 0.62 15 3.94 17.9 469 156 42.3 0.67 15 4.08 18.6 489 162 38.0 0.47 12 3.91 17.8 465 154 67 42.4 0.51 11 4.04 18.4 484 160 41.1 0.48 11 4.01 18.2 479 159 115 44.0 0.41 10 4.18 19.1 505 171 40.7 0.40 11 4.08 18.6 489 166 45.4 0.43 10 4.22 19.2 510 173 - 71 - COOLING OPERATION Design Subcooling, 10 ± 2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 10 ± 2°F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MBh 45.6 47.2 51.7 44.5 46.1 50.5 43.4 45.0 49.3 42.4 43.9 48.1 40.3 41.7 45.7 37.3 S/T 0.76 0.64 0.44 0.79 0.66 0.46 0.81 0.68 0.47 0.84 0.70 0.48 0.87 0.73 0.50 0.88 Delta T 18 15 12 18 16 12 18 16 12 18 16 12 18 15 12 17 1800 KW 2.94 3.01 3.10 3.17 3.24 3.34 3.37 3.44 3.56 3.55 3.63 3.75 3.70 3.78 3.91 3.83 AMPS 12.7 13.0 13.4 13.7 14.0 14.4 14.7 15.0 15.5 15.6 16.0 16.5 16.6 16.9 17.4 17.5 HI PR 236 254 268 264 284 300 301 324 342 342 369 389 385 415 438 426 LO PR 110 117 128 117 124 135 121 129 141 127 135 148 133 142 155 138 MBh 44.2 45.9 50.2 43.2 44.8 49.1 42.2 43.7 47.9 41.2 42.7 46.7 39.1 40.5 44.4 36.2 S/T 0.73 0.61 0.42 0.75 0.63 0.44 0.77 0.65 0.45 0.80 0.67 0.46 0.83 0.69 0.48 0.84 Delta T 18 16 12 19 16 12 19 16 12 19 16 12 19 16 12 17 70 1600 KW 2.92 2.98 3.08 3.14 3.21 3.32 3.34 3.42 3.53 3.52 3.60 3.71 3.67 3.75 3.87 3.80 AMPS 12.6 12.9 13.3 13.6 13.8 14.3 14.6 14.9 15.4 15.5 15.9 16.3 16.4 16.8 17.3 17.3 HI PR 233 251 265 262 282 297 298 320 338 339 365 385 381 410 433 421 LO PR 109 116 127 116 123 134 120 128 139 126 134 146 132 141 153 137 MODEL: GPC1448H41A* COOLING PERFORMANCE DATA GPC1448H41A* 21 22 EXPANDED PERFORMANCE DATA 85 80 42.3 0.87 24 2.90 12.5 231 108 48.0 1.00 24 3.01 13.1 243 114 46.6 0.95 25 2.99 13.0 240 113 43.0 0.92 26 2.92 12.6 233 109 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1600 1400 1800 1600 1400 43.8 0.88 25 2.98 12.9 251 116 47.5 0.92 25 3.05 13.2 259 120 48.9 0.96 24 3.08 13.3 261 121 43.2 0.82 23 2.96 12.8 248 115 46.8 0.85 23 3.03 13.1 256 119 45.9 0.80 24 3.07 13.3 265 127 49.7 0.83 24 3.15 13.6 273 131 51.2 0.87 23 3.18 13.7 276 132 46.1 0.67 20 3.05 13.2 262 126 50.0 0.69 20 3.13 13.5 270 130 49.0 0.65 21 3.17 13.7 276 135 53.1 0.67 20 3.25 14.1 285 139 54.7 0.70 20 3.28 14.2 288 141 49.3 0.50 16 3.15 13.6 274 134 53.4 0.52 16 3.23 14.0 282 138 42.0 0.95 26 3.14 13.5 262 115 45.5 0.99 26 3.22 13.9 270 119 46.9 1.00 24 3.25 14.0 272 120 41.3 0.91 25 3.12 13.4 259 114 44.7 0.94 24 3.20 13.8 267 118 42.8 0.92 26 3.21 13.8 282 123 46.4 0.95 25 3.29 14.2 290 127 47.8 1.00 24 3.32 14.3 293 128 42.2 0.85 24 3.19 13.7 279 122 45.7 0.88 23 3.27 14.1 287 125 44.8 0.83 24 3.31 14.2 297 134 48.6 0.86 24 3.40 14.6 307 138 50.0 0.90 23 3.43 14.7 310 140 45.1 0.69 20 3.29 14.1 294 133 48.8 