Download Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Messages Reference Guide
Transcript
Table 3-4. Storage Management Messages (continued) Event ID Description Severity Cause and Action Related SNMP Alert Trap Information Numbers 2094 Predictive Failure reported. Warning / Non-critical Cause: The physical disk is predicted to fail. Many physical disks contain Self Monitoring Analysis and Reporting Technology (SMART). When enabled, SMART monitors the health of the disk based on indications such as the number of write operations that have been performed on the disk. Clear Alert 903 Number: None Related Alert Number: None LRA Number: 2070 Action: Replace the physical disk. Even though the disk may not have failed yet, it is strongly recommended that you replace the disk. If this disk is part of a redundant virtual disk, perform the Offline task on the disk; replace the disk; the rebuild starts automatically. NOTE: If you put the drive in a different slot, you need to assign it as a hot spare for the rebuild to start automatically. Storage Management Message Reference 91