Severity
In the context of configuring events, severity determines how severe an event
is, before Server Administrator notifies you of the event for a component
type. When there are multiple components of the same type in the same
system chassis, you can specify whether you want notification for event
severity according to the number of the component by using the index=<n>
parameter. Table 4-28 lists the valid severity parameters.
Table 4-28. System Event Severity Parameters
Command
Result
omconfig system events type=
<component name> severity=info
or
omconfig servermodule events
type=<component name>
severity=info
omconfig system events type=
<component name> severity=
warning
or
omconfig servermodule events
type=<component name>
severity=warning
omconfig system events type=
<component name> severity=
critical
or
omconfig servermodule events
type=<component name>
severity=critical
omconfig system events type=
<component name> severity=
none
or
omconfig servermodule events
type=<component name>
severity=none
Enables notification Least restrictive form of
for informational, event notification.
warning, and critical
events.
170
Description
Enables notification Omits informational event
for warning and
notification, for example,
critical events.
when a component returns
to normal status.
Enables notification Restrictive form of event
for critical events
notification.
only.
Disables event
notification.
No event notification.