Download Bell DBA-8Z User's Manual

Transcript
Digibell Vandal Resistant Systems
CABLE SUPPLEMENT
1 Entrance
Zone isolation (DBA-8Z)
Daisy-chained Zone isolators
Power supplies at each floor level
PD-250 Issue 1
Cable legends
1x
CAT5
8 Cores of CAT5/5e
2
4
2 Cores of CAT5/5e
Optional cores depending
on feature required
bell
system
www.bellsystem.co.uk
Digibell
PD-250 Issue 1
System
Part 1
Note
1. Contact Technical support for more than 1 phone per flat.
2. Maximum of 300m between the furthest 2 points.
3. All control equipment must be located in a protected indoor environment.
4. One DBA-8Z Phone Isolator per 8 flats.
To Floor
2
1x
CAT5
8 Flats/Phones
01
EF 2
7 89 A
7 8 9A
7 8 9A
340C
PSU
1x
CAT5
3m Max.
3m Max.
1x
CAT5
50m
Max.
4
Mo
1
ON
ON
13:44 56
ON
AUTO
OFF
P
MANUAL
CK
MIN
CLO
TIME
R
HOUR
DAY
BSD-DIG
2 cores
of 1.5mm2
TS2000-BST
Time Clock
(Trades)
PS4
PS4
PSU
50m
Max.
3m
Max.
3x
CAT5
Cores of
CAT5
0.5A 4
1.0A 8
2
Descriptions
DBA-8Z Zonal Isolator/Distributor
BSD-DIG Digital Door Controller
TS2000-BST Time Clock
PS4 Power Supply, 13.8VDC, 4A
340C Power Supply, 13.8VDC, 1.5A
2 cores
of 1.5mm2
01
EF 2
3456
340C
PSU
1x
CAT5
DBA-8Z
01
EF 2
3456
To distribution
of next 16
100m
Max.
BCD
BC D
DBA-8Z
2 cores
of 1.5mm2
3456
3456
01
EF 2
DBA-8Z
Flat 8
1x
CAT5
1x
CAT5
100m
Max.
BC D
DBA-8Z
8 Flats/
Phones
1x
CAT5
1x
CAT5
8 Flats/Phones
Flat 1
7 89 A
Floor 1
8 Flats/
Phones
Flat 24
BCD
Flat 17
Exit
Button
Entrance
www.bellsystem.co.uk
Lock
release
Digibell
PD-250 Issue 1
System
Part 2
Note
1. Contact Technical support for more than 1 phone per flat.
2. Maximum of 300m between the furthest 2 points.
3. All control equipment must be located in a protected indoor environment.
4. One DBA-8Z Phone Isolator per 8 flats.
To next
Floor
1x
CAT5
8 Flats/Phones
Flat 81
1x
CAT5
1x
CAT5
DBA-8Z
DBA-8Z
DBA-8Z
2 cores
of 1.5mm2
100m
Max.
DBA-8Z
01
EF 2
7 89 A
7 89 A
7 8 9A
1x
CAT5
1x
CAT5
7 8 9A
8 Flats/
Phones
340C
PSU
1x
CAT5
Flat 56
3456
8 Flats/Phones
Flat 49
Floor 2
3m Max.
1x
CAT5
2 cores
of 1.5mm2
01
EF 2
3456
BC D
3456
3456
01
EF 2
340C
PSU
To distribution
of next 16
Flat 72
1x
CAT5
1x
CAT5
100m
Max.
01
EF 2
BC D
8 Flats/
Phones
8 Flats/Phones
BCD
Floor 3
Flat 65
BC D
8 Flats/
Phones
Flat 88
3m Max.
Flat 33
8 Flats/
Phones
8 Flats/Phones
1x
CAT5
1x
CAT5
100m
Max.
Flat 40
100m
Max.
1x
CAT5
1x
CAT5
3m Max.
BC D
1x
CAT5
BC D
BC D
7 89 A
7 8 9A
340C
PSU
2 cores
of 1.5mm2
01
EF 2
3456
01
EF 2
3456
To distribution
of next 16
DBA-8Z
01
EF 2
7 89 A
BC D
DBA-8Z
2 cores
of 1.5mm2
34 56
34 56
01
EF 2
DBA-8Z
7 89A
DBA-8Z
340C
PSU
3m Max.
1x
CAT5
From
Floor 1