Download Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Messages Reference Guide
Transcript
Table 3-4. Storage Management Messages (continued) Event ID Description Severity Cause and Action 2112 Enclosure was Critical / Cause: The physical shut down Failure / Error disk enclosure is either hotter or cooler than the maximum or minimum allowable temperature range. Related SNMP Alert Trap Information Numbers Clear Alert 854 Number: None Related Alert Number: None Action: Check for factors that may cause LRA overheating or excessive Number: cooling. For example, 2091 verify that the enclosure fan is working. You should also check the thermostat settings and examine whether the enclosure is located near a heat source. Make sure the enclosure has enough ventilation and that the room temperature is not too hot or too cold. See the enclosure documentation for more diagnostic information. 104 Storage Management Message Reference