0.72 20 3.37 14.5 304 137 47.8 0.67 21 3.42 14.7 310 143 51.8 0.70 21 3.51 15.1 320 147 53.4 0.73 20 3.54 15.2 323 149 48.2 0.52 16 3.40 14.6 307 141 52.2 0.54 16 3.48 15.0 317 146 41.0 0.97 26 3.34 14.6 298 120 44.4 1.00 26 3.43 15.0 307 124 45.8 1.00 23 3.46 15.1 310 125 40.3 0.93 25 3.31 14.5 295 119 43.7 0.96 24 3.40 14.8 304 122 41.8 0.94 26 3.42 14.9 320 128 45.3 0.97 25 3.50 15.3 330 132 46.6 1.00 24 3.53 15.4 333 133 41.2 0.87 24 3.39 14.8 317 126 NOTE: 44.6 0.90 23 3.47 15.2 327 130 51.0 0.55 16 3.71 16.2 360 152 42.6 0.99 24 3.58 15.8 346 129 43.5 0.93 23 3.66 16.1 372 137 46.5 0.76 20 3.78 16.6 393 149 49.7 0.57 16 3.91 17.2 410 159 43.8 0.85 24 3.53 15.4 338 139 47.4 0.88 24 3.62 15.8 349 144 48.8 0.92 23 3.65 15.9 352 145 46.7 0.69 21 3.64 15.9 353 148 50.6 0.71 21 3.74 16.3 364 153 52.1 0.75 20 3.77 16.4 367 155 40.0 1.00 26 3.52 15.5 339 126 43.3 1.00 25 3.61 15.9 349 130 44.6 1.00 23 3.64 16.0 353 131 40.8 0.97 26 3.60 15.8 365 134 44.2 1.00 25 3.69 16.3 376 138 45.5 1.00 23 3.72 16.4 380 140 42.7 0.88 25 3.71 16.3 385 146 46.3 0.91 24 3.81 16.8 397 151 47.7 0.95 23 3.84 16.9 401 152 45.6 0.71 21 3.84 16.9 402 156 49.4 0.74 21 3.94 17.3 414 161 50.8 0.77 20 3.97 17.5 418 162 44.0 47.0 39.3 40.2 42.9 45.9 0.71 0.53 0.96 0.90 0.73 0.55 20 16 25 24 21 16 3.50 3.61 3.49 3.57 3.68 3.81 15.2 15.8 15.4 15.7 16.2 16.8 335 349 336 361 381 398 138 147 125 133 145 154 Shaded area reflects AHRI rating conditions 47.7 0.74 20 3.59 15.6 345 142 38.0 1.00 25 3.67 16.4 381 132 41.2 1.00 24 3.76 16.8 393 136 42.4 1.00 22 3.79 17.0 397 138 37.3 1.00 24 3.64 16.3 378 131 40.5 1.00 23 3.73 16.7 389 135 38.7 1.00 25 3.75 16.8 410 141 42.0 1.00 24 3.85 17.2 423 145 43.2 1.00 22 3.88 17.4 427 146 38.2 0.93 23 3.72 16.6 406 139 41.3 0.97 23 3.81 17.1 419 143 40.6 0.91 24 3.87 17.3 433 153 44.0 0.94 24 3.97 17.7 447 158 45.3 0.99 23 4.01 17.9 451 160 40.8 0.76 20 3.84 17.1 429 152 44.2 0.79 20 3.94 17.6 442 157 * NOTE: Shaded areas is AHRI Rating Conditions IDB: Entering Indoor Dry Bulb Temperature KW = Total system power High and low pressures are measured at the liquid and suction access fittings. AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 45.8 0.91 24 2.97 12.9 238 112 MBh S/T Delta T KW AMPS HI PR LO PR 43.3 0.74 21 4.00 17.9 452 163 46.9 0.76 21 4.11 18.4 466 168 48.3 0.80 20 4.14 18.5 471 170 43.6 0.57 16 3.97 17.7 447 162 47.2 0.59 16 4.07 18.2 461 167 35.2 1.00 23 3.79 17.3 421 137 38.1 1.00 22 3.89 17.8 434 141 39.3 1.00 20 3.93 17.9 439 142 34.6 1.00 23 3.76 17.2 417 135 37.5 1.00 22 3.86 17.6 430 139 35.9 1.00 24 3.88 17.7 453 145 38.9 1.00 22 3.98 18.2 467 150 40.0 1.00 20 4.02 18.3 472 151 35.4 0.94 22 3.85 17.5 449 144 38.3 0.98 