Download SUPER ®

Transcript
SUPERSERVER 6027R-N3RF4+/6027R-N3RFT+ User's Manual
2-4 Installing the System into a Rack
This section provides information on installing the server into a rack unit with the
rack rails provided. If the system has already been mounted into a rack, you can
skip ahead to Sections 2-5 and 2-6. There are a variety of rack units on the market,
which may mean the assembly procedure will differ slightly. You should also refer to
the installation instructions that came with the rack unit you are using.
Separating the Sections of the Rack Rails
The chassis package includes two rail assemblies in the rack mounting kit. Each
assembly consists of two sections: an inner fixed chassis rail that secures directly
to the server chassis and an outer fixed rack rail that secures directly to the rack
itself.
Figure 2-1. Separating the Rack Rails
Rail Assembly
1
F.
Separating the Inner and Outer Rails
SCREW
1. Locate the rail assembly in the chassis
packaging.
Extending the Rails
12
2. Extend the rail assembly by pulling it
outward.
2
1
3. Press the quick-release tab.
13
14
QuickRelease Tab
4. Separate the inner rail extension from
the outer rail assembly.
Separating
the Inner Rail
Extension
SCREW
screw the handles the
outer rails for secure
purpose if necessary
2-4