Download Emerson A11 Data Sheet
Transcript
Product Bulletin A11 Valve 21.1:A11 May 2013 D500203X012 Table 19. Maximum Allowable Shutoff Pressure Drops, CL600(1) TRIM NUMBER TEMP RANGE NPS 3 NPS 4 NPS 6 NPS 8 NPS 10 NPS 12 NPS 14 NPS 16 NPS 18 NPS 20 NPS 24 Bar _C -46 to 38 98.9 103.1 103.4 103.4 99.1 103.4 103.4 103.4 103.4 103.4 60.9 38 to 93 75.8 75.8 75.8 75.8 75.8 75.8 75.8 75.8 75.8 75.8 60.9 93 to 121 41.4 41.4 41.4 41.4 41.4 41.4 41.4 41.4 41.4 41.4 41.4 121 to 149 6.9 6.9 6.9 6.9 6.9 6.9 6.9 6.9 6.9 6.9 6.9 -46 to 38 95.0 100.4 103.4 103.4 98.0 92.2 103.4 103.4 103.4 94.8 55.2 38 to 232 82.3 87.6 82.1 95.1 86.9 74.1 103.4 103.4 103.4 94.8 55.2 -46 to 38 93.1 100.1 103.4 103.4 98.1 87.1 103.4 103.4 103.4 84.7 46.2 38 to 93 79.5 94.3 96.5 96.5 93.0 79.2 96.5 96.5 96.5 84.7 46.2 93 to 121 62.1 62.1 62.1 62.1 62.1 62.1 62.1 62.1 62.1 62.1 46.2 121 to 149 20.7 20.7 20.7 20.7 20.7 20.7 20.7 20.7 20.7 20.7 20.7 -46 to 38 91.8 98.4 75.4 103.4 95.6 65.7 103.4 103.4 93.3 67.2 38.1 38 to 343 62.1 78.9 51.4 76.5 82.2 48.4 101.8 83.2 93.3 67.2 38.1 343 to 427 58.7 75.1 48.8 73.3 80.5 46.5 98.5 80.5 93.3 67.2 38.1 343 to 427 58.7 75.1 48.8 73.3 80.5 46.5 98.5 80.5 93.3 67.2 38.1 514H(2), 516H 427 to 538 97.8 103.4 83.6 103.4 101.2 71.7 103.4 103.4 93.4 67.2 38.1 517C -196 to 163 500 502 504 506 514H, 516H 517C(3) TRIM NUMBER Consult your Emerson Process Management sales office. -196 to -129 88.4 92.3 100.2 98.7 89.9 103.4 103.4 103.4 103.4 103.4 78.3 -129 to -46 79.6 83.2 90.3 89.1 81.6 94.8 102.3 103.4 103.4 103.4 78.3 -46 to 38 67.6 70.7 76.7 76.3 70.3 77.6 88.6 93.1 94.5 103.4 78.3 38 to 149 61.2 64.1 69.5 69.4 64.3 66.7 81.2 85.1 86.3 96.5 78.3 Psi _F -50 to 100 1435 1495 1500 1500 1437 1500 1500 1500 1500 1500 883 100 to 200 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 883 200 to 250 600 600 600 600 600 600 600 600 600 600 600 250 to 300 100 100 100 100 100 100 100 100 100 100 100 -50 to 100 1378 1456 1500 1500 1422 1337 1500 1500 1500 1375 800 100 to 450 1194 1270 1191 1380 1260 1075 1500 1500 1500 1375 800 -50 to 100 1350 1453 1500 1500 1422 1264 1500 1500 1500 1229 670 100 to 200 1153 1368 1400 1400 1349 1148 1400 1400 1400 1229 670 200 to 250 900 900 900 900 900 900 900 900 900 900 670 250 to 300 300 300 300 300 300 300 300 300 300 300 300 -50 to 100 1331 1427 1093 1500 1401 953 1500 1500 1353 974 553 100 to 650 900 1144 746 1110 1192 702 1477 1206 1353 974 553 650 to 800 852 1089 708 1064 1167 675 1429 1168 1353 974 553 514H, 516H 650 to 800 852 1089 708 1064 1167 675 1429 1168 1353 974 553 514H(2), 516H 800 to 1000 1418 1500 1213 1500 1468 1040 1500 1500 1354 974 553 -320 to -200 1282 1339 1454 1431 1304 1500 1500 1500 1500 1500 1135 -200 to -50 1155 1206 1309 1293 1184 1375 1484 1500 1500 1500 1135 -50 to 100 980 1025 1113 1106 1020 1126 1285 1350 1371 1500 1135 100 to 300 887 929 1008 1006 933 967 1178 1234 1251 1400 1135 500 502 504 506 517C 517C(3) -320 to 325 Consult your Emerson Process Management sales office. 1. Consult your Emerson Process Management sales office if higher pressure drops are required. 2. Trim 514H with optional N07718 shaft for temperatures up to 482_C (1000_F). 3. Trim 517C with optional CTFE cryogenic seal without backup ring. 18