Download Emerson T205B Data Sheet

Transcript
Bulletin 74.1:T205B
Table 2. Outlet (Control) Pressure Ranges and Spring Information
Outlet (Control) Pressure Range
Inch w.c.
mbar
1.0 to 2.5(1)(2)
2.5 to 7.0(2)
7.0 to 16.0
0.5 to 1.2 psig
1.2 to 2.5 psig
2.5 to 4.5 psig
4.5 to 7 psig
2.5 to 6.2(1)(2)
6.2 to 17(2)
17 to 40
34 to 83
83 to 172
0.17 to 0.31 bar
0.31 to 0.48 bar
Spring Wire Diameter
Spring Color
Orange
Red
Unpainted
Yellow
Green
Light Blue
Black
Spring Free Length
Inch
mm
Inch
mm
0.072
0.085
0.105
0.114
0.156
0.187
0.218
1.8
2.2
2.7
2.9
4.0
4.8
5.5
3.25
3.63
3.75
4.31
4.06
3.94
3.98
82.6
92.2
95.2
109
103
100
101
1. Do not use Fluorocarbon (FKM) diaphragm with this spring at diaphragm temperatures lower than 60°F / 16°C.
2. To achieve the published outlet pressure range the spring case must be installed pointing down.
Table 3. Available Construction and Trim Materials
Available construction materials
Body and
Casing
Guide
Insert
Gray cast iron,
WCC Carbon
Steel,
or CF8M/
CF3M
Stainless
steel(1)
Diaphragm
Head
316
Stainless
steel
304
Stainless
steel
Lever
Assembly
and Bias
Spring
302
Stainless
steel
Available trim options
Stem
Trim Option
Diaphragm Material
Code
Disk and O-ring
Material
Operating Temperature
Ranges
Standard
Fluorinated Ethylene
Propylene (FEP)
Nitrile (NBR)
-20 to 180°F /
-29 to 82°C
NN
Nitrile (NBR)
Nitrile (NBR)
-40 to 180°F /
-40 to 82°C
VV
Fluorocarbon (FKM)
Fluorocarbon (FKM)
40 to 300°F /
4 to 149°C
TV
Fluorinated Ethylene
Propylene (FEP)
Fluorocarbon (FKM)
40 to 180°F /
4 to 82°C
TK
Fluorinated Ethylene
Propylene (FEP)
Perfluoroelastomer
(FFKM)
0 to 180°F /
-18 to 82°C
TE
Fluorinated Ethylene
Propylene (FEP)
Ethylene Propylene
Diene (EPDM)
-20 to 180°F /
-29 to 82°C
Nitronic 60
®
1. Pipe nipples and flanges are 316 Stainless steel for flanged body assemblies.
Nitronic® is a registered trademark of AK Steel Corporation.
Table 4. Type T205B Flow and Sizing Coefficients
ORIFICE SIZE
REGULATING
WIDE-OPEN
Inch
mm
Cg
Cv
C1
Cg
Cv
C1
3/8
9.5
98
2.8
34.6
101
2.9
34.6
Table 5. Flow Rate Conversion
Multiply Maximum Pump Rate In
BY
U.S. GPM
8.021
U.S. GPH
0.1337
Barrels/hour
5.615
Barrels/day
0.2340
TO OBTAIN
SCFH air required(1)
1. To convert to Nm3/h multiply SCFH by 0.0268.
5