21 3.95 18.0 463 148 63 39.5 1.00 20 3.98 18.2 467 150 37.6 0.92 23 4.01 18.2 479 159 40.7 0.95 22 4.11 18.7 494 164 41.9 1.00 21 4.15 18.9 499 165 37.8 0.77 19 3.98 18.1 474 157 40.9 0.79 19 4.08 18.6 489 162 67 42.1 0.83 18 4.11 18.7 494 164 115 40.1 0.74 20 4.15 18.9 499 169 43.4 0.77 19 4.26 19.4 515 174 44.7 0.81 18 4.29 19.6 520 176 40.4 0.57 15 4.11 18.7 494 167 43.7 0.59 15 4.22 19.2 510 173 71 45.1 0.62 14 4.26 19.4 515 174 COOLING OPERATION Design Subcooling, 10 ± 2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 10 ± 2°F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MBh 47.2 48.2 51.5 55.0 46.1 47.1 50.3 53.8 45.0 46.0 49.1 52.5 43.9 44.8 47.9 51.2 41.7 42.6 45.5 48.6 38.6 S/T 0.95 0.89 0.73 0.54 1.00 0.92 0.75 0.56 1.00 0.95 0.77 0.58 1.00 1.00 0.80 0.60 1.00 1.00 0.83 0.62 1.00 Delta T 23 22 19 15 24 22 19 15 23 22 19 15 22 23 19 16 21 22 19 15 20 1800 KW 2.99 3.05 3.15 3.25 3.22 3.29 3.40 3.51 3.43 3.50 3.62 3.74 3.61 3.69 3.81 3.94 3.76 3.85 3.97 4.11 3.89 AMPS 13.0 13.2 13.6 14.1 13.9 14.2 14.6 15.1 15.0 15.3 15.8 16.3 15.9 16.3 16.8 17.3 16.8 17.2 17.7 18.4 17.8 HI PR 240 259 273 285 270 290 307 320 307 330 349 364 349 376 397 414 393 423 447 466 434 LO PR 113 120 131 139 119 127 138 147 124 132 144 153 130 138 151 161 136 145 158 168 141 MODEL: GPC1448H41A* COOLING PERFORMANCE DATA GPC1448H41A* EXPANDED PERFORMANCE DATA 55.6 0.77 25 3.70 15.7 238 108 51.3 0.75 25 3.61 15.3 231 105 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1800 1400 1600 57.3 0.81 24 3.73 15.8 241 109 MBh S/T Delta T KW AMPS HI PR LO PR 1400 57.3 0.69 23 3.79 16.0 256 115 52.9 0.67 23 3.69 15.6 249 111 59.0 0.73 22 3.82 16.2 259 116 52.3 0.55 19 3.66 15.5 246 110 62.0 0.52 19 3.91 16.5 271 125 57.2 0.51 19 3.81 16.1 263 121 63.9 0.55 18 3.94 16.7 273 126 57.3 0.38 14 3.78 16.0 260 120 66.5 0.34 13 4.04 17.1 282 133 61.4 0.33 13 3.94 16.7 274 129 68.5 0.35 12 4.07 17.2 285 135 - 54.3 0.80 25 4.00 16.9 267 114 50.2 0.77 25 3.90 16.4 259 110 56.0 0.84 24 4.03 17.0 270 115 49.3 0.68 22 3.87 16.3 257 109 55.9 0.72 23 4.09 17.3 288 121 51.6 0.69 23 3.99 16.8 279 118 57.6 0.75 22 4.12 17.4 291 122 51.1 0.57 19 3.95 16.7 276 116 * IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction access fittings. 75 50.5 0.66 22 3.58 15.2 229 103 MBh S/T Delta T KW AMPS HI PR LO PR 65.0 0.35 13 4.37 18.4 317 141 60.0 0.34 13 4.26 17.9 307 137 66.9 0.37 13 4.41 18.6 320 142 - 53.0 0.82 25 4.26 18.2 304 118 49.0 0.79 26 4.15 17.8 295 115 54.6 0.86 24 4.30 18.4 307 120 48.1 0.70 22 4.12 17.6 292 114 54.6 0.74 23 4.36 18.6 327 126 50.4 0.71 24 4.25 18.2 317 122 56.3 0.77 22 4.40 18.8 330 127 49.9 0.58 19 4.21 18.0 314 121 59.1 0.56 19 4.51 19.2 346 137 54.6 