Download ADC H2TU-C-231 User's Manual
Transcript
LTPH-UM-1109-01, Issue 1 Installation INSTALLATION Upon receipt of the equipment, inspect the contents for signs of damage. If the equipment has been damaged in transit, immediately report the extent of damage to the transportation company and to ADC. H2TU-C-231 HiG HLU ain -4 LIN 31 EU N IT CO Shelf Pa irG ain Figure 2. Installing the H2TU-C-231 List 2 into a Shelf When installing an H2TU-C 231 in a chassis, be sure to wear an antistatic wrist strap. Avoid touching components on the circuit board. To comply with the intrabuilding wiring requirements of GR-1089 CORE, Section 4.5.9, the shields of the ABAM-type cables that connect the H2TU-C-231 List 2 DSX-1 output ports to the cross-connect panel must be grounded at both ends. 1 Align the H2TU-C with the enclosure slot guides and slide the unit in. Push the unit back until it touches the backplane card-edge connector and the retaining latch on the front panel opens. 2 Place your thumbs on the front panel and push the H2TU-C into the slot guides until the retaining latch closes. This indicates that the card is properly seated. H2TU-C-231 List 2 January 9, 2002 7