3-3-2. POWER OVP (RED 2 Times blink)
This indicates OVP (Over Voltage Protection) of GF1(GF2) board.
12V line or 6.5Vline on GF1(GF2) board is over-voltage.
TV Micro (on AG board) pin139 detects OVP ERR and shuts down chassis power to
Stand-by status.
TV Micro #139
Normal condition : Low / Error case : High
Replace GF1(GF2) board.
3-3-3. POWER ERROR (RED 3 Times blink)
This indicates POWER Error, Low B error of 12V from GF1(GF2) board. TV Micro
(on AG board) pin150 detects POWER_ERR and shuts down chassis power to Standby status.
TV Micro #150
Normal condition : High / Error case : Low
- Check 12V at CN002 #1#2 on AG board. And F200 on AG has 12V or not
- Check GF1(GF2) board.
KLV-40/46/52W300A (CH)