0.54 19 4.39 18.7 335 133 60.9 0.58 18 4.55 19.4 349 139 54.7 0.40 15 4.35 18.6 332 132 63.4 0.36 13 4.66 19.9 360 146 58.6 0.35 13 4.54 19.4 350 142 65.3 0.38 13 4.70 20.1 364 148 - 51.8 0.85 25 4.49 19.4 346 124 47.8 0.82 26 4.38 18.9 336 121 53.3 0.89 24 4.53 19.6 350 126 47.0 0.72 22 4.34 18.7 333 119 NOTE: Shaded area is ACCA (TVA) conditions 60.6 0.54 19 4.23 17.8 304 132 55.9 0.52 19 4.12 17.3 295 128 62.4 0.57 18 4.26 17.9 307 134 56.0 0.39 14 4.08 17.2 292 127 57.7 0.58 19 4.75 20.5 394 144 53.2 0.55 19 4.63 19.9 382 140 59.4 0.60 18 4.79 20.7 397 146 54.9 0.80 22 4.64 20.0 376 134 53.3 0.76 23 4.60 19.9 373 132 49.2 0.73 24 4.48 19.3 361 128 53.3 0.42 15 4.59 19.8 378 139 48.7 0.60 19 4.44 19.2 358 127 61.9 0.37 13 4.92 21.2 410 154 57.1 0.36 13 4.79 20.7 398 149 63.8 0.39 13 4.96 21.4 415 155 - 49.2 0.88 25 4.69 20.6 390 130 45.4 0.85 25 4.57 20.0 378 126 50.6 0.92 24 4.73 20.8 393 132 44.6 0.75 22 4.53 19.9 374 125 50.6 0.79 23 4.80 21.1 419 139 46.7 0.76 23 4.67 20.5 407 134 52.1 0.83 22 4.84 21.3 423 140 46.2 0.62 19 4.63 20.3 403 133 54.8 0.60 19 4.96 21.7 443 151 50.6 0.58 19 4.83 21.2 429 147 56.4 0.63 18 5.01 21.9 447 153 50.7 0.43 14 4.79 21.0 425 145 58.8 0.38 13 5.14 22.5 462 161 54.3 0.37 13 5.00 21.9 448 156 60.6 0.40 12 5.18 22.7 466 163 - 45.5 0.89 23 4.86 21.7 430 135 42.0 0.86 24 4.73 21.2 418 131 46.9 0.93 22 4.90 21.9 435 136 41.3 0.75 20 4.69 21.0 413 129 46.9 0.80 21 4.97 22.3 463 143 43.3 0.77 22 4.84 21.7 449 139 48.3 0.83 21 5.02 22.5 468 145 42.8 0.63 18 4.80 21.5 445 138 63 47.8 0.69 17 4.97 22.3 463 143 46.4 0.65 17 4.93 22.1 459 142 50.8 0.60 18 5.14 23.0 489 157 46.8 0.58 18 5.01 22.4 474 152 52.3 0.63 17 5.19 23.2 494 158 46.9 0.44 13 4.97 22.2 470 150 67 52.4 0.47 13 5.14 23.0 489 156 50.9 0.45 13 5.10 22.8 484 155 115 54.5 0.39 12 5.32 23.8 510 167 50.3 0.37 12 5.18 23.2 495 162 56.1 0.41 12 5.37 24.0 515 168 - 71 - COOLING OPERATION Design Subcooling, 6 ± 2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 9 ± 2°F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MBh 56.3 58.4 64.0 55.0 57.0 62.5 53.7 55.7 61.0 52.4 54.3 59.5 49.8 51.6 56.5 46.1 S/T 0.71 0.60 0.41 0.74 0.62 0.43 0.76 0.63 0.44 0.78 0.65 0.45 0.81 0.68 0.47 0.82 Delta T 21 18 14 21 18 14 21 18 14 21 18 14 21 18 14 19 1800 KW 3.70 3.78 3.91 4.00 4.09 4.23 4.26 4.36 4.51 4.49 4.60 4.75 4.69 4.80 4.96 4.86 AMPS 15.7 16.0 16.5 16.9 17.2 17.8 18.2 18.6 19.2 19.4 19.9 20.5 20.6 21.1 21.7 21.7 HI PR 238 256 271 267 288 304 304 327 345 346 373 393 390 419 443 430 LO PR 108 115 125 114 121 132 118 126 137 124 132 144 130 139 151 135 MBh 54.7 56.7 62.1 53.4 55.4 60.7 52.2 54.1 59.2 50.9 52.7 57.8 48.3 50.1 54.9 44.8 S/T 0.68 0.57 0.39 0.71 