Download Emerson A11 Data Sheet

Transcript
Product Bulletin
A11 Valve
21.1:A11
May 2013
D500203X012
Table 19. Maximum Allowable Shutoff Pressure Drops, CL600(1)
TRIM
NUMBER
TEMP RANGE
NPS 3
NPS 4
NPS 6
NPS 8
NPS 10
NPS 12
NPS 14
NPS 16
NPS 18
NPS 20
NPS 24
Bar
_C
-46 to 38
98.9
103.1
103.4
103.4
99.1
103.4
103.4
103.4
103.4
103.4
60.9
38 to 93
75.8
75.8
75.8
75.8
75.8
75.8
75.8
75.8
75.8
75.8
60.9
93 to 121
41.4
41.4
41.4
41.4
41.4
41.4
41.4
41.4
41.4
41.4
41.4
121 to 149
6.9
6.9
6.9
6.9
6.9
6.9
6.9
6.9
6.9
6.9
6.9
-46 to 38
95.0
100.4
103.4
103.4
98.0
92.2
103.4
103.4
103.4
94.8
55.2
38 to 232
82.3
87.6
82.1
95.1
86.9
74.1
103.4
103.4
103.4
94.8
55.2
-46 to 38
93.1
100.1
103.4
103.4
98.1
87.1
103.4
103.4
103.4
84.7
46.2
38 to 93
79.5
94.3
96.5
96.5
93.0
79.2
96.5
96.5
96.5
84.7
46.2
93 to 121
62.1
62.1
62.1
62.1
62.1
62.1
62.1
62.1
62.1
62.1
46.2
121 to 149
20.7
20.7
20.7
20.7
20.7
20.7
20.7
20.7
20.7
20.7
20.7
-46 to 38
91.8
98.4
75.4
103.4
95.6
65.7
103.4
103.4
93.3
67.2
38.1
38 to 343
62.1
78.9
51.4
76.5
82.2
48.4
101.8
83.2
93.3
67.2
38.1
343 to 427
58.7
75.1
48.8
73.3
80.5
46.5
98.5
80.5
93.3
67.2
38.1
343 to 427
58.7
75.1
48.8
73.3
80.5
46.5
98.5
80.5
93.3
67.2
38.1
514H(2),
516H
427 to 538
97.8
103.4
83.6
103.4
101.2
71.7
103.4
103.4
93.4
67.2
38.1
517C
-196 to 163
500
502
504
506
514H,
516H
517C(3)
TRIM
NUMBER
Consult your Emerson Process Management sales office.
-196 to -129
88.4
92.3
100.2
98.7
89.9
103.4
103.4
103.4
103.4
103.4
78.3
-129 to -46
79.6
83.2
90.3
89.1
81.6
94.8
102.3
103.4
103.4
103.4
78.3
-46 to 38
67.6
70.7
76.7
76.3
70.3
77.6
88.6
93.1
94.5
103.4
78.3
38 to 149
61.2
64.1
69.5
69.4
64.3
66.7
81.2
85.1
86.3
96.5
78.3
Psi
_F
-50 to 100
1435
1495
1500
1500
1437
1500
1500
1500
1500
1500
883
100 to 200
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
883
200 to 250
600
600
600
600
600
600
600
600
600
600
600
250 to 300
100
100
100
100
100
100
100
100
100
100
100
-50 to 100
1378
1456
1500
1500
1422
1337
1500
1500
1500
1375
800
100 to 450
1194
1270
1191
1380
1260
1075
1500
1500
1500
1375
800
-50 to 100
1350
1453
1500
1500
1422
1264
1500
1500
1500
1229
670
100 to 200
1153
1368
1400
1400
1349
1148
1400
1400
1400
1229
670
200 to 250
900
900
900
900
900
900
900
900
900
900
670
250 to 300
300
300
300
300
300
300
300
300
300
300
300
-50 to 100
1331
1427
1093
1500
1401
953
1500
1500
1353
974
553
100 to 650
900
1144
746
1110
1192
702
1477
1206
1353
974
553
650 to 800
852
1089
708
1064
1167
675
1429
1168
1353
974
553
514H,
516H
650 to 800
852
1089
708
1064
1167
675
1429
1168
1353
974
553
514H(2),
516H
800 to 1000
1418
1500
1213
1500
1468
1040
1500
1500
1354
974
553
-320 to -200
1282
1339
1454
1431
1304
1500
1500
1500
1500
1500
1135
-200 to -50
1155
1206
1309
1293
1184
1375
1484
1500
1500
1500
1135
-50 to 100
980
1025
1113
1106
1020
1126
1285
1350
1371
1500
1135
100 to 300
887
929
1008
1006
933
967
1178
1234
1251
1400
1135
500
502
504
506
517C
517C(3)
-320 to 325
Consult your Emerson Process Management sales office.
1. Consult your Emerson Process Management sales office if higher pressure drops are required.
2. Trim 514H with optional N07718 shaft for temperatures up to 482_C (1000_F).
3. Trim 517C with optional CTFE cryogenic seal without backup ring.
18