Download SUPER ®
Transcript
SUPERSERVER 6027R-N3RF4+/6027R-N3RFT+ User's Manual 2-4 Installing the System into a Rack This section provides information on installing the server into a rack unit with the rack rails provided. If the system has already been mounted into a rack, you can skip ahead to Sections 2-5 and 2-6. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. You should also refer to the installation instructions that came with the rack unit you are using. Separating the Sections of the Rack Rails The chassis package includes two rail assemblies in the rack mounting kit. Each assembly consists of two sections: an inner fixed chassis rail that secures directly to the server chassis and an outer fixed rack rail that secures directly to the rack itself. Figure 2-1. Separating the Rack Rails Rail Assembly 1 F. Separating the Inner and Outer Rails SCREW 1. Locate the rail assembly in the chassis packaging. Extending the Rails 12 2. Extend the rail assembly by pulling it outward. 2 1 3. Press the quick-release tab. 13 14 QuickRelease Tab 4. Separate the inner rail extension from the outer rail assembly. Separating the Inner Rail Extension SCREW screw the handles the outer rails for secure purpose if necessary 2-4