Download ELK 960
Transcript
SAMPLE APPLICATIONS AND WIRING DIAGRAMS (Set jumpers as shown) - DOOR STRIKE HOLD TIMER 1 + JP5 N/O Pushbutton + - + N/O BEGIN COM - LED DOOR PROP ALARM TIMER 22K Ohm Resistor - N/C JP5 N/O N/C 120V LIGHT B MIN REPEAT 1-SHOT END BEGIN TRIGGER MODE K1 COM A LED TGR - + SEC JP3 BEGIN TRIGGER MODE K1 Hot 120VAC Supply TRIGGER POLARITY JP2 N/C END + JP1 Delay Timer 1-SHOT JP3 COM TIME 1 - 60 ELK-960 JP5 N/O AUTOMATIC LIGHT CONTROL R3 TGR N/C CONTACT ON DOOR 4 + COM REPEAT JP2 - + JP4 + MIN TRIGGER POLARITY + + - - SEC JP1 R3 Delay Timer - 12 Volts DC Power Supply Motion Detector TIME 1 - 60 ELK-960 SIREN BEGIN Used to extend the release time of an access control device or to manually activate a door maglock release device. The trigger is activated by a contact closure or a N/O pushbutton and the door maglock remains released (door open) after the button is released for the delay time set up in the ELK-960. - 3 + END B JP4 Used to extend the release time of an access control device or to manually activate a door strike release device. The trigger is activated by a contact closure or a N/O pushbutton and the door strike remains activated (door open) after the button is released for the delay time set up in the ELK-960. - 1-SHOT A B LED 12 Volts DC Power Supply REPEAT TRIGGER MODE K1 N/C A MIN JP3 N/C 12/24V MAGLOCK END TRIGGER MODE K1 TGR - SEC JP2 COM + TRIGGER POLARITY JP1 N/O Delay Timer R3 N/O Pushbutton 1-SHOT JP5 JP3 + TIME 1 - 60 ELK-960 REPEAT JP2 TGR MAGLOCK RELEASE TIMER MIN TRIGGER POLARITY - + 2 + SEC JP1 - R3 Delay Timer 12/24V DOOR STRIKE - TIME 1 - 60 ELK-960 + 12/24 Volts DC Power Supply - 12/24 Volts DC Power Supply A B JP4 LED JP4 Neutral Delay is started when the door is opened. If the door remains opened after the time delay has expired the relay will turn on and remain on until the door is closed. If the door is closed before the time delay expires the ELK-960 is reset awaiting another input from the door contact. + ARMED OUTPUT 12V AUX - + EXIT DELAY SHUNT TIMER TIME 1 - 60 ELK-960 JP5 1-SHOT - N/C N/C CONTACT BEGIN N/C - JP2 Delay Timer BEGIN + - JP4 Useful for adding a cut-off timer to a control panel that does not have one. It can also be used to shorten the cut-off timer for a control with no adjustable timer. 9 + N/C REPEAT 1-SHOT END BEGIN A + B LED JP4 Converts a steady output to pulsing, suitable for flashing a light or pulsing an audible device. Note: Alarm output must be capable of supplying enough current to drive the bell and light. 1-SHOT BEGIN A - B JP4 #1 TGR JP5 120VAC Supply Hot N/O COM 120V LIGHT N/C K1 TRIGGER MODE SEC MIN REPEAT 1-SHOT END BEGIN A B LED Neutral - + JP3 TRIGGER MODE REPEAT END + TRIGGER POLARITY JP2 JP3 K1 TIME 1 - 60 Delay Timer MIN JP1 JP2 N/O SEC R3 JP5 - + JP1 TGR LED - MIN TRIGGER MODE K1 COM ELK-960 R3 + TRIGGER POLARITY N/C - - + N/O TIME 1 - 60 Delay Timer COM JP5 SEC USING TWO 960'S TO DELAY THEN THEN TOGGLE A RELAY ELK-960 N/O SWITCH TGR - - 12V LIGHT or LED 12V Bell or Siren B 12 Volts DC Power Supply TRIGGER POLARITY JP3 END A LED + 1-SHOT JP3 N/C TIME 1 - 60 ELK-960 REPEAT TRIGGER MODE K1 COM + MIN JP2 JP5 BEGIN BELL OR LIGHT FLASHER JP1 TGR - + N/O + 12V ALARM OUTPUT R3 TRIGGER POLARITY END JP4 8 CONTROL PANEL SEC JP1 R3 + 1-SHOT When contact opens, relay is turned on which causes instant zone violation. Contact reclosure will cancel trigger applied by resistor. Delay starts when contact closes. Relay turns off and zone restores after delay time expires. TIME 1 - 60 Delay Timer REPEAT B ALARM CUT-OFF TIMER ELK-960 MIN A LED - + SEC TRIGGER MODE K1 COM JP4 7 12V ALARM OUTPUT - JP5 B LED CONTROL PANEL 12V Bell or Siren TGR - + N/O A Provides an exit delay to an otherwise instant alarm loop. The ELK-960 is triggered by the control's Armed output. The door contact is then shunted by the relay contacts. After the user has exited and the delay time has expired, the door contact is restored into the loop. - + TRIGGER POLARITY JP3 END TRIGGER MODE K1 Delay Timer 22K Ohm Resistor REPEAT JP3 COM TIME 1 - 60 ELK-960 MIN JP2 N/O 6 JP2 TGR - + + JP1 TRIGGER POLARITY - INSTANT ACTIVATION OF ZONE WITH DELAYED RESTORAL R3 + 12V AUX SEC JP1 R3 Delay Timer N/C CONTACT ON EXIT DOOR CONTROL PANEL CLOSED ZONE - 5 CONTROL PANEL CLOSED ZONE INPUT For turning on an interior or exterior light with a motion detector. When motion is detected, the ELK-960 is triggered and the light is turned on. The amount of time the light remains on after the detector resets is adjustable. Delay time will automatically restart each time the motion detector activates. JP4 #2 Used for delaying a trigger then toggling a relay on/off. ELK-960 #1 starts a time delay when the N/O switch is closed. When 960 #1's time delay expires, 960 #2 is triggered turning it's relay on for the time delay setting , then turning the relay off. (toggle) To sumarize: fire trigger on #1, waits, turns on #2's relay, waits, then turns relay off.