0.59 0.41 0.72 0.60 0.42 0.75 0.62 0.43 0.78 0.65 0.45 0.78 Delta T 21 19 14 22 19 14 22 19 14 22 19 14 22 19 14 20 70 1600 KW 3.67 3.75 3.88 3.97 4.06 4.19 4.23 4.32 4.47 4.46 4.56 4.71 4.65 4.76 4.92 4.82 AMPS 15.6 15.9 16.4 16.7 17.1 17.6 18.1 18.5 19.1 19.2 19.7 20.3 20.4 20.9 21.5 21.6 HI PR 236 254 268 265 285 301 301 324 342 343 369 390 386 415 438 426 LO PR 107 114 124 113 120 131 117 125 136 123 131 143 129 137 150 133 MODEL: GPC1460H41A* COOLING PERFORMANCE DATA GPC1460H41A* 23 24 EXPANDED PERFORMANCE DATA 85 80 52.3 0.82 28 3.64 15.4 233 106 59.3 0.93 28 3.80 16.1 245 111 57.6 0.89 29 3.77 16.0 243 110 53.2 0.86 30 3.67 15.6 236 107 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1600 1400 1800 1600 1400 54.2 0.83 30 3.75 15.9 254 113 58.7 0.86 29 3.85 16.3 262 117 60.5 0.90 28 3.88 16.5 264 118 53.4 0.77 27 3.72 15.8 251 112 57.9 0.80 26 3.82 16.2 259 116 56.8 0.75 28 3.88 16.4 268 124 61.5 0.78 27 3.98 16.8 276 128 63.3 0.81 26 4.01 17.0 279 129 57.1 0.63 23 3.84 16.2 265 123 61.8 0.65 23 3.94 16.7 273 126 60.6 0.61 24 4.01 17.0 279 132 65.6 0.63 24 4.11 17.4 288 136 67.6 0.66 23 4.14 17.5 291 137 61.0 0.47 19 3.97 16.8 277 131 66.1 0.48 18 4.08 17.2 285 135 51.9 0.89 30 3.97 16.7 265 113 56.3 0.92 30 4.07 17.2 273 116 58.0 0.97 29 4.10 17.3 275 117 51.0 0.85 28 3.93 16.6 262 112 55.3 0.88 28 4.03 17.0 270 115 52.9 0.86 30 4.05 17.1 285 120 57.4 0.89 29 4.16 17.5 294 124 59.1 0.93 28 4.20 17.7 296 125 52.2 0.80 27 4.02 17.0 282 119 56.5 0.83 27 4.13 17.4 291 122 55.4 0.78 28 4.19 17.6 301 131 60.1 0.80 28 4.30 18.1 310 135 61.9 0.84 27 4.34 18.2 313 136 55.7 0.65 24 4.15 17.5 298 130 60.4 0.67 23 4.26 17.9 307 134 59.2 0.63 24 4.33 18.2 314 139 64.1 0.65 24 4.45 18.7 323 144 66.0 0.68 23 4.48 18.9 326 145 59.6 0.48 19 4.29 18.1 310 138 64.5 0.50 19 4.41 18.6 320 142 50.7 0.91 30 4.23 18.1 301 117 54.9 0.95 30 4.34 18.5 310 121 56.6 0.99 29 4.37 18.7 313 122 49.8 0.87 28 4.19 17.9 298 116 54.0 0.90 28 4.30 18.4 307 120 51.7 0.88 30 4.32 18.5 324 125 56.0 0.91 29 4.43 19.0 334 128 57.7 0.96 28 4.47 19.1 337 130 50.9 0.82 27 4.28 18.3 321 123 NOTE: 55.2 0.85 27 4.40 18.8 331 127 63.0 0.52 19 4.70 20.1 364 148 52.7 0.93 28 4.53 19.6 350 126 53.8 0.87 27 4.64 20.0 376 134 57.5 0.71 24 4.80 20.7 398 146 61.5 0.53 19 4.96 21.4 415 155 54.1 0.79 28 4.47 19.1 342 136 58.6 0.82 28 4.58 19.6 352 140 60.4 0.86 27 4.62 19.7 356 142 57.7 0.64 24 4.62 19.7 357 145 62.6 0.67 24 4.74 20.3 368 149 64.4 0.70 23 4.78 20.4 371 151 49.5 0.94 31 4.45 19.2 343 123 53.6 0.98 30 4.57 19.8 353 127 55.2 1.00 28 4.61 19.9 357 128 50.4 0.91 30 4.56 19.7 369 131 54.6 0.94 30 4.68 20.2 380 135 56.3 0.99 28 4.72 20.4 384 136 52.8 0.82 28 4.71 20.3 389 143 57.2 