Download Sun Fire X4170 M2 Server Service Manual

Transcript
FIGURE 4-11
4.4.4
Installing a PCIe Filler Panel
Install PCIe Card
1. Unpack the replacement PCIe card and place it on an antistatic mat.
2. Locate the proper PCIe slot for the card you are replacing.
3. If necessary, review the PCIe card guidelines to plan your installation.
See Section 4.4.2, “PCIe Card Configuration Guidelines” on page 4-19 for
additional information.
4. Remove the PCIe riser.
See Section 4.3, “Servicing PCIe Risers” on page 4-13.
5. Insert the PCIe card into the slot PCIe riser (FIGURE 4-12 [1]).
6. Place the PCIe riser into the motherboard and tighten the captive Phillips screw
securing the riser to the motherboard [2].
7. If necessary, remove the PCI slot filler panel from the back panel crossbar.
Chapter 4
Servicing Motherboard Components
4-21