Download Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Messages Reference Guide
Transcript
Table 4-3. Fan Sensor Events (continued) Event Message Severity Cause <Sensor Name/Location> Information The fan specified by <Sensor Name/ Fan Redundancy sensor Location> may have started redundancy regained functioning again and hence, the redundancy has been regained. Fan <number> RPM is less than the lower warning threshold. Warning The speed of the specified fan might not provide enough cooling to the system. Fan <number> RPM is less than the lower critical threshold. Critical The speed of the specified fan is not sufficient to provide enough cooling to the system. Fan <number> RPM is Warning greater than the upper warning threshold. The speed of the specified fan exceeded the warning threshold. Fan <number> RPM is Critical greater than the upper critical threshold. The speed of the specified fan exceeded the critical threshold. Fan <number> RPM is outside of range. Critical Fan <number> RPM is within range. Information The speed of the specified fan is operating in a normal range. Fan <number> is removed. Critical Fan <number> was inserted. Information A fan was added. Fan <number> is present. Information The total number of fans present. Fan <number> is absent. Critical The fans are redundant. Information One or more fans may have started functioning or installed and the redundancy has been regained. 252 The speed of the specified fan might not provide enough cooling to the system. A required fan was removed. A required fan is missing. System Event Log Messages for IPMI Systems