0.85 28 4.84 20.8 401 147 58.9 0.89 27 4.88 21.0 405 149 56.3 0.67 25 4.87 21.0 406 152 61.0 0.69 24 5.00 21.6 419 157 62.9 0.72 23 5.05 21.8 423 158 54.4 58.2 48.6 49.7 53.1 56.7 0.66 0.50 0.90 0.84 0.69 0.51 24 19 29 27 24 19 4.43 4.58 4.42 4.52 4.67 4.83 18.9 19.6 19.1 19.5 20.1 20.8 339 353 339 365 386 402 135 143 122 130 141 151 Shaded area reflects AHRI rating conditions 58.9 0.69 23 4.55 19.4 349 139 47.0 0.98 30 4.65 20.4 386 129 50.9 1.00 29 4.77 21.0 397 133 52.4 1.00 27 4.81 21.1 401 134 46.2 0.93 28 4.61 20.2 382 128 50.0 0.97 28 4.73 20.8 394 132 47.9 0.94 30 4.76 20.9 415 137 51.9 0.98 29 4.88 21.4 428 141 53.5 1.00 27 4.93 21.6 432 143 47.2 0.87 27 4.71 20.7 411 136 51.1 0.91 27 4.84 21.3 423 140 50.2 0.85 28 4.92 21.5 438 150 54.4 0.88 28 5.05 22.1 452 154 56.0 0.93 26 5.09 22.3 456 156 50.4 0.71 24 4.88 21.3 434 148 54.6 0.74 23 5.01 21.9 447 153 * NOTE: Shaded areas is AHRI Rating Conditions IDB: Entering Indoor Dry Bulb Temperature KW = Total system power High and low pressures are measured at the liquid and suction access fittings. AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 56.6 0.85 28 3.73 15.8 241 109 MBh S/T Delta T KW AMPS HI PR LO PR 53.5 0.69 24 5.09 22.3 457 159 58.0 0.72 24 5.23 22.9 471 164 59.7 0.75 23 5.27 23.1 476 166 53.9 0.53 19 5.05 22.1 452 158 58.4 0.55 19 5.18 22.7 466 163 43.5 0.99 28 4.82 21.5 426 133 47.2 1.00 27 4.95 22.1 439 137 48.6 1.00 25 4.99 22.3 444 139 42.8 0.94 26 4.78 21.4 422 132 46.3 0.98 26 4.90 21.9 435 136 44.4 0.95 28 4.93 22.1 458 142 48.1 0.99 27 5.06 22.7 473 146 49.5 1.00 25 5.10 22.9 477 148 43.7 0.88 25 4.89 21.9 454 140 47.4 0.91 25 5.02 22.5 468 145 63 48.8 0.96 24 5.06 22.7 473 146 46.5 0.86 26 5.10 22.8 484 155 50.3 0.89 26 5.24 23.4 499 160 51.9 0.93 25 5.28 23.6 504 161 46.7 0.72 22 5.05 22.6 479 153 50.6 0.74 22 5.19 23.2 494 158 67 52.1 0.78 21 5.24 23.4 499 160 115 49.6 0.70 23 5.28 23.6 505 165 53.7 0.72 22 5.42 24.2 520 170 55.3 0.76 21 5.47 24.5 526 172 49.9 0.54 18 5.23 23.4 500 163 54.1 0.56 17 5.37 24.0 515 168 71 55.7 0.58 17 5.42 24.2 520 170 COOLING OPERATION Design Subcooling, 6 ± 2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 9 ± 2°F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MBh 58.3 59.6 63.7 68.1 57.0 58.2 62.2 66.5 55.6 56.8 60.7 64.9 54.3 55.4 59.2 63.3 51.5 52.7 56.3 60.1 47.7 S/T 0.89 0.84 0.68 0.51 0.92 0.87 0.70 0.53 0.95 0.89 0.72 0.54 1.00 0.92 0.75 0.56 1.00 0.95 0.77 0.58 1.00 Delta T 27 25 22 18 27 26 22 18 27 26 22 18 28 26 23 18 26 26 22 18 24 1800 KW 3.77 3.85 3.98 4.11 4.07 4.16 4.30 4.45 4.34 4.43 4.58 4.74 4.57 4.68 4.84 5.00 4.77 4.88 5.05 5.23 4.95 AMPS 16.0 16.3 16.8 17.4 17.2 17.5 18.1 18.7 18.5 19.0 19.6 20.3 19.8 20.2 20.8 21.6 21.0 21.4 22.1 22.9 22.1 HI PR 243 262 276 288 273 294 310 323 310 334 352 368 353 380 401 419 397 428 452 471 439 LO PR 110 117 128 136 116 124 135 144 121 128 140 149 127 135 147 157 133 141 154 164 137 MODEL: GPC1460H41A* COOLING PERFORMANCE DATA GPC1460H41A* COOLING PERFORMANCE DATA PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb temperatures increase, a slight increase will occur in indoor air temperature drop (Delta T). Low and high side pressures and power will not change. 2. As indoor CFM decreases, a slight increase will occur in indoor temperature drop (Delta T). A slight decrease will occur in low and high side pressures and power. A properly operating unit should be within plus or minus 3 degrees of the typical (Delta T) value shown. A properly operating unit should be within plus or minus 7 PSIG of the HI PR shown. A properly operating unit should be within plus or minus 3 PSIG of the LO PR shown. A properly operating unit should be within plus or minus 3 Amps of the typical value shown. 25 WIRING DIAGRAMS GPC14[24-60]H41A* PU NOTE #3 BK BK 1 C 2 PU PU 3 BL 208 240 BK BL 24V RD C WARNING HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. BL BK BK 2 0 8 2 4 0 / 1 / L2 T2 RD SEE NOTE 5 L1 T1 RD YL GND GR BK 60 RD RD YL PU LVJB YL RD BR WH BL YL H BL C F RCCF GR WH GR PLF 3 6 9 2 5 8 1 4 7 BR PU YL RD GR WH Y R G W1 BR BL W2 C ++ BR RD BK SA (IF USED) SEE NOTE 4 CONTROL BOX RD BK YL T H E R M O S T A T PU BR BK WH GR YL S C R C L G N 1 2 3 4 5 CM COMP HPS WH SEE NOTE 2 EM L1 L2 SUPPLY VOLTAGE 208-240/1/60 T2 C C R T1 C COMP C S H COMPONENT LEGEND C CM COMP EM GND LVJB PLF RCCF RCCF F S.A. SA TR HPS CM NOTE #4 IF USED NOTE #2 L N EM 1 G 3 2 208-240 NOTE #4 3 2 CONTACTOR CONDENSER MOTOR COMPRESSOR EVAPORATOR MOTOR EQUIPMENT GROUND LOW VOLTAGE JUNCTION BOX FEMALE PLUG / CONNECTOR RUN CAPACITOR FOR COMPRESSOR AND FAN START ASSIST TRANSFORMER HIGH PRESSURE SWITCH FACTORY WIRING LINE VOLTAGE LOW VOLTAGE OPTINAL HIGH VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE CODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PU PURPLE RD RED WH WHITE YL YELLOW 1 TR 24V NOTES: 1 EM C 2 3 SEE NOTE #2 4 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW LEADS FROM EM "2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE ENERGIZED, THE HIGHER SPEED SETTING IS USED. 3. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER. 4. START ASSIST FACTORY EQUIPED WHEN REQUIRED 5. USE COPPER CONDUCTORS ONLY. ++ USE N.E.C. CLASS 2 WIRE 5 6 PLF C HPS R W2 W1 Y G SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION C THERMOSTAT 208-240/1/60 0140G00871 REV. B Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 26